Source author record

Uwe Sterr

Uwe Sterr appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

23works
8topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

23 published item(s)

preprint2020arXiv

A transportable interrogation laser system with an instability of $\mathrm{mod}\,σ_{\rm y} = 3\times10^{-16}$

We present an interrogation laser system for a transportable strontium lattice clock operating at 698 nm, which is based on an ultra-low-expansion glass reference cavity. Transportability is achieved by implementing a rigid, compact, and vibration insensitive mounting of the 12 cm-long reference cavity, sustaining shocks of up to 50 g. The cavity is mounted at optimized support points that independently constrain all degrees of freedom. This mounting concept is especially beneficial for cavities with a ratio of length $L$ over diameter $D$ $L/D>1$. Generally large $L$ helps to reduce thermal noise-induced laser frequency instability while small $D$ leads to small cavity volume. The frequency instability was evaluated, reaching its thermal noise floor of $\mathrm{mod}\,σ_{\rm y} \approx 3 \times 10^{-16}$ for averaging times between 0.5 s and 10 s. The laser system was successfully operated during several field studies.

preprint2020arXiv

End-to-end topology for fiber comb based optical frequency transfer at the $10^{-21}$ level

We introduce a simple and robust scheme for optical frequency transfer of an ultra-stable source light field via an optical frequency comb to a field at a target optical frequency, where highest stability is required, e.g. for the interrogation of an optical clock. The scheme relies on a topology for end-to-end suppression of the influence of optical path-length fluctuations, which is attained by actively phase-stabilized delivery, combined with common-path propagation. This approach provides a robust stability improvement without the need for additional isolation against environmental disturbances such as temperature, pressure or humidity changes. We measure residual frequency transfer instabilities by comparing the frequency transfers carried out with two independent combs simultaneously. Residual fractional frequency instabilities between two systems of $8\times10^{-18}$ at 1 s and $3\times10^{-21}$ at $10^5$ s averaging time are observed. We discuss the individual noise contributions to the residual instability. The presented scheme is technically simple, robust against environmental parameter fluctuations, and enables an ultra-stable frequency transfer, e.g. to optical clock lasers or to lasers in gravitational wave detectors.

preprint2020arXiv

Optical frequency ratio of a ${}^{171}\mathrm{Yb}^+$ single-ion clock and a ${}^{87}\mathrm{Sr}$ lattice clock

We report direct measurements of the frequency ratio of the 642 THz ${}^2S_{1/2} (F=0)$--${}^2F_{7/2} (F=3)$ electric octupole transition in ${}^{171}\mathrm{Yb}^+$ and the 429 THz ${}^1S_0$--${}^3P_0$ transition in ${}^{87}\mathrm{Sr}$. A series of 107 measurements has been performed at the Physikalisch-Technische Bundesanstalt between December 2012 and October 2019. Long-term variations of the ratio are larger than expected from the individual measurement uncertainties of few $10^{-17}$. The cause of these variations remains unknown. Even taking these into account, we find a fractional uncertainty of the frequency ratio of $2.5 \times 10^{-17}$, which improves upon previous knowledge by one order of magnitude. The average frequency ratio is $ν_{\mathrm{Yb}^+} / ν_{\mathrm{Sr}} = 1.495\,991\,618\,544\,900\,537(38)$. This represents one of the most accurate measurements between two different atomic species to date.

preprint2020arXiv

Thermal noise and mechanical loss of SiO$_2$/Ta$_2$O$_5$ optical coatings at cryogenic temperatures

Mechanical loss of dielectric mirror coatings sets fundamental limits for both gravitational wave detectors and cavity-stabilized optical local oscillators for atomic clocks. Two approaches are used to determine the mechanical loss: ringdown measurements of the coating quality factor and direct measurement of the coating thermal noise. Here we report a systematic study of the mirror thermal noise from room temperature to 4 K by operating reference cavities at these temperatures. The directly measured thermal noise is used to extract the corresponding mechanical loss for SiO$_2$/Ta$_2$O$_5$ coatings, which are compared with previously reported values.

