Source author record

Stephan Falke

Stephan Falke appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

8works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2015arXiv

8E-17 fractional laser frequency instability with a long room-temperature cavity

We present a laser system based on a 48 cm long optical glass resonator. The large size requires a sophisticated thermal control and optimized mounting design. A self balancing mounting was essential to reliably reach sensitivities to acceleration of below $Δν/ ν$ < 2E-10 /g in all directions. Furthermore, fiber noise cancellations from a common reference point near the laser diode to the cavity mirror and to additional user points (Sr clock and frequency comb) are implemented. Through comparison to other cavity-stabilized lasers and to a strontium lattice clock an instability of below 1E-16 at averaging times from 1 s to 1000 s is revealed.

preprint2014arXiv

A strontium lattice clock with $3 \times 10^{-17}$ inaccuracy and its frequency

We have measured the absolute frequency of the optical lattice clock based on $^{87}$Sr at PTB with an uncertainty of $3.9\times 10^{-16}$ using two caesium fountain clocks. This is close to the accuracy of today's best realizations of the SI second. The absolute frequency of the 5s$^2$ $^1$S$_0$-5s5p $^3$P$_0$ transition in $^{87}$Sr is 429,228,004,229,873.13(17) Hz. Our result is in excellent agreement with recent measurements performed in different laboratories worldwide. We improved the total systematic uncertainty of our Sr frequency standard by a factor of five and reach $3\times 10^{-17}$, opening new prospects for frequency ratio measurements between optical clocks for fundamental research, geodesy, or optical clock evaluation.

preprint2014arXiv

Ultra-stable laser with average fractional frequency drift rate below $5\times10^{-19}/\mathrm{s}$

Cryogenic single-crystal optical cavities have the potential to provide highest dimensional stability. We have investigated the long-term performance of an ultra-stable laser system which is stabilized to a single-crystal silicon cavity operated at 124 K. Utilizing a frequency comb, the laser is compared to a hydrogen maser that is referenced to a primary caesium fountain standard and to the $^{87}\mathrm{Sr}$ optical lattice clock at PTB. With fractional frequency instabilities of $σ_y(τ)\leq2\times10^{-16}$ for averaging times of $τ=60\mathrm{~s}$ to $1000\mathrm{~s}$ and $σ_y(1 \mathrm{d})\leq 2\times10^{-15}$ the stability of this laser, without any aid from an atomic reference, surpasses the best microwave standards for short averaging times and is competitive with the best hydrogen masers for longer times of one day. The comparison of modeled thermal response of the cavity with measured data indicates a fractional frequency drift below $5\times 10^{-19}/\mathrm{s}$, which we do not expect to be a fundamental limit.

preprint2012arXiv

A compact and efficient strontium oven for laser-cooling experiments

Here we describe a compact and efficient strontium oven well suited for laser-cooling experiments. Novel design solutions allowed us to produce a collimated strontium atomic beam with a flux of 1.0\times10^13 s^-1 cm^-2 at the oven temperature of 450 °C, reached with an electrical power consumption of 36 W. The oven is based on a stainless-steel reservoir, filled with 6 g of metallic strontium, electrically heated in a vacuum environment by a tantalum wire threaded through an alumina multi-bore tube. The oven can be hosted in a standard DN40CF cube and has an estimated continuous operation lifetime of 10 years. This oven can be used for other alkali and alkaline earth metals with essentially no modifications.

preprint2012arXiv

Delivering pulsed and phase stable light to atoms of an optical clock

In optical clocks, transitions of ions or neutral atoms are interrogated using pulsed ultra-narrow laser fields. Systematic phase chirps of the laser or changes of the optical path length during the measurement cause a shift of the frequency seen by the interrogated atoms. While the stabilization of cw-optical links is now a well established technique even on long distances, phase stable links for pulsed light pose additional challanges and have not been demonstrated so far. In addition to possible temperature or pressure drift of the laboratory, which may lead to a Doppler shift by steadily changing the optical path length, the pulsing of the clock laser light calls for short settling times of stabilization locks. Our optical path length stabilization uses retro-reflected light from a mirror that is fixed with respect to the interrogated atoms and synthetic signals during the dark time. Length changes and frequency chirps are compensated for by the switching AOM. For our strontium optical lattice clock we have ensured that the shift introduced by the fiber link including the pulsing acousto optic modulator is below $2\cdot 10^{-17}$.

preprint2012arXiv

High accuracy correction of blackbody radiation shift in an optical lattice clock

We have determined the frequency shift that blackbody radiation is inducing on the $5s^2$ $^1$S$_0$ -- $5s5p$ $^3$P$_0$ clock transition in strontium. Previously its uncertainty limited the uncertainty of strontium lattice clocks to $1\times10^{-16}$. Now the uncertainty associated to the black body radiation shift correction translates to $5\times 10^{-18}$ relative frequency uncertainty at room temperature. Our evaluation is based on a measurement of the differential dc-polarizability of the two clock states and on a modeling of the dynamic contribution using this value and experimental data for other atomic properties.

preprint2012arXiv

Long range transport of ultra cold atoms in a far-detuned 1D optical lattice

We present a novel method to transport ultra cold atoms in a focused optical lattice over macroscopic distances of many Rayleigh ranges. With this method ultra cold atoms were transported over 5 cm in 250 ms without significant atom loss or heating. By translating the interference pattern together with the beam geometry the trap parameters are maintained over the full transport range. Thus, the presented method is well suited for tightly focused optical lattices that have sufficient trap depth only close to the focus. Tight focusing is usually required for far-detuned optical traps or traps that require high laser intensity for other reasons. The transport time is short and thus compatible with the operation of an optical lattice clock in which atoms are probed in a well designed environment spatially separated from the preparation and detection region.

preprint2010arXiv

Tackling the blackbody shift in a strontium optical lattice clock

A major obstacle for optical clocks is the frequency shift due to black body radiation. We discuss how one can tackle this problem in an optical lattice clock; in our case 87-Sr: firstly, by a measurement of the dc Stark shift of the clock transition and, secondly, by interrogating the atoms in a cryogenic environment. Both approaches rely on transporting ultracold atoms over several cm within a probe cycle. We evaluate this approach of mechanically moving the optical lattice and conclude that it is feasible to transport the atoms over 50 mm within 300 ms. With this transport a dc Stark shift measurement will allow to reduce the contribution of the blackbody radiation to the fractional uncertainty below 2 * 10^-17 at room temperature by improving the shift coefficient known only from atomic structure calculations up to now. We propose a cryogenic environment at 77 K that will reduce this contribution to few parts in 10^-18.