Source author record

Stefan Vogt

Stefan Vogt appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2022arXiv

Ptychopy: GPU framework for ptychographic data analysis

X-ray ptychography imaging at synchrotron facilities like the Advanced Photon Source (APS) involves controlling instrument hardwares to collect a set of diffraction patterns from overlapping coherent illumination spots on extended samples, managing data storage, reconstructing ptychographic images from acquired diffraction patterns, and providing the visualization of results and feedback. In addition to the complicated workflow, ptychography instrument could produce up to several TB's of data per second that is needed to be processed in real time. This brings up the need to develop a high performance, robust and user friendly processing software package for ptychographic data analysis. In this paper we present a software framework which provides functionality of visualization, work flow control, and data reconstruction. To accelerate the computation and large datasets process, the data reconstruction part is implemented with three algorithms, ePIE, DM and LSQML using CUDA-C on GPU.

preprint2020arXiv

A transportable interrogation laser system with an instability of $\mathrm{mod}\,σ_{\rm y} = 3\times10^{-16}$

We present an interrogation laser system for a transportable strontium lattice clock operating at 698 nm, which is based on an ultra-low-expansion glass reference cavity. Transportability is achieved by implementing a rigid, compact, and vibration insensitive mounting of the 12 cm-long reference cavity, sustaining shocks of up to 50 g. The cavity is mounted at optimized support points that independently constrain all degrees of freedom. This mounting concept is especially beneficial for cavities with a ratio of length $L$ over diameter $D$ $L/D>1$. Generally large $L$ helps to reduce thermal noise-induced laser frequency instability while small $D$ leads to small cavity volume. The frequency instability was evaluated, reaching its thermal noise floor of $\mathrm{mod}\,σ_{\rm y} \approx 3 \times 10^{-16}$ for averaging times between 0.5 s and 10 s. The laser system was successfully operated during several field studies.

preprint2015arXiv

8E-17 fractional laser frequency instability with a long room-temperature cavity

We present a laser system based on a 48 cm long optical glass resonator. The large size requires a sophisticated thermal control and optimized mounting design. A self balancing mounting was essential to reliably reach sensitivities to acceleration of below $Δν/ ν$ < 2E-10 /g in all directions. Furthermore, fiber noise cancellations from a common reference point near the laser diode to the cavity mirror and to additional user points (Sr clock and frequency comb) are implemented. Through comparison to other cavity-stabilized lasers and to a strontium lattice clock an instability of below 1E-16 at averaging times from 1 s to 1000 s is revealed.

preprint2014arXiv

A strontium lattice clock with $3 \times 10^{-17}$ inaccuracy and its frequency

We have measured the absolute frequency of the optical lattice clock based on $^{87}$Sr at PTB with an uncertainty of $3.9\times 10^{-16}$ using two caesium fountain clocks. This is close to the accuracy of today's best realizations of the SI second. The absolute frequency of the 5s$^2$ $^1$S$_0$-5s5p $^3$P$_0$ transition in $^{87}$Sr is 429,228,004,229,873.13(17) Hz. Our result is in excellent agreement with recent measurements performed in different laboratories worldwide. We improved the total systematic uncertainty of our Sr frequency standard by a factor of five and reach $3\times 10^{-17}$, opening new prospects for frequency ratio measurements between optical clocks for fundamental research, geodesy, or optical clock evaluation.

preprint2011arXiv

Demonstration of a Transportable 1 Hz-Linewidth Laser

We present the setup and test of a transportable clock laser at 698 nm for a strontium lattice clock. A master-slave diode laser system is stabilized to a rigidly mounted optical reference cavity. The setup was transported by truck over 400 km from Braunschweig to Düsseldorf, where the cavity-stabilized laser was compared to a stationary clock laser for the interrogation of ytterbium (578 nm). Only minor realignments were necessary after the transport. The lasers were compared by a Ti:Sapphire frequency comb used as a transfer oscillator. The thus generated virtual beat showed a combined linewidth below 1 Hz (at 1156 nm). The transport back to Braunschweig did not degrade the laser performance, as was shown by interrogating the strontium clock transition.

preprint2010arXiv

Mapping cellular magnesium using X-ray microfluorescence and atomic force microscopy

Magnesium is the most abundant intracellular divalent cation. We present an innovative experimental approach to localizing intracellular magnesium that combines elemental and morphological information from individual cells with high-resolution spatial information. Integration of information from scanning fluorescence X-ray microscopy with information from atomic force microscopy was used to generate a magnesium concentration map and to determine the X-ray linear absorption coefficient map within a whole dehydrated mammary epithelial cell.