Researcher profile

Masaki Ando

Masaki Ando contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
9works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2022arXiv

Angular trapping of a linear-cavity mirror with an optical torsional spring

Optomechanical systems have been attracting intensive attention in various physical experiments. With an optomechanical system, the displacement of or the force acting on a mechanical oscillator can be precisely measured by utilizing optical interferometry. As a mechanical oscillator, a suspended mirror is often used in over milligram scale optomechanical systems. However, the tiny suspended mirror in a linear cavity can be unstable in its yaw rotational degree of freedom due to optical radiation pressure. This instability curbs the optical power that the cavity can accumulate in it, and imposes a limitation on the sensitivity. Here, we show that the optical radiation pressure can be used to trap the rotational motion of the suspended mirror without additional active feedback control when the $g$ factors of the cavity are negative and one mirror is much heavier than the other one. Furthermore, we demonstrate experimentally the validity of the trapping. We measured the rotational stiffness of a suspended tiny mirror with various intracavity power. The result indicates that the radiation pressure of the laser beam inside the cavity actually works as a positive restoring torque. Moreover, we discuss the feasibility of observing quantum radiation pressure fluctuation with our experimental setup as an application of our trapping configuration.

preprint2022arXiv

Wavefront Sensing with a Coupled Cavity for Torsion-Bar Antenna

Torsion-Bar Antenna (TOBA) is a ground-based gravitational wave detector using torsion pendulums. TOBA can detect intermediate-mass black hole binary mergers, gravitational wave stochastic background, and Newtonian noise, and is useful for earthquake early warning. A prototype detector Phase-III TOBA with 35 cm-scale pendulums is under development to demonstrate noise reduction. The target strain sensitivity is set to $1\times10^{-15}\,{/\sqrt{\rm Hz}}$ between 0.1 Hz--10 Hz. A new scheme of wavefront sensing with a coupled cavity was proposed to measure the pendulum rotation as low as $5\times10^{-16}\,{{\rm rad}/\sqrt{\rm Hz}}$ for Phase-III TOBA. In our method, an auxiliary cavity is used to enhance the first-order Hermite--Gaussian mode in a main cavity. Experimental demonstration is ongoing to confirm the feasibility of angular signal amplification and establish a method for locking a coupled cavity. We evaluated the performance of the coupled cavity and concluded that angular signal amplification would be feasible with this sensor. The coupled cavity was successfully locked to the resonance by the Pound--Drever--Hall technique with two modulation frequencies.

preprint2021arXiv

Dark matter Axion search with riNg Cavity Experiment DANCE: Design and development of auxiliary cavity for simultaneous resonance of linear polarizations

Axion-like particles (ALPs) are undiscovered pseudo-scalar particles that are candidates for ultralight dark matter. ALPs interact with photons slightly and cause the rotational oscillation of linearly polarized light. Dark matter Axion search with riNg Cavity Experiment (DANCE) searches for ALP dark matter by amplifying the rotational oscillation with a bow-tie ring cavity. Simultaneous resonance of linear polarizations is necessary to amplify both the carrier field and the ALP signal, and to achieve the design sensitivity. The sensitivity of the current prototype experiment DANCE Act-1 is less than expectation by around three orders of magnitude due to the resonant frequency difference between s- and p-polarization in the bow-tie ring cavity. In order to tune the resonant frequency difference, the method of introducing an auxiliary cavity was proposed. We designed an auxiliary cavity that can cancel out the resonant frequency difference and realize simultaneous resonance, considering optical loss. We also confirmed that the sensitivity of DANCE Act-1 with the auxiliary cavity can reach the original sensitivity.

preprint2021arXiv

First observation and analysis of DANCE: Dark matter Axion search with riNg Cavity Experiment

Dark matter Axion search with riNg Cavity Experiment (DANCE) was proposed to search for axion dark matter [Phys. Rev. Lett. 121, 161301 (2018)]. We aim to detect the rotation and oscillation of optical linear polarization caused by axion-photon coupling with a bow-tie cavity. DANCE can improve the sensitivity to axion-photon coupling constant $g_{a γ}$ for axion mass $m_a < 10^{-10}~\rm{eV}$ by several orders of magnitude compared to the best upper limits at present. A prototype experiment DANCE Act-1 is ongoing to demonstrate the feasibility of the method and to investigate technical noises. The optics was assembled and the performance of the cavity was evaluated. The first 12-day observation was successfully performed in May 2021. We reached $3 \times 10^{-6}~\rm{rad/\sqrt{Hz}}$ at $10~\rm{Hz}$ in the one-sided amplitude spectral density of the rotation angle of linear polarization.

preprint2021arXiv

Improvement of the target sensitivity in DECIGO by optimizing its parameters for quantum noise including the effect of diffraction loss

