Researcher profile

Wataru Kokuyama

Wataru Kokuyama contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - Emerging
8works
0followers
7topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2022arXiv

Precise sinusoidal signal extraction from noisy waveform in vibration calibration

Precise extraction of sinusoidal vibration parameters is essential for the dynamic calibration of vibration sensors, such as accelerometers. However, several standard methods have not yet been optimized for large background noise. In this work, signal processing methods to extract small vibration signals from noisy data in the case of accelerometer calibration is discussed. The results show that spectral leakage degrades calibration accuracy. Three methods based on the use of a filter, window function, and numerical differentiation are investigated with theoretical calculations, simulations, and experiments. These methods can effectively reduce the contribution of the calibration system noise. The uncertainty of micro vibration calibration in the National Metrology Institute of Japan is reduced by two orders of magnitudes using the proposed methods. The theoretical analyses in this work can lay the foundation for the optimization of signal processing in vibration calibration, and can be applied to other dynamic calibration fields.

preprint2022arXiv

Primary accelerometer calibration with two-axis automatic positioning stage

In this study, we developed an automated, multipoint primary accelerometer calibration system using a two-axis positioning stage and a heterodyne laser interferometer. The proposed system offers low-cost, convenient, and automated multipoint accelerometer calibration, enabling less calibration lead time. The positioning stage also offers better positioning repeatability of 1 um, which is impossible through manual alignments. We measured the surface deformation of a laser reflection adaptor for a single-ended accelerometer by measuring more than 450 measurement positions. Visualizing the deformation of laser reflection surfaces facilitates understanding the effects of deformation or nonrectilinear motion, which are among the most significant uncertainty components in high-frequency accelerometer calibrations.

preprint2020arXiv

Phase meter based on zero-crossing counting of digitized signals

We developed a compact and easy-to-use phase meter based on a zero-crossing counting algorithm for digitized signals. Owing to the algorithm, the phase meter has low-noise and wide dynamic range. Low-noise differential phase measurements can be done for square waves (-204 $\mathrm{dBrad^{2}/Hz}$ for a 1-kHz, 1-$\mathrm{V_{p-p}}$ signal, 10 Hz-1 kHz offset, with cross-correlation) as well as sinusoidal waves, with a measurement error of $<1 \times 10^{-4}$ rad. We also demonstrated a direct phase measurement of an optical-beat note from a free-running laser over 10 decades (0.25 mHz-10 MHz) with a wide dynamic range of ~280 dB at 0.25 mHz. The phase meter can be an alternative for conventional phase meters and frequency counters in wide range of experiments.

preprint2016arXiv

Higher order test of Lorentz invariance with an optical ring cavity

We have developed an apparatus to search for the higher-order Lorentz violation in photons by measuring the resonant frequency difference between two counterpropagating directions of an asymmetric optical ring cavity. From the year-long data taken between 2012 and 2013, we found no evidence for the light speed anisotropy at the level of $δc/c \lesssim 10^{-15}$. Limits on the dipole components of the anisotropy are improved by more than an order of magnitude, and limits on the hexapole components are obtained for the first time. An overview of our apparatus and the data analysis in the framework of the spherical harmonics decomposition of anisotropy are presented. We also present the status of the recent upgrade of the apparatus.

preprint2016arXiv

Simple digital phase-measuring algorithm for low-noise heterodyne interferometry

We present a digital algorithm for measuring the phase difference between two sinusoidal signals that combines the modified fringe-counting method with two-sample zero crossing to enable sequential signal processing. This technique can be applied to a phase meter for measuring dynamic phase differences with high resolution, particularly for heterodyne interferometry. The floor noise obtained from a demonstration with an electrical apparatus is $5\times10^{-8} \mathrm{rad/\sqrt{Hz}}$ at frequencies above approximately 0.1 Hz. In addition, by applying this method to a commercial heterodyne interferometer, the floor-noise level is confirmed to be $7\times10^{-14} \mathrm{m/\sqrt{Hz}}$ from 4 kHz to 1 MHz. We also confirm the validity of the algorithm by comparing its results with those from a standard homodyne interferometer for measuring shock-motion peak acceleration greater than 5000 m/s^2 and a 10 mm stroke.

preprint2014arXiv

Search for a Stochastic Gravitational-wave Background using a pair of Torsion-bar Antennas

We have set a new upper limit on the stochastic gravitational wave background (SGWB) using two prototype Torsion-bar Antennas (TOBAs). TOBA is a low-frequency gravitational-wave detector with bar-shaped test masses rotated by the tidal force of gravitational waves. As a result of simultaneous 7-hour observations with TOBAs in Tokyo and Kyoto in Japan, our upper limit with a confidence level of 95% is $Ω_{\rm gw}h_0^2 < 1.9 \times 10^{17}$ at 0.035 - 0.830 Hz, where $h_{0}$ is the Hubble constant in units of 100 km/s/Mpc and $Ω_{\rm gw}$ is the gravitational wave energy density per logarithmic frequency interval in units of the closure density. We successfully updated the upper limit and extended the explored frequency band.

preprint2013arXiv

New Limit on Lorentz Violation Using a Double-Pass Optical Ring Cavity

A search for Lorentz violation in electrodynamics was performed by measuring the resonant frequency difference between two counterpropagating directions of an optical ring cavity. Our cavity contains a dielectric element, which makes our cavity sensitive to the violation. The laser frequency is stabilized to the counterclockwise resonance of the cavity, and the transmitted light is reflected back into the cavity for resonant frequency comparison with the clockwise resonance. This double-pass configuration enables a null experiment and gives high common mode rejection of environmental disturbances. We found no evidence for odd-parity anisotropy at the level of $δc /c \lesssim 10^{-14}$. Within the framework of the Standard Model Extension, our result put more than 5 times better limits on three odd-parity parameters $\tildeκ^{JK}_{o+}$ and a 12 times better limit on the scalar parameter $\tildeκ_{\tr}$ compared with the previous best limits.

preprint2011arXiv

Upper Limit on Gravitational Wave Backgrounds at 0.2 Hz with Torsion-bar Antenna

We present the first upper limit on gravitational wave (GW) backgrounds at an unexplored frequency of 0.2 Hz using a torsion-bar antenna (TOBA). A TOBA was proposed to search for low-frequency GWs. We have developed a small-scaled TOBA and successfully found Ωgw(f) < 4.3 \times 1017 at 0.2 Hz as demonstration of the TOBA&#39;s capabilities, where Ωgw (f) is the GW energy density per logarithmic frequency interval in units of the closure density. Our result is the first nonintegrated limit to bridge the gap between the LIGO band (around 100 Hz) and the Cassini band (10-6 - 10-4 Hz).