Researcher profile

Yi-Dong Zhao

Yi-Dong Zhao contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - Baseline
3works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2015arXiv

Vacuum ultraviolet photon detector with continuously adjustable resolution for inverse photoemission spectroscopy

We present a vacuum ultraviolet (VUV) band-pass photon detector for inverse photoemission spectroscopy. A SrF2 window is used due to its high-energy cutoff of the optical transmission being 9.7eV, and acetone is selected as filling gas with the photoionization threshold also being 9.7eV. The structure of the detector described in detail is based on a Geiger-Müller type counter with an MgF2 window and argon as amplification gas. Its energy resolution can be tuned continuously from 46meV with a normal temperature situation to 105meV at 215K. Meanwhile, the signal intensity of the detector is adjusted accordingly to find an optimal operation program for our inverse photoemission system which is being constructed. The ratio of acetone vapor and argon is varied carefully. Background signals and the response of time are analyzed. The detector is normalized by deuterium lamp in combination with a grating monochromator.

preprint2014arXiv

A new method to suppress high-order harmonics for synchrotron radiation soft x-ray beamline

A feasible and convenient method has been proposed to suppress higher-harmonics for varied-line-spacing (VLS) plane grating monochromator in soft x-ray region. Related calculations and experiments demonstrate that decreasing the included angle slightly by changing the parameter of exit arm length can significantly improve light purity. This method is suitable and has been used for experiments of detector calibration in beamline 4B7B at Beijing Synchrotron Radiation Facility (BSRF).

preprint2014arXiv

A new soft X-ray magnetic circular dichroism facility at the BSRF beamline 4B7B

X-ray magnetic circular dichroism (XMCD) has become an important and powerful tool because it allows the study of material properties in combination with elemental specificity, chemical state specificity, and magnetic specificity. A new soft X-ray magnetic circular dichroism apparatus has been developed at the Beijing Synchrotron Radiation Facility (BSRF). The apparatus combines three experimental conditions: ultra-high-vacuum environment, moderate magnetic fields and in-situ sample preparation to measure the absorption signal. We designed a C type dipole electromagnet that provides magnetic fields up to 0.5T in parallel (or anti-parallel) direction relative to the incoming X-ray beam. The performances of the electromagnet are measured and the results show good agreement with the simulation ones. Following film grown in situ by evaporation methods, XMCD measurements are performed. Combined polarization corrections, the magnetic moments of the Fe and Co films determined by sum rules are consistent with other theoretical predictions and experimental measurements.