Abstract

In this paper we present the time resolution measurements of the Lutetium-Yttrium Oxyorthosilicate (LYSO) calorimeter prototype for the Mu2e experiment. The measurements have been performed using the e−e^- beam of the Beam Test Facility (BTF) in Frascati, Italy in the energy range from 100 to 400 MeV. The calorimeter prototype consisted of twenty five 30x30x130 mm3^3, LYSO crystals read out by 10x10 mm2^2 Hamamatsu Avalanche Photodiodes (APDs). The energy dependence of the measured time resolution can be parametrized as σt(E)=a/E/GeV⊕bσ_{t}(E)=a/\sqrt{E/\mathrm{GeV}} \oplus b, with the stochastic and constant terms a=(51±1)a=(51\pm1) ps and b=(10±4)b=(10\pm4) ps, respectively. This corresponds to the time resolution of (162±4162\pm4) ps at 100 MeV.