Source author record

Christian Grebing

Christian Grebing appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

9works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2022arXiv

Gas-plasma based generation of broadband THz radiation with 640 mW average power

We present a high-power source of broadband terahertz radiation covering the whole THz spectral region (0.1-30 THz). The two-color gas plasma generation process is driven by a state-of-the-art Ytterbium fiber chirped pulse amplification system based on coherent combination of 16 rod-type amplifiers. Prior to the THz generation, the pulses are spectrally broadened in a multi-pass-cell and compressed to 37 fs with a pulse-energy of 1.3 mJ at a repetition rate of 500 kHz. A gas-jet scheme has been employed for the THz generation, increasing the efficiency of the process to 0.1%. The air-biased-coherent-detection scheme is implemented to characterize the full bandwidth of the generated radiation. A THz average power of 640 mW is generated, which is the highest THz average power achieved to date. This makes this source suitable for a variety of applications, e.g. spectroscopy of strongly absorbing samples or driving nonlinear effects for the studies of material properties.

preprint2022arXiv

Multipass cell for high-power few-cycle compression

A multipass cell for nonlinear compression to few-cycle pulse duration is introduced comprising dielectrically enhanced silver mirrors on silicon substrates. Spectral broadening with 388 W output average power and 776 μJ pulse energy is obtained at 82% cell transmission. A high output beam quality (M2<1.2) and a high spatio-spectral homogeneity (97.5%) as well as the compressibility of the output pulses to 6.9 fs duration are demonstrated. Finite element analysis reveals scalability of this cell to 2 kW average output power.

preprint2022arXiv

The scaling potential of beam-splitter-based coherent beam combination

The impact of nonlinear refraction and residual absorption on the achievable peak and average power in beam-splitter-based coherent beam combination is analyzed theoretically. While the peak power remains limited only by the aperture size, a fundamental average power limit is given by the thermo-optical and thermo-mechanical properties of the beam splitter material and its coatings. Based on our analysis, 100 kW average power can be obtained with state-of-the-art optics at maintained high beam quality (M2 {\leq} 1.1) and at only 2% loss of combining efficiency. This result indicates that the power-scaling potential of today's beam-splitter-based coherent beam combination is far from being depleted. A potential scaling route to megawatt-level average power is discussed for optimized beam splitter geometry.

preprint2021arXiv

Kilowatt-average-power compression of millijoule pulses in a gas-filled multi-pass cell

We demonstrate the reliable generation of 1-mJ, 31-fs pulses with an average power of 1 kW by post-compression of 200-fs pulses from a coherently combined Yb:fiber laser system in an argon-filled Herriott-type multi-pass cell with an overall compression efficiency of 96%. We also analyze the output beam, revealing essentially no spatio-spectral couplings or beam quality loss.

preprint2016arXiv

A tunable low-drift laser stabilized to an atomic reference

We present a laser system with a linewidth and long-term frequency stability at the 50 kHz level. It is based on a Ti:Sapphire laser emitting radiation at 882 nm which is referenced to an atomic transition. For this, the length of an evacuated transfer cavity is stabilized to a reference laser at 780 nm locked to the $^{85}$Rb D$_2$-line via modulation transfer spectroscopy. Gapless frequency tuning of the spectroscopy laser is realized using the sideband locking technique to the transfer cavity. In this configuration, the linewidth of the spectroscopy laser is derived from the transfer cavity, while the long-term stability is derived from the atomic resonance. Using an optical frequency comb, the frequency stability and linewidth of both lasers are characterized by comparison against an active hydrogen maser frequency standard and an ultra-narrow linewidth laser, respectively. The laser system presented here will be used for spectroscopy of the $1s^{2}2s^{2}2p\ ^{2}P_{1/2} -\ ^{2}P_{3/2}$ transition in sympathetically cooled Ar$^{13+}$ ions at 441nm after frequency doubling.

preprint2015arXiv

8E-17 fractional laser frequency instability with a long room-temperature cavity

We present a laser system based on a 48 cm long optical glass resonator. The large size requires a sophisticated thermal control and optimized mounting design. A self balancing mounting was essential to reliably reach sensitivities to acceleration of below $Δν/ ν$ < 2E-10 /g in all directions. Furthermore, fiber noise cancellations from a common reference point near the laser diode to the cavity mirror and to additional user points (Sr clock and frequency comb) are implemented. Through comparison to other cavity-stabilized lasers and to a strontium lattice clock an instability of below 1E-16 at averaging times from 1 s to 1000 s is revealed.

preprint2015arXiv

Characterization of a 450-km Baseline GPS Carrier-Phase Link using an Optical Fiber Link

A GPS carrier-phase frequency transfer link along a baseline of 450 km has been established and is characterized by comparing it to a phase-stabilized optical fiber link of 920 km length, established between the two endpoints, the Max-Planck-Institut für Quantenoptik in Garching and the Physikalisch-Technische Bundesanstalt in Braunschweig. The characterization is accomplished by comparing two active hydrogen masers operated at both institutes. The masers serve as local oscillators and cancel out when the double differences are calculated, such that they do not constitute a limitation for the GPS link characterization. We achieve a frequency instability of 3 x 10^(-13) in 30 s and 5 x 10^(-16) for long averaging times. Frequency comparison results obtained via both links show no deviation larger than the statistical uncertainty of 6 x 10^(-16). These results can be interpreted as a successful cross-check of the measurement uncertainty of a truly remote end fiber link.

preprint2014arXiv

A strontium lattice clock with $3 \times 10^{-17}$ inaccuracy and its frequency

We have measured the absolute frequency of the optical lattice clock based on $^{87}$Sr at PTB with an uncertainty of $3.9\times 10^{-16}$ using two caesium fountain clocks. This is close to the accuracy of today's best realizations of the SI second. The absolute frequency of the 5s$^2$ $^1$S$_0$-5s5p $^3$P$_0$ transition in $^{87}$Sr is 429,228,004,229,873.13(17) Hz. Our result is in excellent agreement with recent measurements performed in different laboratories worldwide. We improved the total systematic uncertainty of our Sr frequency standard by a factor of five and reach $3\times 10^{-17}$, opening new prospects for frequency ratio measurements between optical clocks for fundamental research, geodesy, or optical clock evaluation.

preprint2014arXiv

Ultra-stable laser with average fractional frequency drift rate below $5\times10^{-19}/\mathrm{s}$

Cryogenic single-crystal optical cavities have the potential to provide highest dimensional stability. We have investigated the long-term performance of an ultra-stable laser system which is stabilized to a single-crystal silicon cavity operated at 124 K. Utilizing a frequency comb, the laser is compared to a hydrogen maser that is referenced to a primary caesium fountain standard and to the $^{87}\mathrm{Sr}$ optical lattice clock at PTB. With fractional frequency instabilities of $σ_y(τ)\leq2\times10^{-16}$ for averaging times of $τ=60\mathrm{~s}$ to $1000\mathrm{~s}$ and $σ_y(1 \mathrm{d})\leq 2\times10^{-15}$ the stability of this laser, without any aid from an atomic reference, surpasses the best microwave standards for short averaging times and is competitive with the best hydrogen masers for longer times of one day. The comparison of modeled thermal response of the cavity with measured data indicates a fractional frequency drift below $5\times 10^{-19}/\mathrm{s}$, which we do not expect to be a fundamental limit.