preprint2015arXiv

8E-17 fractional laser frequency instability with a long room-temperature cavity

We present a laser system based on a 48 cm long optical glass resonator. The large size requires a sophisticated thermal control and optimized mounting design. A self balancing mounting was essential to reliably reach sensitivities to acceleration of below $Δν/ ν$ < 2E-10 /g in all directions. Furthermore, fiber noise cancellations from a common reference point near the laser diode to the cavity mirror and to additional user points (Sr clock and frequency comb) are implemented. Through comparison to other cavity-stabilized lasers and to a strontium lattice clock an instability of below 1E-16 at averaging times from 1 s to 1000 s is revealed.

preprint2015arXiv

Noise and instability of an optical lattice clock

We present an analysis of the different types of noise from the detection and interrogation laser in our strontium lattice clock. We develop a noise model showing that in our setup quantum projection noise--limited detection is possible if more than 130~atoms are interrogated. Adding information about the noise spectrum of our clock laser with sub-$10^{-16}$ fractional frequency instability allows to infer the clock stability for different modes of operation. Excellent agreement with experimental observations for the instability of the difference between two interleaved stabilizations is found. We infer a clock instability of $1.6 \times 10^{-16}/\sqrt{τ/ \mathrm{s}}$ as a function of averaging time $τ$ for normal clock operation.

preprint2015arXiv

Nonlinear Zeeman effect in photoassociation spectra of $^{40}$Ca near the $^3$P$_1$+$^1$S$_0$ asymptote

We present calculations of the Zeeman effect of narrow photoassociation lines of $^{40}$Ca near the $^3$P$_1$ + $^1$S$_0$ asymptote. Using a coupled-channel model we find a nonlinear Zeeman effect that even at low fields of a few mT amounts to several kHz. With this model we analyze previous measurements and give corrected long range dispersion coefficients of the $^3Π_{u}$ and $^3Σ^+ _{u}$ states.

preprint2015arXiv

On the relation between uncertainties of weighted frequency averages and the various types of Allan deviations

The power spectral density in Fourier frequency domain, and the different variants of the Allan deviation (ADEV) in dependence on the averaging time are well established tools to analyse the fluctuation properties and frequency instability of an oscillatory signal. It is often supposed that the statistical uncertainty of a measured average frequency is given by the ADEV at a well considered averaging time. However, this approach requires further mathematical justification and refinement, which has already been done regarding the original ADEV for certain noise types. Here we provide the necessary background to use the modified Allan deviation (modADEV) and other two-sample deviations to determine the uncertainty of weighted frequency averages. The type of two-sample deviation used to determine the uncertainty depends on the method used for determination of the average. We find that the modADEV, which is connected with $Λ$-weighted averaging, and the two sample deviation associated to a linear phase regression weighting (parADEV) are in particular advantageous for measurements, in which white phase noise is dominating. Furthermore, we derive a procedure how to minimize the uncertainty of a measurement for a typical combination of white phase and frequency noise by adaptive averaging of the data set with different weighting functions. Finally, some aspects of the theoretical considerations for real-world frequency measurement equipment are discussed.

preprint2014arXiv

A compact, robust, and transportable ultra-stable laser with a fractional frequency instability of $1\times10^{-15}$

We present a compact and robust transportable ultra-stable laser system with minimum fractional frequency instability of $1\times10^{-15}$ at integration times between 1 to 10 s. The system was conceived as a prototype of a subsystem of a microwave-optical local oscillator to be used on the satellite mission STE-QUEST (Space-Time Explorer and QUantum Equivalence Principle Space Test, http://sci.esa.int/ste-quest/). It was therefore designed to be compact, to sustain accelerations occurring during rocket launch, to exhibit low vibration sensitivity, and to reach a low frequency instability. Overall dimensions of the optical system are $40\textrm{ cm}\times20\textrm{ cm}\times30\textrm{ cm}$. The acceleration sensitivities of the optical frequency in the three directions were measured to be $1.7\times10^{-11}/g$, $8.0\times10^{-11}/g$, and $3.9\times10^{-10}/g$, and the absolute frequency instability was determined via a three-cornered hat measurement. The design is also appropriate and useful for terrestrial applications.

