Source author record

Adam J. Fleisher

Adam J. Fleisher appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

7works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2026arXiv

Bridging Theory and Experiment in Virtually Imaged Phased Array (VIPA) Spectrometers

Virtually imaged phased array (VIPA) spectrometers provide high resolution and fast acquisition in a compact design, but their performance as dispersive instruments is sensitive to fabrication tolerances, component dimensions, and alignment. Here, leveraging numerical simulations validated by experimental data, we present a framework to identify the parameters that limit VIPA spectrometer resolution. This framework is applied to the construction of a new mid infrared VIPA spectrometer, tested at wavelengths near 4.6 um with both continuous-wave and frequency-comb laser sources, with a resolving power predicted by analytical expressions to be as high as RP = 830 000 (corresponding to a resolution of 78 MHz). Validated numerical simulations, however, provided a more realistic estimate that captures limits set by all the optical components. By correcting aberrations and optimizing alignment, a resolving power of RP = 440 000 (150 MHz) was experimentally achieved, corresponding to 80% of the value predicted by numerical simulation of the entire spectrometer. These results bridge the gap between analytical design expressions and experimental results for compact, high-resolution VIPA spectrometers to enable more efficient fabrication and advanced design across critical areas like applied space optics, line-by-line pulse shaping, and broadband spectral sensors.

preprint2020arXiv

Cavity ring-down spectroscopy of CO$_2$ near $λ$ = 2.06 $μ$m: Accurate transition intensities for the Orbiting Carbon Observatory-2 (OCO-2) "strong band"

The $λ$ = 2.06 $μ$m absorption band of CO$_2$ is widely used for the remote sensing of atmospheric carbon dioxide, making it relevant to many important top-down measurements of carbon flux. The forward models used in the retrieval algorithms employed in these measurements require increasingly accurate line intensity and line shape data from which absorption cross-sections can be computed. To overcome accuracy limitations of existing line lists, we used frequency-stabilized cavity ring-down spectroscopy to measure 39 transitions in the $^{12}$C$^{16}$O$_2$ absorption band. The line intensities were measured with an estimated relative combined standard uncertainty of $u_r$ = 0.08 %. We predict the $J$-dependence of the measured intensities using two theoretical modesl: a one-dimensional spectroscopic model with Herman-Wallis rotation-vibration corrections, and a line-by-line ab initio dipole moment surface model [Zak et al. JQSRT 2016;177:31-42]. For the second approach, we fit only a single factor to rescale the theoretical integrated band intensity to be consistent with the measured intensities. We find that the latter approach yields an equally adequate representation of the fitted $J$-dependent intensity data and provides the most physically general representation of the results. Our recommended value for the integrated band intensity equal to 7.183$\times$10$^{-21}$ cm molecule$^{-1}$ $\pm$ 6$\times$10$^{-24}$ cm molecule$^{-1}$ is based on the rescaled ab initio model and corresponds to a fitted scale factor of 1.0069 $\pm$ 0.0002. Comparisons of literature intensity values to our results reveal systematic deviations ranging from $-$1.16 % to +0.33 %.

preprint2020arXiv

Doppler-Free Two-Photon Cavity Ring-Down Spectroscopy of a Nitrous Oxide (N$_2$O) Vibrational Overtone Transition

We report Doppler-free two-photon absorption of N$_2$O at $λ$ = 4.53 $μ$m, measured by cavity ring-down spectroscopy. High power was achieved by optical self-locking of a quantum cascade laser to a linear resonator of finesse $F$ = 22730, and accurate laser detuning over a 400 MHz range was measured relative to an optical frequency comb. At a sample pressure of p = 0.13 kPa, we report a large two-photon cross-section of $σ_{13}^{(2)}$ = 8.0 $\times$ 10$^{-41}$ cm$^4$ s molecule$^{-1}$ for the $Q$(18) rovibrational transition at a resonant frequency of $ν_0$ = 66179400.8 MHz.

