Source author record

Bryce Bjork

Bryce Bjork appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2012arXiv

Cavity-enhanced optical frequency comb spectroscopy in the mid-infrared - application to trace detection of H2O2

We demonstrate the first cavity-enhanced optical frequency comb spectroscopy in the mid-infrared wavelength region and report the sensitive real-time trace detection of hydrogen peroxide in the presence of a large amount of water. The experimental apparatus is based on a mid-infrared optical parametric oscillator synchronously pumped by a high power Yb:fiber laser, a high finesse broadband cavity, and a fast-scanning Fourier transform spectrometer with autobalancing detection. The comb spectrum with a bandwidth of 200 nm centered around 3.75 μm is simultaneously coupled to the cavity and both degrees of freedom of the comb, i.e., the repetition rate and carrier envelope offset frequency, are locked to the cavity to ensure stable transmission. The autobalancing detection scheme reduces the intensity noise by a factor of 300, and a sensitivity of 5.4 {\times} 10^-9 cm^-1 Hz^-1/2 with a resolution of 800 MHz is achieved (corresponding to 6.9 {\times} 10^-11 cm^-1 Hz^-1/2 per spectral element for 6000 resolved elements). This yields a noise equivalent detection limit for hydrogen peroxide of 8 parts-per-billion (ppb); in the presence of 2.8% of water the detection limit is 130 ppb. Spectra of acetylene, methane and nitrous oxide at atmospheric pressure are also presented, and a line shape model is developed to simulate the experimental data.

preprint2012arXiv

Mid-infrared VIPA Spectrometer for Rapid and Broadband Trace Gas Detection

We present and characterize a 2-D imaging spectrometer based on a virtually-imaged phased array (VIPA) disperser for rapid, high-resolution molecular detection using mid-infrared (MIR) frequency combs at 3.1 and 3.8 μm. We demonstrate detection of CH4 at 3.1 μm with >3750 resolution elements spanning >80 nm with ~600 MHz resolution in a <10 μs acquisition time. In addition to broadband detection, rapid, time-resolved single-image detection is demonstrated by capturing dynamic concentration changes of CH4 at a rate of ~375 frames per second. Changes in absorption above the noise floor of 5\times 10-4 are readily detected on the millisecond time scale, leading to important future applications such as real time monitoring of trace gas concentrations and detection of reactive intermediates.