preprint2014arXiv

A strontium lattice clock with $3 \times 10^{-17}$ inaccuracy and its frequency

We have measured the absolute frequency of the optical lattice clock based on $^{87}$Sr at PTB with an uncertainty of $3.9\times 10^{-16}$ using two caesium fountain clocks. This is close to the accuracy of today's best realizations of the SI second. The absolute frequency of the 5s$^2$ $^1$S$_0$-5s5p $^3$P$_0$ transition in $^{87}$Sr is 429,228,004,229,873.13(17) Hz. Our result is in excellent agreement with recent measurements performed in different laboratories worldwide. We improved the total systematic uncertainty of our Sr frequency standard by a factor of five and reach $3\times 10^{-17}$, opening new prospects for frequency ratio measurements between optical clocks for fundamental research, geodesy, or optical clock evaluation.

preprint2014arXiv

Quantum Tests of the Einstein Equivalence Principle with the STE-QUEST Space Mission

We present in detail the scientific objectives in fundamental physics of the Space-Time Explorer and QUantum Equivalence Space Test (STE-QUEST) space mission. STE-QUEST was pre-selected by the European Space Agency together with four other missions for the cosmic vision M3 launch opportunity planned around 2024. It carries out tests of different aspects of the Einstein Equivalence Principle using atomic clocks, matter wave interferometry and long distance time/frequency links, providing fascinating science at the interface between quantum mechanics and gravitation that cannot be achieved, at that level of precision, in ground experiments. We especially emphasize the specific strong interest of performing equivalence principle tests in the quantum regime, i.e. using quantum atomic wave interferometry. Although STE-QUEST was finally not selected in early 2014 because of budgetary and technological reasons, its science case was very highly rated. Our aim is to expose that science to a large audience in order to allow future projects and proposals to take advantage of the STE-QUEST experience.

preprint2014arXiv

Ultra-stable laser with average fractional frequency drift rate below $5\times10^{-19}/\mathrm{s}$

Cryogenic single-crystal optical cavities have the potential to provide highest dimensional stability. We have investigated the long-term performance of an ultra-stable laser system which is stabilized to a single-crystal silicon cavity operated at 124 K. Utilizing a frequency comb, the laser is compared to a hydrogen maser that is referenced to a primary caesium fountain standard and to the $^{87}\mathrm{Sr}$ optical lattice clock at PTB. With fractional frequency instabilities of $σ_y(τ)\leq2\times10^{-16}$ for averaging times of $τ=60\mathrm{~s}$ to $1000\mathrm{~s}$ and $σ_y(1 \mathrm{d})\leq 2\times10^{-15}$ the stability of this laser, without any aid from an atomic reference, surpasses the best microwave standards for short averaging times and is competitive with the best hydrogen masers for longer times of one day. The comparison of modeled thermal response of the cavity with measured data indicates a fractional frequency drift below $5\times 10^{-19}/\mathrm{s}$, which we do not expect to be a fundamental limit.

preprint2013arXiv

High accuracy photoassociation of $^{40}$Ca near the ${^3P_1}+{^1S_0}$ asymptote and its Zeeman effect

We report on the first measurement of narrow photoassociation lines of $^{40}$Ca near the ${^3P_1}+{^1S_0}$ asymptote related to the molecular states $^3Π_u$ and $^3Σ^+_u$. The highly accurate binding energies and Zeeman splittings are well described by a coupled channel theoretical model, confirming theoretical predictions of long-range coefficients. Our analysis shows that only the inclusion of both energies and Zeeman splittings provides an accurate description of the long-range interaction potentials.

