Source author record

Toru Tanimori

Toru Tanimori appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

17works
8topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

17 published item(s)

preprint2022arXiv

First observation of MeV gamma-ray universe with bijective imaging spectroscopy using the Electron-Tracking Compton Telescope aboard SMILE-2+

MeV gamma-rays provide a unique window for the direct measurement of line emissions from radioisotopes, but observations have made little significant progress after COMPTEL/{\it CGRO}. To observe celestial objects in this band, we are developing an electron-tracking Compton camera (ETCC), which realizes both bijective imaging spectroscopy and efficient background reduction gleaned from the recoil electron track information. The energy spectrum of the observation target can then be obtained by a simple ON-OFF method using a correctly defined point spread function on the celestial sphere. The performance of celestial object observations was validated on the second balloon SMILE-2+ installed with an ETCC having a gaseous electron tracker with a volume of 30$\times$30$\times$30 cm$^3$. Gamma-rays from the Crab nebula were detected with a significance of 4.0$σ$ in the energy range 0.15--2.1 MeV with a live time of 5.1 h, as expected before launching. Additionally, the light curve clarified an enhancement of gamma-ray events generated in the Galactic center region, indicating that a significant proportion of the final remaining events are cosmic gamma rays. Independently, the observed intensity and time variation were consistent with the pre-launch estimates except in the Galactic center region. The estimates were based on the total background of extragalactic diffuse, atmospheric, and instrumental gamma-rays after accounting for the variations in the atmospheric depth and rigidity during the level flight. The Crab results and light curve strongly support our understanding of both the detection sensitivity and the background in real observations. This work promises significant advances in MeV gamma-ray astronomy.

preprint2022arXiv

Snowmass2021 Cosmic Frontier: The landscape of cosmic-ray and high-energy photon probes of particle dark matter

This white paper discusses the current landscape and prospects for experiments sensitive to particle dark matter processes producing photons and cosmic rays. Much of the gamma-ray sky remains unexplored on a level of sensitivity that would enable the discovery of a dark matter signal. Currently operating GeV-TeV observatories, such as Fermi-LAT, atmospheric Cherenkov telescopes, and water Cherenkov detector arrays continue to target several promising dark matter-rich environments within and beyond the Galaxy. Soon, several new experiments will continue to explore, with increased sensitivity, especially extended targets in the sky. This paper reviews the several near-term and longer-term plans for gamma-ray observatories, from MeV energies up to hundreds of TeV. Similarly, the X-ray sky has been and continues to be monitored by decade-old observatories. Upcoming telescopes will further bolster searches and allow new discovery space for lines from, e.g., sterile neutrinos and axion-photon conversion. Furthermore, this overview discusses currently operating cosmic-ray probes and the landscape of future experiments that will clarify existing persistent anomalies in cosmic radiation and spearhead possible new discoveries. Finally, the article closes with a discussion of necessary cross section measurements that need to be conducted at colliders to reduce substantial uncertainties in interpreting photon and cosmic-ray measurements in space.

preprint2021arXiv

Development of Convolutional Neural Networks for an Electron-Tracking Compton Camera

Electron-tracking Compton camera, which is a complete Compton camera with tracking Compton scattering electron by a gas micro time projection chamber, is expected to open up MeV gamma-ray astronomy. The technical challenge for achieving several degrees of the point spread function is the precise determination of the electron-recoil direction and the scattering position from track images. We attempted to reconstruct these parameters using convolutional neural networks. Two network models were designed to predict the recoil direction and the scattering position. These models marked 41$~$degrees of the angular resolution and 2.1$~$mm of the position resolution for 75$~$keV electron simulation data in Argon-based gas at 2$~$atm pressure. In addition, the point spread function of ETCC was improved to 15$~$degrees from 22$~$degrees for experimental data of 662$~$keV gamma-ray source. These performances greatly surpassed that using the traditional analysis.

preprint2021arXiv

Direction-sensitive dark matter search with a low-background gaseous detector NEWAGE-0.3b''

NEWAGE is a direction-sensitive dark matter search using a low-pressure gaseous time projection chamber. A low alpha-ray emission rate micro pixel chamber had been developed in order to reduce background for dark matter search. We conducted the dark matter search at the Kamioka Observatory in 2018. The total live time was 107.6 days corresponding to an exposure of 1.1 kg${\cdot}$days. Two events remained in the energy region of 50-60 keV which was consistent with 2.5 events of the expected background. A directional analysis was carried out and no significant forward-backward asymmetry derived from the WIMP-nucleus elastic scatterings was found. Thus a 90% confidence level upper limit on Spin-Dependent WIMP-proton cross section of 50 pb for a WIMP mass of 100 GeV/c2 was derived. This limit is the most stringent yet obtained from direction-sensitive dark matter search experiments.

preprint2020arXiv

First limits from a 3d-vector directional dark matter search with the NEWAGE-0.3b' detector

