Researcher profile

Zhou Wang

Zhou Wang contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
19works
0followers
9topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

19 published item(s)

preprint2026arXiv

GPS-Synchronized Monitoring of Core-collapse Supernova Bursts with PandaX-4T via Coherent Elastic Neutrino Nuclear Scattering

The landmark detection of neutrinos from SN1987A marked the dawn of neutrino astrophysics. The neutrino burst provided essential insights into fundamental properties of neutrinos, and served as key probes of stellar evolution and supernova dynamics. The recent advancement in coherent elastic neutrino-nucleus scattering enables the detection of core-collapse supernova burst neutrinos using tonne-scale liquid xenon detectors originally designed for dark matter direct detection. Leveraging this capability, we developed and deployed an online supernova monitoring system for the PandaX-4T experiment. This system features a GPS module with millisecond-level timing precision, a low false-alarm rate, and high sensitivity to galactic core-collapse supernova explosion events. The methodology is robust, directly scalable, and planned for implementation in the next-generation PandaX-20T experiment.

preprint2023arXiv

A First Search for Solar $^8$B Neutrino in the PandaX-4T Experiment using Neutrino-Nucleus Coherent Scattering

A search for interactions from solar $^8$B neutrinos elastically scattering off xenon nuclei using PandaX-4T commissioning data is reported. The energy threshold of this search is further lowered compared with the previous search for dark matter, with various techniques utilized to suppress the background that emerges from data with the lowered threshold. A blind analysis is performed on the data with an effective exposure of 0.48 tonne$\cdot$year, and no significant excess of events is observed. Among results obtained using the neutrino-nucleus coherent scattering, our results give the best constraint on the solar $^8$B neutrino flux. We further provide a more stringent limit on the cross section between dark matter and nucleon in the mass range from 3 to 9 GeV/c$^2$.

preprint2022arXiv

A Search for the Cosmic Ray Boosted Sub-GeV Dark Matter at the PandaX-II Experiment

We report a novel search for the cosmic ray boosted dark matter using the 100~tonne$\cdot$day full data set of the PandaX-II detector located at the China Jinping Underground Laboratory. With the extra energy gained from the cosmic rays, sub-GeV dark matter particles can produce visible recoil signals in the detector. The diurnal modulations in rate and energy spectrum are utilized to further enhance the signal sensitivity. Our result excludes the dark matter-nucleon elastic scattering cross section between 10$^{-31}$cm$^{2}$ and 10$^{-28}$cm$^{2}$ for a dark matter masses from 0.1 MeV/$c^2$ to 0.1 GeV/$c^2$, with a large parameter space previously unexplored by experimental collaborations.

preprint2022arXiv

A search for two-component Majorana dark matter in a simplified model using the full exposure data of PandaX-II experiment

In the two-component Majorana dark matter model, one dark matter particle can scatter off the target nuclei, and turn into a slightly heavier component. In the framework of a simplified model with a vector boson mediator, both the tree-level and loop-level processes contribute to the signal in direct detection experiment. In this paper, we report the search results for such dark matter from PandaX-II experiment, using total data of the full 100.7 tonne$\cdot$day exposure. No significant excess is observed, so strong constraints on the combined parameter space of mediator mass and dark matter mass are derived. With the complementary search results from collider experiments, a large range of parameter space can be excluded.

preprint2022arXiv

Design and Operation of the PandaX-4T High Speed Ultra-high Purity Xenon Recuperation System

In order to recuperate the ultra-high purity xenon from PandaX-4T dark matter detector to high-pressure gas cylinders in emergency or at the end-of-run situation, a high speed ultra-high purity xenon recuperation system is designed and developed. This system includes a diaphragm pump, the heat management system, the main recuperation pipeline, the reflux pipeline, the auxiliary recuperation pipeline and the automatic control system. The liquid xenon in the detector is vaporized by the heat management system, and the gaseous xenon is compressed to 6 MPa at the flow rate of 200 standard litres per minute (SLPM) using the diaphragm compressor. The high-pressure xenon is filled into 128 gas cylinders via the main recuperation pipeline. During the recuperation, the low pressure and temperature conditions of 2 ~ 3 atmospheres and 178 ~ 186.5 K in PandaX-4T dark matter detector are kept by the cooperation of the main recuperation pipeline, reflux pipeline and the auxiliary recuperation pipeline to guarantee the safety, and the purity of the recuperated xenon gas is measured to ensure no contamination happened. The development of the high speed ultra-high purity xenon recuperation system is important for the operation of large-scale dark matter detectors with the requirements of strict temperature and pressure environment and low background.

