Paper detail

Design of the AGIPD Sensor for the European XFEL

For experiments at the European X-Ray Free-Electron Laser (XFEL) the Adaptive Gain Integrating Pixel Detector (AGIPD) is under development. The particular requirements for the detector are a high dynamic range of 0, 1 - to more than 10E4 12.4 keV photons per pixel within an XFEL pulse duration of < 100 fs, and a radiation tolerance of doses up to 1 GGy for 3 years of operation. The detector will have 1024 x 1024 p+ pixels with a pixel size of 200 um x 200 um and will be manufactured on 500 um thick n-type silicon. The design value for the operating voltage is 500 V, however, for special applications an operation up to ~ 1000 V should be possible. Experimental data on the dose dependence of the surface density of oxide charges at the Si-SiO2 interface and the surface-current density have been implemented in the SYNOPSYS TCAD simulation program in order to optimize the design of the pixel and guard-ring layout. The methodology of the sensor design, the optimization of the most relevant parameters and the layout are demonstrated. Finally the simulated performance, in particular the breakdown voltage, dark current and inter-pixel capacitance as function of the X-ray dose will be presented.

preprint2012arXivOpen access

Signal facts

What is known right now

Open access4 authors1 topic

Next steps

Decide what to do with this paper

Use like or dislike for the fast social read. The more specific scholarly feedback stays available below when needed.

Log in to curate

Reading frame

Keep the important context close to the paper

Keep the important signals around this paper in one place: votes, save state, collection context, reviews and the metadata you need before deciding what to do next.

Institutions

Add specific reaction

Move through the context

Research map

Open full explorer

Move through nearby people, institutions, topics and adjacent work without leaving the paper page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Structured reviews

0 review(s)

ContributeLeave structured feedbackUse the review template when you have a concrete strength, concern or method question.Open review form

No structured reviews yet. High-signal critique starts here.

Work discussion

0 comment(s)

DiscussAdd a high-signal commentKeep quick notes, caveats and replication pointers separate from formal reviews.Open comment form

No discussion yet. The first strong comment sets the tone.