Researcher profile

Arache Djannati-Ataï

Arache Djannati-Ataï contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2021arXiv

The DeLLight experiment to observe an optically-induced change of the vacuum index

Quantum electrodynamics predicts that the vacuum must behave as a nonlinear optical medium: the speed of light should be modified when the vacuum is stressed by intense electromagnetic fields. This optical phenomenon has not yet been observed. The DeLLight (Deflection of Light by Light) experiment aims to observe the optically-induced index change of vacuum, a nonlinear effect which has never been explored. The experiment is installed in the LASERIX facility at IJCLab, which delivers ultra-short intense laser pulses (2.5 J per pulse, each of 30 fs duration, with a 10 Hz repetition rate). The proposal is to measure the refraction of a probe laser pulse when crossing a transverse vacuum index gradient, produced by a very intense pump pulse. The refraction induces a transverse shift in the intensity profile of the probe, whose signal is amplified by a Sagnac interferometer. In this article, we describe the experimental method and setup, and present the complete theoretical calculations for the expected signal. With a minimum waist at focus of $5 \,μ$m (corresponding to a maximum intensity of $\sim 3 \times 10^{20}$ W/cm$^2$), and with the nonlinear vacuum index derived from QED, the expected refraction angle is 0.13 prad. First results of the interferometer prototype are presented. It is shown that an extinction factor $\mathcal{F} = 0.4 \times 10^{-5}$ (corresponding to a signal amplification factor of 250) and a spatial resolution $σ_y = 10$ nm are achievable. The expected signal is then about 15 pm, and could be observed at a 5-sigma confidence level with about one month of collected data.

preprint2011arXiv

A new analysis strategy for detection of faint gamma-ray sources with Imaging Atmospheric Cherenkov Telescopes

A new background rejection strategy for gamma-ray astrophysics with stereoscopic Imaging Atmospheric Cherenkov Telescopes (IACT), based on Monte Carlo (MC) simulations and real background data from the H.E.S.S. [High Energy Stereoscopic System, see [1].] experiment, is described. The analysis is based on a multivariate combination of both previously-known and newly-derived discriminant variables using the physical shower properties, as well as its multiple images, for a total of eight variables. Two of these new variables are defined thanks to a new energy evaluation procedure, which is also presented here. The method allows an enhanced sensitivity with the current generation of ground-based Cherenkov telescopes to be achieved, and at the same time its main features of rapidity and flexibility allow an easy generalization to any type of IACT. The robustness against Night Sky Background (NSB) variations of this approach is tested with MC simulated events. The overall consistency of the analysis chain has been checked by comparison of the real gamma-ray signal obtained from H.E.S.S. observations with MC simulations and through reconstruction of known source spectra. Finally, the performance has been evaluated by application to faint H.E.S.S. sources. The gain in sensitivity as compared to the best standard Hillas analysis ranges approximately from 1.2 to 1.8 depending on the source characteristics, which corresponds to an economy in observation time of a factor 1.4 to 3.2.