preprint2022arXiv

Low Radioactive Material Screening and Background Control for the PandaX-4T Experiment

PandaX-4T is a ton-scale dark matter direct detection experiment using a dual-phase TPC technique at the China Jinping Underground Laboratory. Various ultra-low background technologies have been developed and applied to material screening for PandaX-4T, including HPGe gamma spectroscopy, ICP-MS, NAA, radon emanation measurement system, krypton assay station, and alpha detection system. Low background materials were selected to assemble the detector. Surface treatment procedures were investigated to further suppress radioactive background. Combining measured results and Monte Carlo simulation, the total material background rates of PandaX-4T in the energy region of 1-25 keV$\rm{}_{ee}$ are estimated to be (9.9 $\pm$ 1.9) $\times \ 10^{-3}$ mDRU for electron recoil and (2.8 $\pm$ 0.6) $\times \ 10^{-4}$ mDRU for nuclear recoil. In addition, $^{nat}$Kr in the detector is estimated to be <8 ppt.

preprint2022arXiv

Neutron-induced nuclear recoil background in the PandaX-4T experiment

Neutron-induced nuclear recoil background is critical to the dark matter searches in the PandaX-4T liquid xenon experiment. This paper studies the feature of neutron background in liquid xenon and evaluates their contribution in the single scattering nuclear recoil events through three methods. The first method is fully Monte Carlo simulation based. The last two are data-driven methods that also use the multiple scattering signals and high energy signals in the data, respectively. In the PandaX-4T commissioning data with an exposure of 0.63 tonne-year, all these methods give a consistent result that there are $1.15\pm0.57$ neutron-induced background in dark matter signal region within an approximated nuclear recoil energy window between 5 and 100 keV.

preprint2022arXiv

Quality Assessment of Image Super-Resolution: Balancing Deterministic and Statistical Fidelity

There has been a growing interest in developing image super-resolution (SR) algorithms that convert low-resolution (LR) to higher resolution images, but automatically evaluating the visual quality of super-resolved images remains a challenging problem. Here we look at the problem of SR image quality assessment (SR IQA) in a two-dimensional (2D) space of deterministic fidelity (DF) versus statistical fidelity (SF). This allows us to better understand the advantages and disadvantages of existing SR algorithms, which produce images at different clusters in the 2D space of (DF, SF). Specifically, we observe an interesting trend from more traditional SR algorithms that are typically inclined to optimize for DF while losing SF, to more recent generative adversarial network (GAN) based approaches that by contrast exhibit strong advantages in achieving high SF but sometimes appear weak at maintaining DF. Furthermore, we propose an uncertainty weighting scheme based on content-dependent sharpness and texture assessment that merges the two fidelity measures into an overall quality prediction named the Super Resolution Image Fidelity (SRIF) index, which demonstrates superior performance against state-of-the-art IQA models when tested on subject-rated datasets.

preprint2022arXiv

Study of background from accidental coincidence signals in the PandaX-II experiment

The PandaX-II experiment employed a 580kg liquid xenon detector to search for the interactions between dark matter particles and the target xenon atoms. The accidental coincidences of isolated signals result in a dangerous background which mimic the signature of the dark matter. We performed a detailed study on the accidental coincidence background in PandaX-II, including the possible origin of the isolated signals, the background level and corresponding background suppression method. With a boosted-decision-tree algorithm, the accidental coincidence background is reduced by 70% in the dark matter signal region, thus the sensitivity of dark matter search at PandaX-II is improved.

preprint2021arXiv

Dark Matter Search Results from the PandaX-4T Commissioning Run

We report the first dark matter search results using the commissioning data from PandaX-4T. Using a time projection chamber with 3.7-tonne of liquid xenon target and an exposure of 0.63 tonne$\cdot$year, 1058 candidate events are identified within an approximate nuclear recoil energy window between 5 and 100 keV. No significant excess over background is observed. Our data set a stringent limit to the dark matter-nucleon spin-independent interactions, with a lowest excluded cross section (90% C.L.) of $3.8\times10^{-47} $cm$^2$ at a dark matter mass of 30 GeV/$c^2$.

