Researcher profile

Thomas Legero

Thomas Legero contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
12works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

12 published item(s)

preprint2020arXiv

Rubidium transitions as wavelength reference for astronomical Doppler spectrographs

Precise wavelength calibration is a critical issue for high-resolution spectroscopic observations. The ideal calibration source should be able to provide a very stable and dense grid of evenly distributed spectral lines of constant intensity. A new method which satisfies all mentioned conditions has been developed by our group. The approach is to actively measure the exact position of a single spectral line of a Fabry-Perot etalon with very high precision with a wavelength-tuneable laser and compare it to an extremely stable wavelength standard. The ideal choice of standard is the D2 absorption line of Rubidium, which has been used as an optical frequency standard for decades. With this technique, the problem of stable wavelength calibration of spectrographs becomes a problem of how reliably we can measure and anchor one etalon line to the Rb transition. In this work we present our self-built module for Rb saturated absorption spectroscopy and discuss its stability.

preprint2020arXiv

Thermal noise and mechanical loss of SiO$_2$/Ta$_2$O$_5$ optical coatings at cryogenic temperatures

Mechanical loss of dielectric mirror coatings sets fundamental limits for both gravitational wave detectors and cavity-stabilized optical local oscillators for atomic clocks. Two approaches are used to determine the mechanical loss: ringdown measurements of the coating quality factor and direct measurement of the coating thermal noise. Here we report a systematic study of the mirror thermal noise from room temperature to 4 K by operating reference cavities at these temperatures. The directly measured thermal noise is used to extract the corresponding mechanical loss for SiO$_2$/Ta$_2$O$_5$ coatings, which are compared with previously reported values.

preprint2015arXiv

8E-17 fractional laser frequency instability with a long room-temperature cavity

We present a laser system based on a 48 cm long optical glass resonator. The large size requires a sophisticated thermal control and optimized mounting design. A self balancing mounting was essential to reliably reach sensitivities to acceleration of below $Δν/ ν$ < 2E-10 /g in all directions. Furthermore, fiber noise cancellations from a common reference point near the laser diode to the cavity mirror and to additional user points (Sr clock and frequency comb) are implemented. Through comparison to other cavity-stabilized lasers and to a strontium lattice clock an instability of below 1E-16 at averaging times from 1 s to 1000 s is revealed.

preprint2014arXiv

A compact, robust, and transportable ultra-stable laser with a fractional frequency instability of $1\times10^{-15}$

We present a compact and robust transportable ultra-stable laser system with minimum fractional frequency instability of $1\times10^{-15}$ at integration times between 1 to 10 s. The system was conceived as a prototype of a subsystem of a microwave-optical local oscillator to be used on the satellite mission STE-QUEST (Space-Time Explorer and QUantum Equivalence Principle Space Test, http://sci.esa.int/ste-quest/). It was therefore designed to be compact, to sustain accelerations occurring during rocket launch, to exhibit low vibration sensitivity, and to reach a low frequency instability. Overall dimensions of the optical system are $40\textrm{ cm}\times20\textrm{ cm}\times30\textrm{ cm}$. The acceleration sensitivities of the optical frequency in the three directions were measured to be $1.7\times10^{-11}/g$, $8.0\times10^{-11}/g$, and $3.9\times10^{-10}/g$, and the absolute frequency instability was determined via a three-cornered hat measurement. The design is also appropriate and useful for terrestrial applications.

preprint2014arXiv

Ultra-stable laser with average fractional frequency drift rate below $5\times10^{-19}/\mathrm{s}$

Cryogenic single-crystal optical cavities have the potential to provide highest dimensional stability. We have investigated the long-term performance of an ultra-stable laser system which is stabilized to a single-crystal silicon cavity operated at 124 K. Utilizing a frequency comb, the laser is compared to a hydrogen maser that is referenced to a primary caesium fountain standard and to the $^{87}\mathrm{Sr}$ optical lattice clock at PTB. With fractional frequency instabilities of $σ_y(τ)\leq2\times10^{-16}$ for averaging times of $τ=60\mathrm{~s}$ to $1000\mathrm{~s}$ and $σ_y(1 \mathrm{d})\leq 2\times10^{-15}$ the stability of this laser, without any aid from an atomic reference, surpasses the best microwave standards for short averaging times and is competitive with the best hydrogen masers for longer times of one day. The comparison of modeled thermal response of the cavity with measured data indicates a fractional frequency drift below $5\times 10^{-19}/\mathrm{s}$, which we do not expect to be a fundamental limit.

