Researcher profile

Hideaki Nozato

Hideaki Nozato contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - Baseline
4works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

Precise sinusoidal signal extraction from noisy waveform in vibration calibration

Precise extraction of sinusoidal vibration parameters is essential for the dynamic calibration of vibration sensors, such as accelerometers. However, several standard methods have not yet been optimized for large background noise. In this work, signal processing methods to extract small vibration signals from noisy data in the case of accelerometer calibration is discussed. The results show that spectral leakage degrades calibration accuracy. Three methods based on the use of a filter, window function, and numerical differentiation are investigated with theoretical calculations, simulations, and experiments. These methods can effectively reduce the contribution of the calibration system noise. The uncertainty of micro vibration calibration in the National Metrology Institute of Japan is reduced by two orders of magnitudes using the proposed methods. The theoretical analyses in this work can lay the foundation for the optimization of signal processing in vibration calibration, and can be applied to other dynamic calibration fields.

preprint2022arXiv

Primary accelerometer calibration with two-axis automatic positioning stage

In this study, we developed an automated, multipoint primary accelerometer calibration system using a two-axis positioning stage and a heterodyne laser interferometer. The proposed system offers low-cost, convenient, and automated multipoint accelerometer calibration, enabling less calibration lead time. The positioning stage also offers better positioning repeatability of 1 um, which is impossible through manual alignments. We measured the surface deformation of a laser reflection adaptor for a single-ended accelerometer by measuring more than 450 measurement positions. Visualizing the deformation of laser reflection surfaces facilitates understanding the effects of deformation or nonrectilinear motion, which are among the most significant uncertainty components in high-frequency accelerometer calibrations.

preprint2020arXiv

Phase meter based on zero-crossing counting of digitized signals

We developed a compact and easy-to-use phase meter based on a zero-crossing counting algorithm for digitized signals. Owing to the algorithm, the phase meter has low-noise and wide dynamic range. Low-noise differential phase measurements can be done for square waves (-204 $\mathrm{dBrad^{2}/Hz}$ for a 1-kHz, 1-$\mathrm{V_{p-p}}$ signal, 10 Hz-1 kHz offset, with cross-correlation) as well as sinusoidal waves, with a measurement error of $<1 \times 10^{-4}$ rad. We also demonstrated a direct phase measurement of an optical-beat note from a free-running laser over 10 decades (0.25 mHz-10 MHz) with a wide dynamic range of ~280 dB at 0.25 mHz. The phase meter can be an alternative for conventional phase meters and frequency counters in wide range of experiments.

preprint2016arXiv

Simple digital phase-measuring algorithm for low-noise heterodyne interferometry

We present a digital algorithm for measuring the phase difference between two sinusoidal signals that combines the modified fringe-counting method with two-sample zero crossing to enable sequential signal processing. This technique can be applied to a phase meter for measuring dynamic phase differences with high resolution, particularly for heterodyne interferometry. The floor noise obtained from a demonstration with an electrical apparatus is $5\times10^{-8} \mathrm{rad/\sqrt{Hz}}$ at frequencies above approximately 0.1 Hz. In addition, by applying this method to a commercial heterodyne interferometer, the floor-noise level is confirmed to be $7\times10^{-14} \mathrm{m/\sqrt{Hz}}$ from 4 kHz to 1 MHz. We also confirm the validity of the algorithm by comparing its results with those from a standard homodyne interferometer for measuring shock-motion peak acceleration greater than 5000 m/s^2 and a 10 mm stroke.