Researcher profile

Tomonori Ikeda

Tomonori Ikeda contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
8works
0followers
8topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2022arXiv

Axion search with quantum nondemolition detection of magnons

The axion provides a solution for the strong CP problem and is one of the leading candidates for dark matter. This paper proposes an axion detection scheme based on quantum nondemolition detection of magnon, i.e., quanta of collective spin excitations in solid, which is expected to be excited by the axion-electron interaction predicted by the Dine-Fischer-Srednicki-Zhitnitsky (DFSZ) model. The prototype detector is composed of a ferrimagnetic sphere as an electronic spin target and a superconducting qubit. Both of these are embedded inside a microwave cavity, which leads to a coherent effective interaction between the uniform magnetostatic mode in the ferrimagnetic crystal and the qubit. An upper limit for the coupling constant between an axion and an electron is obtained as $g_{aee}<2.6\times10^{-6}$ at the 95% confidence level for the axion mass of $33.117$$μ$eV $<m_{a}<33.130$$μ$eV.

preprint2022arXiv

First observation of MeV gamma-ray universe with bijective imaging spectroscopy using the Electron-Tracking Compton Telescope aboard SMILE-2+

MeV gamma-rays provide a unique window for the direct measurement of line emissions from radioisotopes, but observations have made little significant progress after COMPTEL/{\it CGRO}. To observe celestial objects in this band, we are developing an electron-tracking Compton camera (ETCC), which realizes both bijective imaging spectroscopy and efficient background reduction gleaned from the recoil electron track information. The energy spectrum of the observation target can then be obtained by a simple ON-OFF method using a correctly defined point spread function on the celestial sphere. The performance of celestial object observations was validated on the second balloon SMILE-2+ installed with an ETCC having a gaseous electron tracker with a volume of 30$\times$30$\times$30 cm$^3$. Gamma-rays from the Crab nebula were detected with a significance of 4.0$σ$ in the energy range 0.15--2.1 MeV with a live time of 5.1 h, as expected before launching. Additionally, the light curve clarified an enhancement of gamma-ray events generated in the Galactic center region, indicating that a significant proportion of the final remaining events are cosmic gamma rays. Independently, the observed intensity and time variation were consistent with the pre-launch estimates except in the Galactic center region. The estimates were based on the total background of extragalactic diffuse, atmospheric, and instrumental gamma-rays after accounting for the variations in the atmospheric depth and rigidity during the level flight. The Crab results and light curve strongly support our understanding of both the detection sensitivity and the background in real observations. This work promises significant advances in MeV gamma-ray astronomy.

preprint2021arXiv

Development of Convolutional Neural Networks for an Electron-Tracking Compton Camera

Electron-tracking Compton camera, which is a complete Compton camera with tracking Compton scattering electron by a gas micro time projection chamber, is expected to open up MeV gamma-ray astronomy. The technical challenge for achieving several degrees of the point spread function is the precise determination of the electron-recoil direction and the scattering position from track images. We attempted to reconstruct these parameters using convolutional neural networks. Two network models were designed to predict the recoil direction and the scattering position. These models marked 41$~$degrees of the angular resolution and 2.1$~$mm of the position resolution for 75$~$keV electron simulation data in Argon-based gas at 2$~$atm pressure. In addition, the point spread function of ETCC was improved to 15$~$degrees from 22$~$degrees for experimental data of 662$~$keV gamma-ray source. These performances greatly surpassed that using the traditional analysis.

preprint2021arXiv

Direction-sensitive dark matter search with a low-background gaseous detector NEWAGE-0.3b&#39;&#39;

NEWAGE is a direction-sensitive dark matter search using a low-pressure gaseous time projection chamber. A low alpha-ray emission rate micro pixel chamber had been developed in order to reduce background for dark matter search. We conducted the dark matter search at the Kamioka Observatory in 2018. The total live time was 107.6 days corresponding to an exposure of 1.1 kg${\cdot}$days. Two events remained in the energy region of 50-60 keV which was consistent with 2.5 events of the expected background. A directional analysis was carried out and no significant forward-backward asymmetry derived from the WIMP-nucleus elastic scatterings was found. Thus a 90% confidence level upper limit on Spin-Dependent WIMP-proton cross section of 50 pb for a WIMP mass of 100 GeV/c2 was derived. This limit is the most stringent yet obtained from direction-sensitive dark matter search experiments.

preprint2020arXiv

Development of a low-$α$-emitting $μ$-PIC as a readout device for direction-sensitive dark matter detectors

Direction sensitivity could provide robust evidence for the direct detection of weakly interacting massive particles constituting dark matter. However, the sensitivity of this method remains low due to the radioactive backgrounds. The purpose of this study is to develop a low-background detector as a two-dimensional imaging device for a gaseous time projection chamber. In direction-sensitive dark matter experiments~(e.g. NEWAGE), $α$-rays emitted from the detector components often create substantial radioactive backgrounds. Based on the study of the background of NEWAGE, a new detector &#34;low-$α$ $μ$-PIC&#34; is developed. The produced $μ$-PIC performs well as a gas detector and the $α$-ray emission rate from the $μ$-PIC reduced by a factor of 100.

preprint2020arXiv

Discrimination of anisotropy in dark matter velocity distribution with directional detectors

Directional detection of dark matter has sensitivity for both recoil energy and direction of nuclear recoil. It opens the way to measure local velocity distribution of dark matter. In this paper, we study possibility to discriminate isotropic distribution and anisotropic one suggested by a N-body simulation with directional detector. Numerical simulation is performed for two cases according to the detectors, one corresponds to angular histogram and the other is energy-angular distribution of the signals. We reveal that the anisotropy of velocity distribution can be discriminated at 90% C.L. with chi-squared test if O($10^4$) signals are obtained.

preprint2020arXiv

First limits from a 3d-vector directional dark matter search with the NEWAGE-0.3b&#39; detector

The first directional dark matter search with three-dimensional tracking with head-tail sensitivity (3d-vector tracking analysis) was performed with a gaseous three-dimensional tarcking detector, or the NEWAGE-0.3b&#39; detector. The search was carried out from July 2013 to August 2017 (Run14 to Run18) at the Kamioka underground laboratory. The total livetime is 434.85 days corresponding to an exposure of 4.51 kg$\cdot$days. A 90 % confidence level upper limit on spin-dependent WIMP-proton cross section of $4.3 \times10^{2}$ pb for WIMPs with the mass of 150 GeV/$c^2$ is obtained.

preprint2020arXiv

Probing GHz Gravitational Waves with Graviton-magnon Resonance

A novel method for extending frequency frontier in gravitational wave observations is proposed. It is shown that gravitational waves can excite a magnon. Thus, gravitational waves can be probed by a graviton-magnon detector which measures resonance fluorescence of magnons. Searching for gravitational waves with a wave length $λ$ by using a ferromagnetic sample with a dimension $l$, the sensitivity of the graviton-magnon detector reaches spectral densities, around $5.4 \times 10^{-22} \times (\frac{l}{λ/2π})^{-2} \ [{\rm Hz}^{-1/2}]$ at 14 GHz and $8.6 \times 10^{-21} \times (\frac{l}{λ/2π})^{-2} \ [{\rm Hz}^{-1/2}]$ at 8.2 GHz, respectively.