preprint2021arXiv

Experimental Analysis of PandaX-4T Cryogenic Distillation System for Removing Krypton from Xenon

An efficient cryogenic distillation system was designed and constructed for PandaX-4T dark matter detector based on the McCabe-Thiele (M-T) method and the conservation of mass and energy. This distillation system is designed to reduce the concentration of krypton in commercial xenon from 5X$10^{-7}$ mol/mol to $10^{-14}$ mol/mol with 99% xenon collection efficiency at a maximum flow rate of 10 kg/h. The offline distillation operation has been completed and 5.75 tons of ultra-high purity xenon was produced, which is used as the detection medium in PandaX-4T detector. The krypton concentration of the product xenon is measured with an upper limit of 8.0 ppt. The stability and purification performance of the cryogenic distillation system are studied by analyzing the experimental data, which is important for theoretical research and distillation operation optimization.

preprint2021arXiv

Internal Calibration of the PandaX-II Detector with Radon Gaseous Sources

We have developed a low-energy electron recoil (ER) calibration method with $^{220}$Rn for the PandaX-II detector. $^{220}$Rn, emanated from natural thorium compounds, was fed into the detector through the xenon purification system. From 2017 to 2019, we performed three dedicated calibration campaigns with different radon sources. We studied the detector response to $α$, $β$, and $γ$ particles with focus on low energy ER events. During the runs in 2017 and 2018, the amount of radioactivity of $^{222}$Rn were on the order of 1\% of that of $^{220}$Rn and thorium particulate contamination was negligible, especially in 2018. We also measured the background contribution from $^{214}$Pb for the first time in PandaX-II with the help from a $^{222}$Rn injection. Calibration strategy with $^{220}$Rn and $^{222}$Rn will be implemented in the upcoming PandaX-4T experiment and can be useful for other xenon-based detectors as well.

preprint2021arXiv

Light yield and field dependence measurement in PandaX-II dual-phase xenon detector

The dual-phase xenon time projection chamber (TPC) is one of the most sensitive detector technology for dark matter direct search, where the energy deposition of incoming particle can be converted into photons and electrons through xenon excitation and ionization. The detector response to signal energy deposition varies significantly with the electric field in liquid xenon. We study the detector&#39;s light yield and its dependence on the electric field in the PandaX-II dual-phase detector containing 580~kg liquid xenon in the sensitive volume. From our measurements, the light yield at electric fields from 0~V/cm to 317~V/cm is obtained for energy depositions up to 236~keV.

preprint2021arXiv

Quantifying Visual Image Quality: A Bayesian View

Image quality assessment (IQA) models aim to establish a quantitative relationship between visual images and their perceptual quality by human observers. IQA modeling plays a special bridging role between vision science and engineering practice, both as a test-bed for vision theories and computational biovision models, and as a powerful tool that could potentially make profound impact on a broad range of image processing, computer vision, and computer graphics applications, for design, optimization, and evaluation purposes. IQA research has enjoyed an accelerated growth in the past two decades. Here we present an overview of IQA methods from a Bayesian perspective, with the goals of unifying a wide spectrum of IQA approaches under a common framework and providing useful references to fundamental concepts accessible to vision scientists and image processing practitioners. We discuss the implications of the successes and limitations of modern IQA methods for biological vision and the prospect for vision science to inform the design of future artificial vision systems.

preprint2021arXiv

Results of Dark Matter Search using the Full PandaX-II Exposure

We report the dark matter search results obtained using the full 132 ton$\cdot$day exposure of the PandaX-II experiment, including all data from March 2016 to August 2018. No significant excess of events is identified above the expected background. Upper limits are set on the spin-independent dark matter-nucleon interactions. The lowest 90% confidence level exclusion on the spin-independent cross section is $2.2\times 10^{-46}$ cm$^2$ at a WIMP mass of 30 GeV/$c^2$.

