Source author record

V. Baranov

V. Baranov appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

13works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

13 published item(s)

preprint2026arXiv

Measurement of muon neutrino induced charged current interactions without charged pions in the final state using a new T2K off-axis near detector WAGASCI-BabyMIND

We report a flux-integrated cross section measurement of muon neutrino interactions on water and hydrocarbon via charged current reactions without charged pions in the final state with the WAGASCI-BabyMIND detector which was installed in the T2K near detector hall in 2018. The detector is located 1.5$^\circ$ off-axis and is exposed to a more energetic neutrino flux than ND280, another T2K near detector, which is located at a different off-axis position. The total flux-integrated cross section is measured to be $1.26 \pm 0.18\,(stat.+syst.) \times 10^{-39} $ $\mathrm{cm^{2}/nucleon}$ on CH and $1.44 \pm 0.21\,(stat.+syst.) \times 10^{-39} $ $\mathrm{cm^{2}/nucleon}$ on H$_{2}$O. These results are compared to model predictions provided by the NEUT v5.3.2 and GENIE v2.8.0 MC generators and the measurements are compatible with these models. Differential cross sections in muon momentum and cosine of the muon scattering angle are also reported. This is the first such measurement reported with the WAGASCI-BabyMIND detector and utilizes the 2020 and 2021 datasets.

preprint2025arXiv

Results from the T2K experiment on neutrino mixing including a new far detector $μ$-like sample

We have made improved measurements of three-flavor neutrino mixing with 19.7(16.3)$\times 10^{20}$ protons on target in (anti-)neutrino-enhanced beam modes. A new sample of muon-neutrino events with tagged pions has been added at the far detector, as well as new proton and photon-tagged samples at the near detector. Significant improvements have been made to the flux and neutrino interaction modeling. T2K data continue to prefer the normal mass ordering and upper octant of $\sin^2θ_{23}$ with a near-maximal value of the charge-parity violating phase with best-fit values in the normal ordering of $δ_{\scriptscriptstyle\mathrm{CP}}=-2.18\substack{+1.22 \\ -0.47}$, $\sin^2θ_{23}=0.559\substack{+0.018 \\ -0.078}$ and $Δm^2_{32}=(+2.506\substack{+0.039 \\ -0.052})\times 10^{-3}$ eV$^{2}$.

preprint2024arXiv

A search for $μ^+\to e^+γ$ with the first dataset of the MEG II experiment

The MEG II experiment, based at the Paul Scherrer Institut in Switzerland, reports the result of a search for the decay $μ^+\to e^+γ$ from data taken in the first physics run in 2021. No excess of events over the expected background is observed, yielding an upper limit on the branching ratio of B($μ^+\to e^+γ$) < $7.5 \times 10^{-13}$ (90% C.L.). The combination of this result and the limit obtained by MEG gives B($μ^+\to e^+γ$) < $3.1 \times 10^{-13}$ (90% C.L.), which is the most stringent limit to date. A ten-fold larger sample of data is being collected during the years 2022-2023, and data-taking will continue in the coming years.

preprint2024arXiv

Operation and performance of MEG II detector

The MEG II experiment, located at the Paul Scherrer Institut (PSI) in Switzerland, is the successor to the MEG experiment, which completed data taking in 2013. MEG II started fully operational data taking in 2021, with the goal of improving the sensitivity of the mu+ -> e+ gamma decay down to 6e-14 almost an order of magnitude better than the current limit. In this paper, we describe the operation and performance of the experiment and give a new estimate of its sensitivity versus data acquisition time.

preprint2023arXiv

SuperFGD prototype time resolution studies

The SuperFGD will be a part of the ND280 near detector of the T2K and Hyper Kamiokande projects, that will help to reduce systematic uncertainties related with neutrino flux and cross-section modeling. The upgraded ND280 will be able to perform a full exclusive reconstruction of the final state from neutrino-nucleus interactions, including measurements of low momentum protons, pions and, for the first time, event-by event measurements of neutron kinematics. The time resolution defines the neutron energy resolution. We present the results of time resolution measurements made with the SuperFGD prototype that consists of 9216 plastic scintillator cubes (cube size is 1 cm$^3$) readout with 1728 wavelength-shifting fibers going along three orthogonal directions. We use data from the muon beam exposure at CERN. The time resolution of 0.97 ns was obtained for one readout channel after implementing the time calibration with a correction for the time-walk effect. The time resolution improves with energy deposited in a scintillator cube. Averaging two readout channels for one scintillator cube improves the time resolution to 0.68 ns which means that signals in different channels are not synchronous. Therefore the contribution from the time recording step of 2.5 ns is averaged as well. Averaging time values from N channels improves the time resolution by $\sim 1/\sqrt{N}$. Therefore a very good time resolution should be achievable for neutrons since neutron recoils hit typically several scintillator cubes and in addition produce larger amplitudes than muons. Measurements performed with a laser and a wide-bandwidth oscilloscope demonstrated that the time resolution obtained with the muon beam is not far from its expected limit. The intrinsic time resolution of one channel is 0.67 ns for signals of 56 photo-electron typical for minimum ionizing particles.