preprint2013arXiv

Reducing the effect of thermal noise in optical cavities

Thermal noise in optical cavities imposes a severe limitation in the stability of the most advanced frequency standards at a level of a few 10^(-16) (s/t)^(1/2) for long averaging times t. In this paper we describe two schemes for reducing the effect of thermal noise in a reference cavity. In the first approach, we investigate the potential and limitations of operating the cavity close to instability, where the beam diameter on the mirrors becomes large. Our analysis shows that even a 10 cm short cavity can achieve a thermal noise limited fractional frequency instability in the low 10^(-16) regime. In the second approach, we increase the length of the optical cavity. We show that a 39.5 cm long cavity has the potential for a fractional frequency instability even below 10^(-16), while it seems feasible to achieve a reduced sensitivity of <10^(-10)/g for vibration-induced fractional length changes in all three directions.

preprint2012arXiv

A compact and efficient strontium oven for laser-cooling experiments

Here we describe a compact and efficient strontium oven well suited for laser-cooling experiments. Novel design solutions allowed us to produce a collimated strontium atomic beam with a flux of 1.0\times10^13 s^-1 cm^-2 at the oven temperature of 450 °C, reached with an electrical power consumption of 36 W. The oven is based on a stainless-steel reservoir, filled with 6 g of metallic strontium, electrically heated in a vacuum environment by a tantalum wire threaded through an alumina multi-bore tube. The oven can be hosted in a standard DN40CF cube and has an estimated continuous operation lifetime of 10 years. This oven can be used for other alkali and alkaline earth metals with essentially no modifications.

preprint2012arXiv

Delivering pulsed and phase stable light to atoms of an optical clock

In optical clocks, transitions of ions or neutral atoms are interrogated using pulsed ultra-narrow laser fields. Systematic phase chirps of the laser or changes of the optical path length during the measurement cause a shift of the frequency seen by the interrogated atoms. While the stabilization of cw-optical links is now a well established technique even on long distances, phase stable links for pulsed light pose additional challanges and have not been demonstrated so far. In addition to possible temperature or pressure drift of the laboratory, which may lead to a Doppler shift by steadily changing the optical path length, the pulsing of the clock laser light calls for short settling times of stabilization locks. Our optical path length stabilization uses retro-reflected light from a mirror that is fixed with respect to the interrogated atoms and synthetic signals during the dark time. Length changes and frequency chirps are compensated for by the switching AOM. For our strontium optical lattice clock we have ensured that the shift introduced by the fiber link including the pulsing acousto optic modulator is below $2\cdot 10^{-17}$.

preprint2012arXiv

High accuracy correction of blackbody radiation shift in an optical lattice clock

We have determined the frequency shift that blackbody radiation is inducing on the $5s^2$ $^1$S$_0$ -- $5s5p$ $^3$P$_0$ clock transition in strontium. Previously its uncertainty limited the uncertainty of strontium lattice clocks to $1\times10^{-16}$. Now the uncertainty associated to the black body radiation shift correction translates to $5\times 10^{-18}$ relative frequency uncertainty at room temperature. Our evaluation is based on a measurement of the differential dc-polarizability of the two clock states and on a modeling of the dynamic contribution using this value and experimental data for other atomic properties.

preprint2012arXiv

Long range transport of ultra cold atoms in a far-detuned 1D optical lattice

We present a novel method to transport ultra cold atoms in a focused optical lattice over macroscopic distances of many Rayleigh ranges. With this method ultra cold atoms were transported over 5 cm in 250 ms without significant atom loss or heating. By translating the interference pattern together with the beam geometry the trap parameters are maintained over the full transport range. Thus, the presented method is well suited for tightly focused optical lattices that have sufficient trap depth only close to the focus. Tight focusing is usually required for far-detuned optical traps or traps that require high laser intensity for other reasons. The transport time is short and thus compatible with the operation of an optical lattice clock in which atoms are probed in a well designed environment spatially separated from the preparation and detection region.