preprint2020arXiv

Assessing the Quality-of-Experience of Adaptive Bitrate Video Streaming

The diversity of video delivery pipeline poses a grand challenge to the evaluation of adaptive bitrate (ABR) streaming algorithms and objective quality-of-experience (QoE) models. Here we introduce so-far the largest subject-rated database of its kind, namely WaterlooSQoE-IV, consisting of 1350 adaptive streaming videos created from diverse source contents, video encoders, network traces, ABR algorithms, and viewing devices. We collect human opinions for each video with a series of carefully designed subjective experiments. Subsequent data analysis and testing/comparison of ABR algorithms and QoE models using the database lead to a series of novel observations and interesting findings, in terms of the effectiveness of subjective experiment methodologies, the interactions between user experience and source content, viewing device and encoder type, the heterogeneities in the bias and preference of user experiences, the behaviors of ABR algorithms, and the performance of objective QoE models. Most importantly, our results suggest that a better objective QoE model, or a better understanding of human perceptual experience and behaviour, is the most dominating factor in improving the performance of ABR algorithms, as opposed to advanced optimization frameworks, machine learning strategies or bandwidth predictors, where a majority of ABR research has been focused on in the past decade. On the other hand, our performance evaluation of 11 QoE models shows only a moderate correlation between state-of-the-art QoE models and subjective ratings, implying rooms for improvement in both QoE modeling and ABR algorithms. The database is made publicly available at: \url{https://ece.uwaterloo.ca/~zduanmu/waterloosqoe4/}.

preprint2020arXiv

Characterizing Generalized Rate-Distortion Performance of Video Coding: An Eigen Analysis Approach

Rate-distortion (RD) theory is at the heart of lossy data compression. Here we aim to model the generalized RD (GRD) trade-off between the visual quality of a compressed video and its encoding profiles (e.g., bitrate and spatial resolution). We first define the theoretical functional space $\mathcal{W}$ of the GRD function by analyzing its mathematical properties.We show that $\mathcal{W}$ is a convex set in a Hilbert space, inspiring a computational model of the GRD function, and a method of estimating model parameters from sparse measurements. To demonstrate the feasibility of our idea, we collect a large-scale database of real-world GRD functions, which turn out to live in a low-dimensional subspace of $\mathcal{W}$. Combining the GRD reconstruction framework and the learned low-dimensional space, we create a low-parameter eigen GRD method to accurately estimate the GRD function of a source video content from only a few queries. Experimental results on the database show that the learned GRD method significantly outperforms state-of-the-art empirical RD estimation methods both in accuracy and efficiency. Last, we demonstrate the promise of the proposed model in video codec comparison.

preprint2019arXiv

Modeling Generalized Rate-Distortion Functions

Many multimedia applications require precise understanding of the rate-distortion characteristics measured by the function relating visual quality to media attributes, for which we term it the generalized rate-distortion (GRD) function. In this study, we explore the GRD behavior of compressed digital videos in a three-dimensional space of bitrate, resolution, and viewing device/condition. Our analysis on a large-scale video dataset reveals that empirical parametric models are systematically biased while exhaustive search methods require excessive computation time to depict the GRD surfaces. By exploiting the properties that all GRD functions share, we develop an Robust Axial-Monotonic Clough-Tocher (RAMCT) interpolation method to model the GRD function. This model allows us to accurately reconstruct the complete GRD function of a source video content from a moderate number of measurements. To further reduce the computational cost, we present a novel sampling scheme based on a probabilistic model and an information measure. The proposed sampling method constructs a sequence of quality queries by minimizing the overall informativeness in the remaining samples. Experimental results show that the proposed algorithm significantly outperforms state-of-the-art approaches in accuracy and efficiency. Finally, we demonstrate the usage of the proposed model in three applications: rate-distortion curve prediction, per-title encoding profile generation, and video encoder comparison.

preprint2019arXiv

Searching for Neutrino-less Double Beta Decay of $^{136}$Xe with PandaX-II Liquid Xenon Detector

We report the Neutrino-less Double Beta Decay (NLDBD) search results from PandaX-II dual-phase liquid xenon time projection chamber. The total live time used in this analysis is 403.1 days from June 2016 to August 2018. With NLDBD-optimized event selection criteria, we obtain a fiducial mass of 219 kg of natural xenon. The accumulated xenon exposure is 242 kg$\cdot$yr, or equivalently 22.2 kg$\cdot$yr of $^{136}$Xe exposure. At the region around $^{136}$Xe decay Q-value of 2458 keV, the energy resolution of PandaX-II is 4.2%. We find no evidence of NLDBD in PandaX-II and establish a lower limit for decay half-life of 2.4 $ \times 10^{23} $ yr at the 90% confidence level, which corresponds to an effective Majorana neutrino mass $m_{ββ} < (1.3 - 3.5)$ eV. This is the first NLDBD result reported from a dual-phase xenon experiment.