The first directional dark matter search with three-dimensional tracking with head-tail sensitivity (3d-vector tracking analysis) was performed with a gaseous three-dimensional tarcking detector, or the NEWAGE-0.3b' detector. The search was carried out from July 2013 to August 2017 (Run14 to Run18) at the Kamioka underground laboratory. The total livetime is 434.85 days corresponding to an exposure of 4.51 kg$\cdot$days. A 90 % confidence level upper limit on spin-dependent WIMP-proton cross section of $4.3 \times10^{2}$ pb for WIMPs with the mass of 150 GeV/$c^2$ is obtained.

preprint2020arXiv

MeV Gamma-ray imaging spectroscopic observation for Galactic Center and Cosmic Background MeV gammas by SMILE-2+ Balloon Experiment

Recently, there appears lots of papers on the possibility of light Dark Matter (DM) in MeV and sub-GeV scale. Until now, only INTEGRAL and COMPTEL provided experimental data of 511keV of galactic center, and two spectra of Galactic Diffuse MeV gammas (GDMG), and COMPTEL provided the Cosmic Background MeV gammas (CBMG) for wide sky for indirect detection of light DMs. However except 511keV, those spectra for diffuse gammas included large statistical and systematic errors in spite of 10 years observation, since both two instruments suffered from severe background radiation in space. In 2018 April, we (SMILE-project in Comic-ray Group of Kyoto University) have observed MeV gamma rays for whole southern sky by Electron Tracking Compton Camera (ETCC) using JAXA balloon at Australia during one-day. (SMILE2+ Project) By measuring all parameters of Compton scattering in every gamma, ETCC has achieved for the first time to obtain the complete direction of MeV gammas as same as optical telescopes, and also to distinguish signal gammas from huge background gammas in space clearly. In this observation, ETCC with a large Field of View of 3sr observed MeV gammas from 3/5 of all sky including galactic centre, a half disk, crab, and most of CBMG By reconstructing the Compton process, we successfully obtained pure comic gammas by reducing background by more 2 orders, which is clearly certificated by the clear enhancement of detected gamma flux with ~30% during galactic center passing through the Field of View, which is consistent with the ratio of CBMG and GDMG. Now 511keV gammas GDMG are preliminarily detected with ~5 and >10 sigma respectively around Galactic Centre. Also we have obtained near 105events of CBMG in with quite low background of only a few 10% in total CBMG events. Thus we obtained good data for both with high statistics and very low systematics even one day observation.

preprint2015arXiv

A performance study of an electron-tracking Compton camera with a compact system for environmental gamma-ray observation

An electron-tracking Compton camera (ETCC) is a detector that can determine the arrival direction and energy of incident sub-MeV/MeV gamma-ray events on an event-by-event basis. It is a hybrid detector consisting of a gaseous time projection chamber (TPC), that is the Compton-scattering target and the tracker of recoil electrons, and a position-sensitive scintillation camera that absorbs of the scattered gamma rays, to measure gamma rays in the environment from contaminated soil. To measure of environmental gamma rays from soil contaminated with radioactive cesium (Cs), we developed a portable battery-powered ETCC system with a compact readout circuit and data-acquisition system for the SMILE-II experiment. We checked the gamma-ray imaging ability and ETCC performance in the laboratory by using several gamma-ray point sources. The performance test indicates that the field of view (FoV) of the detector is about 1$\;$sr and that the detection efficiency and angular resolution for 662$\;$keV gamma rays from the center of the FoV is $(9.31 \pm 0.95) \times 10^{^-5}$ and $5.9^{\circ} \pm 0.6^{\circ}$, respectively. Furthermore, the ETCC can detect 0.15$\;μ\rm{Sv/h}$ from a $^{137}$Cs gamma-ray source with a significance of 5$σ$ in 13 min in the laboratory. In this paper, we report the specifications of the ETCC and the results of the performance tests. Furthermore, we discuss its potential use for environmental gamma-ray measurements.

preprint2015arXiv

New readout and data-acquisition system in an electron-tracking Compton camera for MeV gamma-ray astronomy (SMILE-II)

For MeV gamma-ray astronomy, we have developed an electron-tracking Compton camera (ETCC) as a MeV gamma-ray telescope capable of rejecting the radiation background and attaining the high sensitivity of near 1 mCrab in space. Our ETCC comprises a gaseous time-projection chamber (TPC) with a micro pattern gas detector for tracking recoil electrons and a position-sensitive scintillation camera for detecting scattered gamma rays. After the success of a first balloon experiment in 2006 with a small ETCC (using a 10$\times$10$\times$15 cm$^3$ TPC) for measuring diffuse cosmic and atmospheric sub-MeV gamma rays (Sub-MeV gamma-ray Imaging Loaded-on-balloon Experiment I; SMILE-I), a (30 cm)$^{3}$ medium-sized ETCC was developed to measure MeV gamma-ray spectra from celestial sources, such as the Crab Nebula, with single-day balloon flights (SMILE-II). To achieve this goal, a 100-times-larger detection area compared with that of SMILE-I is required without changing the weight or power consumption of the detector system. In addition, the event rate is also expected to dramatically increase during observation. Here, we describe both the concept and the performance of the new data-acquisition system with this (30 cm)$^{3}$ ETCC to manage 100 times more data while satisfying the severe restrictions regarding the weight and power consumption imposed by a balloon-borne observation. In particular, to improve the detection efficiency of the fine tracks in the TPC from $\sim$10\% to $\sim$100\%, we introduce a new data-handling algorithm in the TPC. Therefore, for efficient management of such large amounts of data, we developed a data-acquisition system with parallel data flow.

