Source author record

Vincent Giordano

Vincent Giordano appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

11works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

11 published item(s)

preprint2020arXiv

Magnetic sensitivity of the Microwave Cryogenic Sapphire Oscillator

The Cryogenic Sapphire Oscillator is today recognized for its unprecedented frequency stability, mainly coming from the exceptional physical properties of its resonator made in a high quality sapphire crystal. With these instruments, the fractional frequency measurement resolution, currently of the order of 1e-16, is such that it is possible to detect very small phenomena like residual resonator environmental sensitivities. Thus, we highlighted an unexpected magnetic sensitivity of the Cryogenic Sapphire Oscillator (CSO) at low magnetic field. The fractional frequency sensitivity has been preliminary evaluated to 1e-13/Gauss, making this phenomenon a potential cause of frequency stability limitation. In this paper we report the experimental data related to the magnetic sensitivity of the quasi-transverse magnetic Whispering Gallery (WGH) modes excited in sapphire crystals differing from their paramagnetic contaminants concentration. The magnetic behavior of the WGH modes does not follow the expected theory combining the Curie law and the Zeeman effect affecting the Electron Spin Resonance of the paramagnetic ions present in the crystal.

preprint2016arXiv

Characterization of Zero-Bias Microwave Diode Power Detectors at Cryogenic Temperature

We present the characterization of commercial tunnel diode low-level microwave power detectors at room and cryogenic temperatures. The sensitivity as well as the output voltage noise of the tunnel diodes are measured as functions of the applied microwave power, the signal frequency being 10 GHz. We highlight strong variations of the diode characteristics when the applied microwave power is higher than few microwatt. For a diode operating at ${4}$ K, the differential gain increases from ${1,000}$ V/W to about ${4,500}$ V/W when the power passes from ${-30}$ dBm to ${-20}$ dBm. The diode present a white noise floor equivalent to a NEP of ${0.8}$ pW/ ${\sqrt{\mathrm{Hz}}}$ and ${8}$ pW/${ \sqrt{\mathrm{Hz}}}$ at 4 K and 300 K respectively. Its flicker noise is equivalent to a relative amplitude noise power spectral density ${S_α(1~\mathrm{Hz})=-120}$~dB/Hz at ${4}$ K. Flicker noise is 10 dB higher at room temperature.

preprint2016arXiv

Compact Yb$^+$ optical atomic clock project: design principle and current status

We present the design of a compact optical clock based on the $^2S_{1/2} \rightarrow ^2D_{3/2}$ 435.5 nm transition in $^{171}$Yb$^+$. The ion trap will be based on a micro-fabricated circuit, with surface electrodes generating a trapping potential to localize a single Yb ion a few hundred $μ$m from the electrodes. We present our trap design as well as simulations of the resulting trapping pseudo-potential. We also present a compact, multi-channel wavelength meter that will permit the frequency stabilization of the cooling, repumping and clear-out lasers at 369.5 nm, 935.2 nm and 638.6 nm needed to cool the ion. We use this wavelength meter to characterize and stabilize the frequency of extended cavity diode lasers at 369.5 nm and 638.6 nm.

preprint2016arXiv

Cross-Spectrum PM Noise Measurements, Thermal Energy and Metamaterial Filters

Virtually all commercial instruments for the measurement of the oscillator PM noise make use of the Cross Spectrum method (arXiv:1004.5539 [physics.ins-det], 2010). High sensitivity is achieved by correlation and averaging on two equal channels which measure the same input, and reject the background of the instrument. We show that a systematic error is always present if the thermal energy of the input power splitter is not accounted for. Such error can result in noise under estimation up to a few dB in the lowest-noise quartz oscillators, and in a complete nonsense in the case of cryogenic oscillators. As another alarming fact, the presence of metamaterial components in the oscillator results in unpredictable behavior and large errors, even in well controlled experimental conditions. We observed a spread of 40 dB in the phase noise spectra of an oscillator, just replacing the output filter.

preprint2015arXiv

Characterization of the individual short-term frequency stability of Cryogenic Sapphire Oscillators at the 1e-16 level

We present the characterisation of three Cryogenic Sapphire Oscillators using the three-corner-hat method. Easily implemented with commercial components and instruments, this method reveals itself very useful to analyse the frequency stability limitations of these state-of-the-art ultra-stable oscillators. The best unit presents a fractional frequency stability better than 5e-16 at 1 s and below 2e-16 for integration times less than 5,000s.

preprint2015arXiv

Tests of Sapphire Crystals Produced with Different Growth Processes for Ultra-stable Microwave Oscillators

