Source author record

Sebastian Häfner

Sebastian Häfner appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2020arXiv

A transportable interrogation laser system with an instability of $\mathrm{mod}\,σ_{\rm y} = 3\times10^{-16}$

We present an interrogation laser system for a transportable strontium lattice clock operating at 698 nm, which is based on an ultra-low-expansion glass reference cavity. Transportability is achieved by implementing a rigid, compact, and vibration insensitive mounting of the 12 cm-long reference cavity, sustaining shocks of up to 50 g. The cavity is mounted at optimized support points that independently constrain all degrees of freedom. This mounting concept is especially beneficial for cavities with a ratio of length $L$ over diameter $D$ $L/D>1$. Generally large $L$ helps to reduce thermal noise-induced laser frequency instability while small $D$ leads to small cavity volume. The frequency instability was evaluated, reaching its thermal noise floor of $\mathrm{mod}\,σ_{\rm y} \approx 3 \times 10^{-16}$ for averaging times between 0.5 s and 10 s. The laser system was successfully operated during several field studies.

preprint2015arXiv

8E-17 fractional laser frequency instability with a long room-temperature cavity

We present a laser system based on a 48 cm long optical glass resonator. The large size requires a sophisticated thermal control and optimized mounting design. A self balancing mounting was essential to reliably reach sensitivities to acceleration of below $Δν/ ν$ < 2E-10 /g in all directions. Furthermore, fiber noise cancellations from a common reference point near the laser diode to the cavity mirror and to additional user points (Sr clock and frequency comb) are implemented. Through comparison to other cavity-stabilized lasers and to a strontium lattice clock an instability of below 1E-16 at averaging times from 1 s to 1000 s is revealed.

preprint2015arXiv

Noise and instability of an optical lattice clock

We present an analysis of the different types of noise from the detection and interrogation laser in our strontium lattice clock. We develop a noise model showing that in our setup quantum projection noise--limited detection is possible if more than 130~atoms are interrogated. Adding information about the noise spectrum of our clock laser with sub-$10^{-16}$ fractional frequency instability allows to infer the clock stability for different modes of operation. Excellent agreement with experimental observations for the instability of the difference between two interleaved stabilizations is found. We infer a clock instability of $1.6 \times 10^{-16}/\sqrt{τ/ \mathrm{s}}$ as a function of averaging time $τ$ for normal clock operation.

preprint2014arXiv

A compact, robust, and transportable ultra-stable laser with a fractional frequency instability of $1\times10^{-15}$

We present a compact and robust transportable ultra-stable laser system with minimum fractional frequency instability of $1\times10^{-15}$ at integration times between 1 to 10 s. The system was conceived as a prototype of a subsystem of a microwave-optical local oscillator to be used on the satellite mission STE-QUEST (Space-Time Explorer and QUantum Equivalence Principle Space Test, http://sci.esa.int/ste-quest/). It was therefore designed to be compact, to sustain accelerations occurring during rocket launch, to exhibit low vibration sensitivity, and to reach a low frequency instability. Overall dimensions of the optical system are $40\textrm{ cm}\times20\textrm{ cm}\times30\textrm{ cm}$. The acceleration sensitivities of the optical frequency in the three directions were measured to be $1.7\times10^{-11}/g$, $8.0\times10^{-11}/g$, and $3.9\times10^{-10}/g$, and the absolute frequency instability was determined via a three-cornered hat measurement. The design is also appropriate and useful for terrestrial applications.

preprint2014arXiv

A strontium lattice clock with $3 \times 10^{-17}$ inaccuracy and its frequency

We have measured the absolute frequency of the optical lattice clock based on $^{87}$Sr at PTB with an uncertainty of $3.9\times 10^{-16}$ using two caesium fountain clocks. This is close to the accuracy of today's best realizations of the SI second. The absolute frequency of the 5s$^2$ $^1$S$_0$-5s5p $^3$P$_0$ transition in $^{87}$Sr is 429,228,004,229,873.13(17) Hz. Our result is in excellent agreement with recent measurements performed in different laboratories worldwide. We improved the total systematic uncertainty of our Sr frequency standard by a factor of five and reach $3\times 10^{-17}$, opening new prospects for frequency ratio measurements between optical clocks for fundamental research, geodesy, or optical clock evaluation.