Source author record

Joseph T. Hodges

Joseph T. Hodges appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2020arXiv

Cavity ring-down spectroscopy of CO$_2$ near $λ$ = 2.06 $μ$m: Accurate transition intensities for the Orbiting Carbon Observatory-2 (OCO-2) "strong band"

The $λ$ = 2.06 $μ$m absorption band of CO$_2$ is widely used for the remote sensing of atmospheric carbon dioxide, making it relevant to many important top-down measurements of carbon flux. The forward models used in the retrieval algorithms employed in these measurements require increasingly accurate line intensity and line shape data from which absorption cross-sections can be computed. To overcome accuracy limitations of existing line lists, we used frequency-stabilized cavity ring-down spectroscopy to measure 39 transitions in the $^{12}$C$^{16}$O$_2$ absorption band. The line intensities were measured with an estimated relative combined standard uncertainty of $u_r$ = 0.08 %. We predict the $J$-dependence of the measured intensities using two theoretical modesl: a one-dimensional spectroscopic model with Herman-Wallis rotation-vibration corrections, and a line-by-line ab initio dipole moment surface model [Zak et al. JQSRT 2016;177:31-42]. For the second approach, we fit only a single factor to rescale the theoretical integrated band intensity to be consistent with the measured intensities. We find that the latter approach yields an equally adequate representation of the fitted $J$-dependent intensity data and provides the most physically general representation of the results. Our recommended value for the integrated band intensity equal to 7.183$\times$10$^{-21}$ cm molecule$^{-1}$ $\pm$ 6$\times$10$^{-24}$ cm molecule$^{-1}$ is based on the rescaled ab initio model and corresponds to a fitted scale factor of 1.0069 $\pm$ 0.0002. Comparisons of literature intensity values to our results reveal systematic deviations ranging from $-$1.16 % to +0.33 %.

preprint2020arXiv

Doppler-Free Two-Photon Cavity Ring-Down Spectroscopy of a Nitrous Oxide (N$_2$O) Vibrational Overtone Transition

We report Doppler-free two-photon absorption of N$_2$O at $λ$ = 4.53 $μ$m, measured by cavity ring-down spectroscopy. High power was achieved by optical self-locking of a quantum cascade laser to a linear resonator of finesse $F$ = 22730, and accurate laser detuning over a 400 MHz range was measured relative to an optical frequency comb. At a sample pressure of p = 0.13 kPa, we report a large two-photon cross-section of $σ_{13}^{(2)}$ = 8.0 $\times$ 10$^{-41}$ cm$^4$ s molecule$^{-1}$ for the $Q$(18) rovibrational transition at a resonant frequency of $ν_0$ = 66179400.8 MHz.

preprint2016arXiv

Coherent cavity-enhanced dual-comb spectroscopy

Dual-comb spectroscopy allows for the rapid, multiplexed acquisition of high-resolution spectra without the need for moving parts or low-resolution dispersive optics. This method of broadband spectroscopy is most often accomplished via tight phase locking of two mode-locked lasers or via sophisticated signal processing algorithms, and therefore, long integration times of phase coherent signals are difficult to achieve. Here we demonstrate an alternative approach to dual-comb spectroscopy using two phase modulator combs originating from a single continuous-wave laser capable of > 2 hours of coherent real-time averaging. The dual combs were generated by driving the phase modulators with step-recovery diodes where each comb consisted of > 250 teeth with 203 MHz spacing and spanned > 50 GHz region in the near-infrared. The step-recovery diodes are passive devices that provide low-phase-noise harmonics for efficient coupling into an enhancement cavity at picowatt optical powers. With this approach, we demonstrate the sensitivity to simultaneously monitor ambient levels of CO2, CO, HDO, and H2O in a single spectral region at a maximum acquisition rate of 150 kHz. Robust, compact, low-cost and widely tunable dual-comb systems could enable a network of distributed multiplexed optical sensors.

preprint2016arXiv

Multiplexed sub-Doppler spectroscopy with an optical frequency comb

An optical frequency comb generated with an electro-optic phase modulator and a chirped radiofrequency waveform is used to perform saturation and pump-probe spectroscopy on the $D_1$ and $D_2$ transitions of atomic potassium. With a comb tooth spacing of 200 kHz and an optical bandwidth of 2 GHz the hyperfine transitions can be simultaneously observed. Interferograms are recorded in as little as 5 $μ$s (a timescale corresponding to the inverse of the comb tooth spacing). Importantly, the sub-Doppler features can be measured as long as the laser carrier frequency lies within the Doppler profile, thus removing the need for slow scanning or a priori knowledge of the frequencies of the sub-Doppler features. Sub-Doppler optical frequency comb spectroscopy has the potential to dramatically reduce acquisition times and allow for rapid and accurate assignment of complex molecular and atomic spectra which are presently intractable.

preprint2015arXiv

High accuracy CO$_2$ line intensities determined from theory and experiment

Atmospheric CO$_2$ concentrations are being closely monitored by remote sensing experiments which rely on knowing line intensities with an uncertainty of 0.5\%\ or better. Most available laboratory measurements have uncertainties much larger than this. We report a joint experimental and theoretical study providing rotation-vibration line intensities with the required accuracy. The {\it ab initio} calculations are extendible to all atmospherically important bands of CO$_2$ and to its isotologues. As such they will form the basis for detailed CO$_2$ spectroscopic line lists for future studies.

preprint2014arXiv

Recommended isolated-line profile for representing high-resolution spectroscopic transitions (IUPAC Technical Report)

The report of an IUPAC Task Group, formed in 2011 on "Intensities and line shapes in high-resolution spectra of water isotopologues from experiment and theory" (Project No. 2011-022-2-100), on line profiles of isolated high-resolution rotational-vibrational transitions perturbed by neutral gas-phase molecules is presented. The well-documented inadequacies of the Voigt profile (VP), used almost universally by databases and radiative-transfer codes, to represent pressure effects and Doppler broadening in isolated vibrational-rotational and pure rotational transitions of the water molecule have resulted in the development of a variety of alternative line-profile models. These models capture more of the physics of the influence of pressure on line shapes but, in general, at the price of greater complexity. The Task Group recommends that the partially Correlated quadratic-Speed-Dependent Hard-Collision profile should be adopted as the appropriate model for high-resolution spectroscopy. For simplicity this should be called the Hartmann--Tran profile (HTP). The HTP is sophisticated enough to capture the various collisional contributions to the isolated line shape, can be computed in a straightforward and rapid manner, and reduces to simpler profiles, including the Voigt profile, under certain simplifying assumptions.