Researcher profile

V. Baranov

V. Baranov contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
6works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2026arXiv

Measurement of muon neutrino induced charged current interactions without charged pions in the final state using a new T2K off-axis near detector WAGASCI-BabyMIND

We report a flux-integrated cross section measurement of muon neutrino interactions on water and hydrocarbon via charged current reactions without charged pions in the final state with the WAGASCI-BabyMIND detector which was installed in the T2K near detector hall in 2018. The detector is located 1.5$^\circ$ off-axis and is exposed to a more energetic neutrino flux than ND280, another T2K near detector, which is located at a different off-axis position. The total flux-integrated cross section is measured to be $1.26 \pm 0.18\,(stat.+syst.) \times 10^{-39} $ $\mathrm{cm^{2}/nucleon}$ on CH and $1.44 \pm 0.21\,(stat.+syst.) \times 10^{-39} $ $\mathrm{cm^{2}/nucleon}$ on H$_{2}$O. These results are compared to model predictions provided by the NEUT v5.3.2 and GENIE v2.8.0 MC generators and the measurements are compatible with these models. Differential cross sections in muon momentum and cosine of the muon scattering angle are also reported. This is the first such measurement reported with the WAGASCI-BabyMIND detector and utilizes the 2020 and 2021 datasets.

preprint2025arXiv

Results from the T2K experiment on neutrino mixing including a new far detector $μ$-like sample

We have made improved measurements of three-flavor neutrino mixing with 19.7(16.3)$\times 10^{20}$ protons on target in (anti-)neutrino-enhanced beam modes. A new sample of muon-neutrino events with tagged pions has been added at the far detector, as well as new proton and photon-tagged samples at the near detector. Significant improvements have been made to the flux and neutrino interaction modeling. T2K data continue to prefer the normal mass ordering and upper octant of $\sin^2θ_{23}$ with a near-maximal value of the charge-parity violating phase with best-fit values in the normal ordering of $δ_{\scriptscriptstyle\mathrm{CP}}=-2.18\substack{+1.22 \\ -0.47}$, $\sin^2θ_{23}=0.559\substack{+0.018 \\ -0.078}$ and $Δm^2_{32}=(+2.506\substack{+0.039 \\ -0.052})\times 10^{-3}$ eV$^{2}$.

preprint2024arXiv

A search for $μ^+\to e^+γ$ with the first dataset of the MEG II experiment

The MEG II experiment, based at the Paul Scherrer Institut in Switzerland, reports the result of a search for the decay $μ^+\to e^+γ$ from data taken in the first physics run in 2021. No excess of events over the expected background is observed, yielding an upper limit on the branching ratio of B($μ^+\to e^+γ$) < $7.5 \times 10^{-13}$ (90% C.L.). The combination of this result and the limit obtained by MEG gives B($μ^+\to e^+γ$) < $3.1 \times 10^{-13}$ (90% C.L.), which is the most stringent limit to date. A ten-fold larger sample of data is being collected during the years 2022-2023, and data-taking will continue in the coming years.

preprint2024arXiv

Operation and performance of MEG II detector

The MEG II experiment, located at the Paul Scherrer Institut (PSI) in Switzerland, is the successor to the MEG experiment, which completed data taking in 2013. MEG II started fully operational data taking in 2021, with the goal of improving the sensitivity of the mu+ -> e+ gamma decay down to 6e-14 almost an order of magnitude better than the current limit. In this paper, we describe the operation and performance of the experiment and give a new estimate of its sensitivity versus data acquisition time.

preprint2023arXiv

SuperFGD prototype time resolution studies

The SuperFGD will be a part of the ND280 near detector of the T2K and Hyper Kamiokande projects, that will help to reduce systematic uncertainties related with neutrino flux and cross-section modeling. The upgraded ND280 will be able to perform a full exclusive reconstruction of the final state from neutrino-nucleus interactions, including measurements of low momentum protons, pions and, for the first time, event-by event measurements of neutron kinematics. The time resolution defines the neutron energy resolution. We present the results of time resolution measurements made with the SuperFGD prototype that consists of 9216 plastic scintillator cubes (cube size is 1 cm$^3$) readout with 1728 wavelength-shifting fibers going along three orthogonal directions. We use data from the muon beam exposure at CERN. The time resolution of 0.97 ns was obtained for one readout channel after implementing the time calibration with a correction for the time-walk effect. The time resolution improves with energy deposited in a scintillator cube. Averaging two readout channels for one scintillator cube improves the time resolution to 0.68 ns which means that signals in different channels are not synchronous. Therefore the contribution from the time recording step of 2.5 ns is averaged as well. Averaging time values from N channels improves the time resolution by $\sim 1/\sqrt{N}$. Therefore a very good time resolution should be achievable for neutrons since neutron recoils hit typically several scintillator cubes and in addition produce larger amplitudes than muons. Measurements performed with a laser and a wide-bandwidth oscilloscope demonstrated that the time resolution obtained with the muon beam is not far from its expected limit. The intrinsic time resolution of one channel is 0.67 ns for signals of 56 photo-electron typical for minimum ionizing particles.

preprint2021arXiv

Light outputs of yttrium doped BaF$_2$ crystals irradiated with neutrons

The fast luminescence component of barium fluoride (BaF$_2$) crystals with a subnanosecond decay time can find wide application in particle physics and nuclear physics. However, the slow luminescence component with the 630~ns decay time could cause pile-up signals at a high rate environment. Doping of BaF$_2$ crystals with rare earth elements suppresses the slow emission component, but at the same time the radiation hardness of the crystals deteriorates. This work presents the results of studying crystal samples, both pure BaF$_2$ and those doped with yttrium in a proportion of 1at.\%Y, 3at.\%Y and 5at.\%Y, irradiated with a fast neutron fluence of about 2.3$\times$10$^{14}$~n/cm$^2$. Their light output and decay kinetics were measured before and after irradiation. It is found that the light output loss of a pure BaF$_2$ crystal after irradiation is about 7\%, and the light output loss of yttrium doped samples after irradiation is about two times higher. The measurement results demonstrate that after irradiation the fast component of each sample has a relative light output loss 2-3\% larger than the slow one.