preprint2011arXiv

Demonstration of a Transportable 1 Hz-Linewidth Laser

We present the setup and test of a transportable clock laser at 698 nm for a strontium lattice clock. A master-slave diode laser system is stabilized to a rigidly mounted optical reference cavity. The setup was transported by truck over 400 km from Braunschweig to Düsseldorf, where the cavity-stabilized laser was compared to a stationary clock laser for the interrogation of ytterbium (578 nm). Only minor realignments were necessary after the transport. The lasers were compared by a Ti:Sapphire frequency comb used as a transfer oscillator. The thus generated virtual beat showed a combined linewidth below 1 Hz (at 1156 nm). The transport back to Braunschweig did not degrade the laser performance, as was shown by interrogating the strontium clock transition.

preprint2011arXiv

Thermal noise in optical cavities revisited

Thermal noise of optical reference cavities sets a fundamental limit to the frequency instability of ultra-stable lasers. Using Levin's formulation of the fluctuation-dissipation theorem we correct the analytical estimate for the spacer contribution given by Numata et al.. For detailed analysis finite-element calculations of the thermal noise focusing on the spacer geometry, support structure and the usage of different materials have been carried out. We find that the increased dissipation close to the contact area between spacer and mirrors can contribute significantly to the thermal noise. From an estimate of the support structure contribution we give guidelines for a low-noise mounting of the cavity. For mixed-material cavities we show that the thermal expansion can be compensated without deteriorating the thermal noise.

preprint2010arXiv

Tackling the blackbody shift in a strontium optical lattice clock

A major obstacle for optical clocks is the frequency shift due to black body radiation. We discuss how one can tackle this problem in an optical lattice clock; in our case 87-Sr: firstly, by a measurement of the dc Stark shift of the clock transition and, secondly, by interrogating the atoms in a cryogenic environment. Both approaches rely on transporting ultracold atoms over several cm within a probe cycle. We evaluate this approach of mechanically moving the optical lattice and conclude that it is feasible to transport the atoms over 50 mm within 300 ms. With this transport a dc Stark shift measurement will allow to reduce the contribution of the blackbody radiation to the fractional uncertainty below 2 * 10^-17 at room temperature by improving the shift coefficient known only from atomic structure calculations up to now. We propose a cryogenic environment at 77 K that will reduce this contribution to few parts in 10^-18.

preprint2010arXiv

Tuning the Thermal Expansion Properties of Optical Reference Cavities with Fused Silica Mirrors

We investigate the thermal expansion of low thermal noise Fabry-Perot cavities made of Low Thermal Expansion (LTE) glass spacers and Fused Silica (FS) mirrors. The different thermal expansion of mirror and spacer deforms the mirror. This deformation strongly contributes to the cavity's effective Coefficient of Thermal Expansion (CTE), decreasing the zero crossing temperature by about 20 K compared to an all-LTE glass cavity. Finite element simulations and CTE measurements show that LTE rings optically contacted to the back surface of the FS mirrors allow to tune the zero crossing temperature over a range of 30 K.

preprint2009arXiv

Phase- coherent comparison of two optical frequency standards over 146 km using a telecommunication fiber link

We have explored the performance of two "dark fibers" of a commercial telecommunication fiber link for a remote comparison of optical clocks. The two fibers, linking the Leibniz University of Hanover (LUH) with the Physi-kalisch-Technische Bundesanstalt (PTB) in Braunschweig, are connected in Hanover to form a total fiber length of 146 km. At PTB the performance of an optical frequency standard operating at 456 THz was imprinted to a cw trans-fer laser at 194 THz, and its frequency was transmitted over the fiber. In order to detect and compensate phase noise related to the optical fiber link we have built a low-noise optical fiber interferometer and investigated noise sources that affect the overall performance of the optical link. The frequency stability at the remote end has been measured using the clock laser of PTB's Yb+ frequency standard operating at 344 THz. We show that the frequency of a frequency-stabilized fiber laser can be transmitted over a total fiber length of 146 km with a relative frequency uncertainty below 1E-19, and short term frequency instability given by the fractional Allan deviation of sy(t)=3.3E-15/(t/s).