Source author record

Xavier Sarazin

Xavier Sarazin appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2021arXiv

The DeLLight experiment to observe an optically-induced change of the vacuum index

Quantum electrodynamics predicts that the vacuum must behave as a nonlinear optical medium: the speed of light should be modified when the vacuum is stressed by intense electromagnetic fields. This optical phenomenon has not yet been observed. The DeLLight (Deflection of Light by Light) experiment aims to observe the optically-induced index change of vacuum, a nonlinear effect which has never been explored. The experiment is installed in the LASERIX facility at IJCLab, which delivers ultra-short intense laser pulses (2.5 J per pulse, each of 30 fs duration, with a 10 Hz repetition rate). The proposal is to measure the refraction of a probe laser pulse when crossing a transverse vacuum index gradient, produced by a very intense pump pulse. The refraction induces a transverse shift in the intensity profile of the probe, whose signal is amplified by a Sagnac interferometer. In this article, we describe the experimental method and setup, and present the complete theoretical calculations for the expected signal. With a minimum waist at focus of $5 \,μ$m (corresponding to a maximum intensity of $\sim 3 \times 10^{20}$ W/cm$^2$), and with the nonlinear vacuum index derived from QED, the expected refraction angle is 0.13 prad. First results of the interferometer prototype are presented. It is shown that an extinction factor $\mathcal{F} = 0.4 \times 10^{-5}$ (corresponding to a signal amplification factor of 250) and a spatial resolution $σ_y = 10$ nm are achievable. The expected signal is then about 15 pm, and could be observed at a 5-sigma confidence level with about one month of collected data.

preprint2013arXiv

The quantum vacuum as the origin of the speed of light

We show that the vacuum permeability and permittivity may originate from the magnetization and the polarization of continuously appearing and disappearing fermion pairs. We then show that if we simply model the propagation of the photon in vacuum as a series of transient captures within these ephemeral pairs, we can derive a finite photon velocity. Requiring that this velocity is equal to the speed of light constrains our model of vacuum. Within this approach, the propagation of a photon is a statistical process at scales much larger than the Planck scale. Therefore we expect its time of flight to fluctuate. We propose an experimental test of this prediction.

preprint2012arXiv

Review of double beta experiments

This paper is the first part of the manuscript written in April 2012 for my academic Accreditation to supervise research. It offers a review of the double beta experimental techniques. My purpose is to detail, for each technique, the different origins of background, how they can be identified, and how they can be reduced. Advantages and limitations are discussed. This review is organized as follows. First, the question of the possible Majorana nature for the neutrino is presented and the physic of neutrinoless double beta decay is summarized. Then I begin by presenting the tracko-calo NEMO-3 and SuperNEMO experiments. I've worked on these two experiments since 15 years. So it was natural to start with them with a relatively more exhaustive description. I will then present the germanium technique. I will then review the bolometer technique. I will describe in detail the recent progress in scintillating bolometers because I think that it is one of the most promising techniques. Finally I will review the large liquid scintillator detectors and Xenon TPC. The last chapter offers a summary of the different techniques and projects.

preprint2009arXiv

Corpuscular description of the speed of light in a homogeneous medium

We are used to describe the detection of light in terms of particles and its propagation from the source to the detection, by waves. For instance, the slowing down of light in a transparent medium is always explained within the electromagnetic wave framework. We propose to approach that phenomenon through a purely corpuscular description. We find expression for the refractive indices which differ slightly from the usual Maxwell wave approach. We thus compare these expressions against experimental refractive indices and we show that both reproduce well the data. We show also how this corpuscular framework gives a very natural interpretation to the self focusing Kerr effect. Finally an experimental expectation of fluctuation of the speed of light is presented.

preprint2004arXiv

Search for neutrinoless double beta decay with the NEMO-3 detector: first results

The NEMO-3 detector, which has been operating in the Frejus Underground Laboratory since February 2003, is devoted to searching for neutrinoless double beta decay (ββ0 ν). The expected performance of the detector has been successfully achieved. Half-lives of the two neutrinos double beta decay (ββ2 ν$) have been measured for ^{100} Mo, ^{82}Se, ^{96}Zr, ^{116}Cd and ^{150}Nd. After 265 days of data collection from February 2003 until March 2004, no evidence for neutrinoless double beta decay (ββ0 ν) was found from \sim 7 kg of ^{100} Mo and \sim 1 kg of ^{82} Se. The corresponding lower limits for the half-lives are 3.5 \times 10^{23} years at 90% C.L for ^{100} Mo and 1.9 \times 10^{23} years for ^{82}Se. Limits for the effective Majorana neutrino mass are < \hspace{-0.5mm} m_ν \hspace{-0.5mm} > < 0.7-1.2 eV for ^{100} Mo and \linebreak < \hspace{-0.5mm} m_{ν\hspace{-0.5mm} > < 1.3-3.2 eV for ^{82}Se. Radon is the dominant background today and a Radon-free purification system will be in operation by the end of september 2004. The NEMO-3 expected sensitivity after 5 years of data is 0.2 eV.