We present the characterization of 8-12 GHz whispering gallery mode resonators machined in high-quality sapphire crystals elaborated with different growth techniques. These microwave resonators are intended to constitute the reference frequency of ultra-stable Cryogenic Sapphire Oscillators. We conducted systematic tests near 4 K on these crystals to determine the unloaded Q-factor and the turnover temperature for whispering gallery modes in the 8-12 GHz frequency range. These characterizations show that high quality sapphire crystals elaborated with the Heat Exchange or the Kyropoulos growth technique are both suitable to meet a fractional frequency stability better than 1x10-15 for 1 s to 10.000 s integration times.

preprint2014arXiv

Influence of the ESR saturation on the power sensitivity of cryogenic sapphire resonators

Here, we study the paramagnetic ions behavior in presence of a strong microwave electromagnetic field sustained inside a cryogenic sapphire whispering gallery mode resonator. The high frequency measurement resolution that can be now achieved by comparing two CSOs permit for the first time to observe clearly the non-linearity of the resonator power sensitivity. These observations that in turn allow us to optimize the CSO operation, are well explained by the Electron Spin Resonance (ESR) saturation of the paramagnetic impurities contained in the sapphire crystal.

preprint2012arXiv

Controlling the Frequency-Temperature Sensitivity of a Cryogenic Sapphire Maser Frequency Standard by Manipulating Fe3+ Spins in the Sapphire Lattice

To create a stable signal from a cryogenic sapphire maser frequency standard, the frequency-temperature dependence of the supporting Whispering Gallery mode must be annulled. We report the ability to control this dependence by manipulating the paramagnetic susceptibility of Fe3+ ions in the sapphire lattice. We show that the maser signal depends on other Whispering Gallery modes tuned to the pump signal near 31 GHz, and the annulment point can be controlled to exist between 5 to 10 K depending on the Fe3+ ion concentration and the frequency of the pump. This level of control has not been achieved previously, and will allow improvements in the stability of such devices.

preprint2010arXiv

DC-powered Fe3+:sapphire Maser and its Sensitivity to Ultraviolet Light

The zero-field Fe3+:sapphire whispering-gallery-mode maser oscillator exhibits several alluring features: Its output is many orders of magnitude brighter than that of an active hydrogen maser and thus far less degraded by spontaneous-emission (Schawlow-Townes) and/or receiving-amplifier noise. Its oscillator loop is confined to a piece of mono-crystalline rock bolted into a metal can. Its quiet amplification combined with high resonator Q provide the ingredients for exceptionally low phase noise. We here concentrate on novelties addressing the fundamental conundrums and technical challenges that impede progress. (1) Roasting: The "mase-ability" of sapphire depends significantly on the chemical conditions under which it is grown and heat-treated. We provide some fresh details and nuances here. (2) Simplification: This paper obviates the need for a Ka-band synthesizer: it describes how a 31.3 GHz loop oscillator, operating on the preferred WG pump mode, incorporating Pound locking, was built from low-cost components. (3) "Dark Matter": A Siegman-level analysis of the experimental data determines the substitutional concentration of Fe3+ in HEMEX to be less than a part per billion prior to roasting and up to a few hundred ppb afterwards. Chemical assays, using different techniques (incl. glow discharge mass spectra spectroscopy and neutron activation analysis) consistently indicate, however, that HEMEX contains iron at concentrations of a few parts per million. Drawing from several forgotten-about/under-appreciated papers, this substantial discrepancy is addressed. (4) Excitons: Towards providing a new means of controlling the Fe3+:sapph. system, a cryogenic sapphire ring was illuminated, whilst masing, with UV light at wavelengths corresponding to known electronic and charge-transfer (thus valence-altering) transitions. Preliminary experiments are reported.

preprint2010arXiv

Unprecedented High Long Term Frequency Stability with a Macroscopic Resonator Oscillator

This article reports on the long-term frequency stabilty characterisation of a new type of cryogenic sapphire oscillator using an autonomous pulse-tube cryocooler as its cold source. This new design enables a relative frequency stability of better than 4.5e-15 over one day of integration. This represents to our knowledge the best long-term frequency stability ever obtained with a signal source based on a macroscopic resonator.

preprint2009arXiv

Creating traveling waves from standing waves from the gyrotropic paramagnetic properties of Fe$^{3+}$ ions in a high-Q whispering gallery mode sapphire resonator

We report observations of the gyrotropic change in magnetic susceptibility of the Fe$^{3+}$ electron paramagnetic resonance at 12.037GHz (between spin states $|1/2>$ and $|3/2>$) in sapphire with respect to applied magnetic field. Measurements were made by observing the response of the high-Q Whispering Gallery doublet (WGH$_{\pm17,0,0}$) in a Hemex sapphire resonator cooled to 5 K. The doublets initially existed as standing waves at zero field and were transformed to traveling waves due to the gyrotropic response.