DECIGO is the future Japanese gravitational wave detector in outer space. We previously set the default design parameters to provide a good target sensitivity to detect the primordial gravitational waves (GWs). However, the updated upper limit of the primordial GWs by the Planck observations motivated us for further optimization of the target sensitivity. Previously, we had not considered optical diffraction loss due to the very long cavity length. In this paper, we optimize various DECIGO parameters by maximizing the signal-to-noise ratio (SNR), for the primordial GWs to quantum noise including the effects of diffraction loss. We evaluated the power spectrum density for one cluster in DECIGO utilizing the quantum noise of one differential Fabry-Perot interferometer. Then we calculated the SNR by correlating two clusters in the same position. We performed the optimization for two cases: the constant mirror-thickness case and the constant mirror-mass case. As a result, we obtained the SNR dependence on the mirror radius, which also determines various DECIGO parameters. This result is the first step toward optimizing the DECIGO design by considering the practical constraints on the mirror dimension and implementing other noise sources.

preprint2020arXiv

Atto-Nm Torque Sensing with a Macroscopic Optomechanical Torsion Pendulum

Precise measurements of the displacement of, and force acting on, a mechanical oscillator can be performed by coupling the oscillator to an optical cavity. Brownian thermal forces represent a fundamental limit to measurement sensitivity which impedes the ability to use precise force measurements as a tool of fundamental enquiry, particularly in the context of macroscopic quantum measurements and table-top gravitational experiments. A torsion pendulum with a low mechanical resonant frequency can be limited by very small thermal forces - from its suspensions - at frequencies above resonance. Here, we report torque sensing of a 10-mg torsion pendulum formed by a bar mirror, using two optical cavities on either edge. The rotational mode was measured by subtracting the two signals from the cavities, while intracavity radiation pressure forces were used to trap the torsional mode with a 1 kHz optical spring. The resulting torque sensitivity of 20 aNm/$\sqrt{\rm Hz}$ is a record for a milligram scale torsion pendulum. Such a massive optomechanical device featuring high sensitivity can shed light on macroscopic quantum mechanics and gravitational physics.

preprint2020arXiv

Current status of space gravitational wave antenna DECIGO and B-DECIGO

Deci-hertz Interferometer Gravitational Wave Observatory (DECIGO) is the future Japanese space mission with a frequency band of 0.1 Hz to 10 Hz. DECIGO aims at the detection of primordial gravitational waves, which could be produced during the inflationary period right after the birth of the universe. There are many other scientific objectives of DECIGO, including the direct measurement of the acceleration of the expansion of the universe, and reliable and accurate predictions of the timing and locations of neutron star/black hole binary coalescences. DECIGO consists of four clusters of observatories placed in the heliocentric orbit. Each cluster consists of three spacecraft, which form three Fabry-Perot Michelson interferometers with an arm length of 1,000 km. Three clusters of DECIGO will be placed far from each other, and the fourth cluster will be placed in the same position as one of the three clusters to obtain the correlation signals for the detection of the primordial gravitational waves. We plan to launch B-DECIGO, which is a scientific pathfinder of DECIGO, before DECIGO in the 2030s to demonstrate the technologies required for DECIGO, as well as to obtain fruitful scientific results to further expand the multi-messenger astronomy.

preprint2020arXiv

Prospects for improving the sensitivity of the cryogenic gravitational wave detector KAGRA

Upgrades to improve the sensitivity of gravitational wave detectors enable more frequent detections and more precise source parameter estimation. Unlike other advanced interferometric detectors such as Advanced LIGO and Advanced Virgo, KAGRA requires different approach for the upgrade since it is the only detector which employs cryogenic cooling of the test masses. In this paper, we describe possible KAGRA upgrades with technologies focusing on different detector bands, and compare the impacts on the detection of compact binary coalescences. We show that either fivefold improvement in the $100 M_{\odot}$--$100 M_{\odot}$ binary black hole range, a factor of 1.3 improvement in the binary neutron star range, or a factor of 1.7 improvement in the sky localization of binary neutron stars is well feasible with upgrades that do not require changes in the existing cryogenic or vacuum infrastructure. We also show that twofold broadband sensitivity improvement is possible by applying multiple upgrades to the detector.

preprint2019arXiv

DANCE: Dark matter Axion search with riNg Cavity Experiment

We have proposed a new approach to search for axion dark matter with an optical ring cavity [Phys. Rev. Lett. 121, 161301 (2018)]. The coupling of photons to axions or axion-like particles makes a modulated difference in the phase velocity between left- and right-handed photons. Our method is to measure this phase velocity difference with a ring cavity, by measuring the resonant frequency difference between two circular polarizations. Our estimation shows that the sensitivity to axion-photon coupling constant $g_{a γ}$ for axion mass $m \lesssim 10^{-10}$ eV can be improved by several orders of magnitude compared with the current best limits. In this paper, we present the principles of the Dark matter Axion search with riNg Cavity Experiment (DANCE) and the status of the prototype experiment, DANCE Act-1.