preprint2021arXiv

Light outputs of yttrium doped BaF$_2$ crystals irradiated with neutrons

The fast luminescence component of barium fluoride (BaF$_2$) crystals with a subnanosecond decay time can find wide application in particle physics and nuclear physics. However, the slow luminescence component with the 630~ns decay time could cause pile-up signals at a high rate environment. Doping of BaF$_2$ crystals with rare earth elements suppresses the slow emission component, but at the same time the radiation hardness of the crystals deteriorates. This work presents the results of studying crystal samples, both pure BaF$_2$ and those doped with yttrium in a proportion of 1at.\%Y, 3at.\%Y and 5at.\%Y, irradiated with a fast neutron fluence of about 2.3$\times$10$^{14}$~n/cm$^2$. Their light output and decay kinetics were measured before and after irradiation. It is found that the light output loss of a pure BaF$_2$ crystal after irradiation is about 7\%, and the light output loss of yttrium doped samples after irradiation is about two times higher. The measurement results demonstrate that after irradiation the fast component of each sample has a relative light output loss 2-3\% larger than the slow one.

preprint2016arXiv

Design and status of the Mu2e electromagnetic calorimeter

The Mu2e experiment at Fermilab aims at measuring the neutrinoless conversion of a negative muon into an electron and reach a single event sensitivity of 2.5x10^{-17} after three years of data taking. The monoenergetic electron produced in the final state, is detected by a high precision tracker and a crystal calorimeter, all embedded in a large superconducting solenoid (SD) surrounded by a cosmic ray veto system. The calorimeter is complementary to the tracker, allowing an independent trigger and powerful particle identification, while seeding the track reconstruction and contributing to remove background tracks mimicking the signal. In order to match these requirements, the calorimeter should have an energy resolution of O(5)% and a time resolution better than 500 ps at 100 MeV. The baseline solution is a calorimeter composed of two disks of BaF2 crystals read by UV extended, solar blind, Avalanche Photodiode (APDs), which are under development from a JPL, Caltech, RMD consortium. In this paper, the calorimeter design, the R&D studies carried out so far and the status of engineering are described. A backup alternative setup consisting of a pure CsI crystal matrix read by UV extended Hamamatsu MPPC's is also presented.

preprint2016arXiv

Measurement of time resolution of the Mu2e LYSO calorimeter prototype

In this paper we present the time resolution measurements of the Lutetium-Yttrium Oxyorthosilicate (LYSO) calorimeter prototype for the Mu2e experiment. The measurements have been performed using the $e^-$ beam of the Beam Test Facility (BTF) in Frascati, Italy in the energy range from 100 to 400 MeV. The calorimeter prototype consisted of twenty five 30x30x130 mm$^3$, LYSO crystals read out by 10x10 mm$^2$ Hamamatsu Avalanche Photodiodes (APDs). The energy dependence of the measured time resolution can be parametrized as $σ_{t}(E)=a/\sqrt{E/\mathrm{GeV}} \oplus b$, with the stochastic and constant terms $a=(51\pm1)$ ps and $b=(10\pm4)$ ps, respectively. This corresponds to the time resolution of ($162\pm4$) ps at 100 MeV.

preprint2016arXiv

The increase of the light collection from scintillation strip with hole for WLS fiber using various types of fillers

The light collection of the extruded scintillator strip samples with WLS fibers placed in the longitudinal hole in the plates was measured. The holes were filled with various liquid fillers. Measurements were carried out under irradiation by cosmic muons. The method of pumping liquid filler with viscosity more than 10 Pa*s in the strip hole with WLS fiber inside was designed and successfully tested.

preprint2015arXiv

Performance of Scintillator Counters with Silicon Photomultiplier Readout

The performance of scintillator counters with embedded wavelength-shifting fibers has been measured in the Fermilab Meson Test Beam Facility using 120 GeV protons. The counters were extruded with a titanium dioxide surface coating and two channels for fibers at the Fermilab NICADD facility. Each fiber end is read out by a 2*2 mm^2 silicon photomultiplier. The signals were amplified and digitized by a custom-made front-end electronics board. Combinations of 5*2 cm^2 and 6*2 cm^2 extrusion profiles with 1.4 and 1.8 mm diameter fibers were tested. The design is intended for the cosmic-ray veto detector for the Mu2e experiment at Fermilab. The light yield as a function of the transverse and longitudinal position of the beam will be given.

preprint2011arXiv

Study of the K0(L) --> pi0 pi0 nu nu-bar decay

The rare decay K0(L) --> pi0 pi0 nu nu-bar was studied with the E391a detector at the KEK 12-GeV proton synchrotron. Based on 9.4 x 10^9 K0L decays, an upper limit of 8.1 x 10^{-7} was obtained for the branching fraction at 90% confidence level. We also set a limit on the K0(L) --> pi0 pi0 X (X --> invisible particles) process; the limit on the branching fraction varied from 7.0 x 10^{-7} to 4.0 x 10^{-5} for the mass of X ranging from 50 MeV/c^2 to 200 MeV/c^2.

preprint2009arXiv

Search for a light pseudoscalar particle in the decay $K^0_L \to π^0 π^0 X$

We performed a search for a light pseudoscalar particle $X$ in the decay $K_L^0->pi0pi0X$, $X->γγ$ with the E391a detector at KEK. Such a particle with a mass of 214.3 MeV/$c^2$ was suggested by the HyperCP experiment. We found no evidence for $X$ and set an upper limit on the product branching ratio for $K_L^0->pi0pi0X$, $X->γγ$ of $2.4 \times 10^{-7}$ at the 90% confidence level. Upper limits on the branching ratios in the mass region of $X$ from 194.3 to 219.3 MeV/$c^2$ are also presented.