preprint2016arXiv

Coherent cavity-enhanced dual-comb spectroscopy

Dual-comb spectroscopy allows for the rapid, multiplexed acquisition of high-resolution spectra without the need for moving parts or low-resolution dispersive optics. This method of broadband spectroscopy is most often accomplished via tight phase locking of two mode-locked lasers or via sophisticated signal processing algorithms, and therefore, long integration times of phase coherent signals are difficult to achieve. Here we demonstrate an alternative approach to dual-comb spectroscopy using two phase modulator combs originating from a single continuous-wave laser capable of > 2 hours of coherent real-time averaging. The dual combs were generated by driving the phase modulators with step-recovery diodes where each comb consisted of > 250 teeth with 203 MHz spacing and spanned > 50 GHz region in the near-infrared. The step-recovery diodes are passive devices that provide low-phase-noise harmonics for efficient coupling into an enhancement cavity at picowatt optical powers. With this approach, we demonstrate the sensitivity to simultaneously monitor ambient levels of CO2, CO, HDO, and H2O in a single spectral region at a maximum acquisition rate of 150 kHz. Robust, compact, low-cost and widely tunable dual-comb systems could enable a network of distributed multiplexed optical sensors.

preprint2016arXiv

Multiplexed sub-Doppler spectroscopy with an optical frequency comb

An optical frequency comb generated with an electro-optic phase modulator and a chirped radiofrequency waveform is used to perform saturation and pump-probe spectroscopy on the $D_1$ and $D_2$ transitions of atomic potassium. With a comb tooth spacing of 200 kHz and an optical bandwidth of 2 GHz the hyperfine transitions can be simultaneously observed. Interferograms are recorded in as little as 5 $μ$s (a timescale corresponding to the inverse of the comb tooth spacing). Importantly, the sub-Doppler features can be measured as long as the laser carrier frequency lies within the Doppler profile, thus removing the need for slow scanning or a priori knowledge of the frequencies of the sub-Doppler features. Sub-Doppler optical frequency comb spectroscopy has the potential to dramatically reduce acquisition times and allow for rapid and accurate assignment of complex molecular and atomic spectra which are presently intractable.

preprint2012arXiv

Cavity-enhanced optical frequency comb spectroscopy in the mid-infrared - application to trace detection of H2O2

We demonstrate the first cavity-enhanced optical frequency comb spectroscopy in the mid-infrared wavelength region and report the sensitive real-time trace detection of hydrogen peroxide in the presence of a large amount of water. The experimental apparatus is based on a mid-infrared optical parametric oscillator synchronously pumped by a high power Yb:fiber laser, a high finesse broadband cavity, and a fast-scanning Fourier transform spectrometer with autobalancing detection. The comb spectrum with a bandwidth of 200 nm centered around 3.75 μm is simultaneously coupled to the cavity and both degrees of freedom of the comb, i.e., the repetition rate and carrier envelope offset frequency, are locked to the cavity to ensure stable transmission. The autobalancing detection scheme reduces the intensity noise by a factor of 300, and a sensitivity of 5.4 {\times} 10^-9 cm^-1 Hz^-1/2 with a resolution of 800 MHz is achieved (corresponding to 6.9 {\times} 10^-11 cm^-1 Hz^-1/2 per spectral element for 6000 resolved elements). This yields a noise equivalent detection limit for hydrogen peroxide of 8 parts-per-billion (ppb); in the presence of 2.8% of water the detection limit is 130 ppb. Spectra of acetylene, methane and nitrous oxide at atmospheric pressure are also presented, and a line shape model is developed to simulate the experimental data.

preprint2012arXiv

Mid-infrared VIPA Spectrometer for Rapid and Broadband Trace Gas Detection

We present and characterize a 2-D imaging spectrometer based on a virtually-imaged phased array (VIPA) disperser for rapid, high-resolution molecular detection using mid-infrared (MIR) frequency combs at 3.1 and 3.8 μm. We demonstrate detection of CH4 at 3.1 μm with >3750 resolution elements spanning >80 nm with ~600 MHz resolution in a <10 μs acquisition time. In addition to broadband detection, rapid, time-resolved single-image detection is demonstrated by capturing dynamic concentration changes of CH4 at a rate of ~375 frames per second. Changes in absorption above the noise floor of 5\times 10-4 are readily detected on the millisecond time scale, leading to important future applications such as real time monitoring of trace gas concentrations and detection of reactive intermediates.