preprint2013arXiv

Reducing the effect of thermal noise in optical cavities

Thermal noise in optical cavities imposes a severe limitation in the stability of the most advanced frequency standards at a level of a few 10^(-16) (s/t)^(1/2) for long averaging times t. In this paper we describe two schemes for reducing the effect of thermal noise in a reference cavity. In the first approach, we investigate the potential and limitations of operating the cavity close to instability, where the beam diameter on the mirrors becomes large. Our analysis shows that even a 10 cm short cavity can achieve a thermal noise limited fractional frequency instability in the low 10^(-16) regime. In the second approach, we increase the length of the optical cavity. We show that a 39.5 cm long cavity has the potential for a fractional frequency instability even below 10^(-16), while it seems feasible to achieve a reduced sensitivity of <10^(-10)/g for vibration-induced fractional length changes in all three directions.

preprint2011arXiv

Demonstration of a Transportable 1 Hz-Linewidth Laser

We present the setup and test of a transportable clock laser at 698 nm for a strontium lattice clock. A master-slave diode laser system is stabilized to a rigidly mounted optical reference cavity. The setup was transported by truck over 400 km from Braunschweig to Düsseldorf, where the cavity-stabilized laser was compared to a stationary clock laser for the interrogation of ytterbium (578 nm). Only minor realignments were necessary after the transport. The lasers were compared by a Ti:Sapphire frequency comb used as a transfer oscillator. The thus generated virtual beat showed a combined linewidth below 1 Hz (at 1156 nm). The transport back to Braunschweig did not degrade the laser performance, as was shown by interrogating the strontium clock transition.

preprint2011arXiv

Thermal noise in optical cavities revisited

Thermal noise of optical reference cavities sets a fundamental limit to the frequency instability of ultra-stable lasers. Using Levin&#39;s formulation of the fluctuation-dissipation theorem we correct the analytical estimate for the spacer contribution given by Numata et al.. For detailed analysis finite-element calculations of the thermal noise focusing on the spacer geometry, support structure and the usage of different materials have been carried out. We find that the increased dissipation close to the contact area between spacer and mirrors can contribute significantly to the thermal noise. From an estimate of the support structure contribution we give guidelines for a low-noise mounting of the cavity. For mixed-material cavities we show that the thermal expansion can be compensated without deteriorating the thermal noise.

preprint2010arXiv

Tuning the Thermal Expansion Properties of Optical Reference Cavities with Fused Silica Mirrors

We investigate the thermal expansion of low thermal noise Fabry-Perot cavities made of Low Thermal Expansion (LTE) glass spacers and Fused Silica (FS) mirrors. The different thermal expansion of mirror and spacer deforms the mirror. This deformation strongly contributes to the cavity&#39;s effective Coefficient of Thermal Expansion (CTE), decreasing the zero crossing temperature by about 20 K compared to an all-LTE glass cavity. Finite element simulations and CTE measurements show that LTE rings optically contacted to the back surface of the FS mirrors allow to tune the zero crossing temperature over a range of 30 K.

preprint2009arXiv

Phase- coherent comparison of two optical frequency standards over 146 km using a telecommunication fiber link

We have explored the performance of two &#34;dark fibers&#34; of a commercial telecommunication fiber link for a remote comparison of optical clocks. The two fibers, linking the Leibniz University of Hanover (LUH) with the Physi-kalisch-Technische Bundesanstalt (PTB) in Braunschweig, are connected in Hanover to form a total fiber length of 146 km. At PTB the performance of an optical frequency standard operating at 456 THz was imprinted to a cw trans-fer laser at 194 THz, and its frequency was transmitted over the fiber. In order to detect and compensate phase noise related to the optical fiber link we have built a low-noise optical fiber interferometer and investigated noise sources that affect the overall performance of the optical link. The frequency stability at the remote end has been measured using the clock laser of PTB&#39;s Yb+ frequency standard operating at 344 THz. We show that the frequency of a frequency-stabilized fiber laser can be transmitted over a total fiber length of 146 km with a relative frequency uncertainty below 1E-19, and short term frequency instability given by the fractional Allan deviation of sy(t)=3.3E-15/(t/s).

preprint2006arXiv

Time-resolved and state-selective detection of single freely falling atoms

We report on the detection of single, slowly moving Rubidium atoms using laser-induced fluorescence. The atoms move at 3 m/s while they are detected with a time resolution of 60 microseconds. The detection scheme employs a near-resonant laser beam that drives a cycling atomic transition, and a highly efficient mirror setup to focus a large fraction of the fluorescence photons to a photomultiplier tube. It counts on average 20 photons per atom.

preprint2002arXiv

Counter-Intuitive Vacuum-Stimulated Raman Scattering

Vacuum-stimulated Raman scattering in strongly coupled atom-cavity systems allows one to generate free-running single photon pulses on demand. Most properties of the emitted photons are well defined, provided spontaneous emission processes do not contribute. Therefore, electronic excitation of the atom must not occur, which is assured for a system adiabatically following a dark state during the photon-generation process. We experimentally investigate the conditions that must be met for adiabatic following in a time-of-flight driven system, with atoms passing through a cavity and a pump beam oriented transverse to the cavity axis. From our results, we infer the optimal intensity and relative pump-beam position with respect to the cavity axis.