preprint2014arXiv

High-z gamma-ray bursts for unraveling the dark ages mission HiZ-GUNDAM

We are now investigating and studying a small satellite mission HiZ-GUNDAM for future observation of gamma-ray bursts (GRBs). The mission concept is to probe "the end of dark ages and the dawn of formation of astronomical objects", i.e. the physical condition of early universe beyond the redshift z > 7. We will consider two kinds of mission payloads, (1) wide field X-ray imaging detectors for GRB discovery, and (2) a near infrared telescope with 30 cm in diameter to select the high-z GRB candidates effectively. In this paper, we explain some requirements to promote the GRB cosmology based on the past observations, and also introduce the mission concept of HiZ-GUNDAM and basic development of X-ray imaging detectors.

preprint2013arXiv

Development of a Time-resolved Neutron Imaging Detector Based on the μPIC Micro-Pixel Chamber

We have developed a prototype time-resolved neutron imaging detector employing a micro-pattern gaseous detector known as the micro-pixel chamber (μPIC) coupled with a field-programmable-gate-array-based data acquisition system. Our detector system combines 100μm-level spatial and sub-μs time resolutions with a low gamma sensitivity of less than 10^-12 and high data rates, making it well suited for applications in neutron radiography at high-intensity, pulsed neutron sources. In the present paper, we introduce the detector system and present several test measurements performed at NOBORU (BL10), J-PARC to demonstrate the capabilities of our prototype. We also discuss future improvements to the spatial resolution and rate performance.

preprint2013arXiv

Spatial resolution of a μPIC-based neutron imaging detector

We present a detailed study of the spatial resolution of our time-resolved neutron imaging detector utilizing a new neutron position reconstruction method that improves both spatial resolution and event reconstruction efficiency. Our prototype detector system, employing a micro-pattern gaseous detector known as the micro-pixel chamber (μPIC) coupled with a field-programmable-gate-array-based data acquisition system, combines 100μm-level spatial and sub-μs time resolutions with excellent gamma rejection and high data rates, making it well suited for applications in neutron radiography at high-intensity, pulsed neutron sources. From data taken at the Materials and Life Science Experimental Facility within the Japan Proton Accelerator Research Complex (J-PARC), the spatial resolution was found to be approximately Gaussian with a sigma of 103.48 +/- 0.77 μm (after correcting for beam divergence). This is a significant improvement over that achievable with our previous reconstruction method (334 +/- 13 μm), and compares well with conventional neutron imaging detectors and with other high-rate detectors currently under development. Further, a detector simulation indicates that a spatial resolution of less than 60 μm may be possible with optimization of the gas characteristics and μPIC structure. We also present an example of imaging combined with neutron resonance absorption spectroscopy.

preprint2011arXiv

NEWAGE

NEWAGE is a direction-sensitive dark matter search experiment with a gaseous time-projection chamber. We improved the direction-sensitive dark matter limits by our underground measurement. After the first underground run, we replaced the detector components with radio-pure materials. We also studied the possibilities of head-tail recognition of nuclear tracks in the surface laboratory. For the future large volume detector, we are developing a pixel ASIC named QPIX. In this paper, these recent R&D activities are described.

preprint2011arXiv

Observation of Diffuse Cosmic and Atmospheric Gamma Rays at Balloon Altitudes with an Electron-tracking Compton Camera

We observed diffuse cosmic and atmospheric gamma rays at balloon altitudes with the Sub-MeV gamma-ray Imaging Loaded-on-balloon Experiment I (SMILE-I) as the first step toward a future all-sky survey with a high sensitivity. SMILE-I employed an electron-tracking Compton camera comprised of a gaseous electron tracker as a Compton-scattering target and a scintillation camera as an absorber. The balloon carrying the SMILE-I detector was launched from the Sanriku Balloon Center of the Institute of Space and Astronomical Science/Japan Space Exploration Agency on September 1, 2006, and the flight lasted for 6.8 hr, including level flight for 4.1 hr at an altitude of 32-35 km. During the level flight, we successfully detected 420 downward gamma rays between 100 keV and 1 MeV at zenith angles below 60 degrees. To obtain the flux of diffuse cosmic gamma rays, we first simulated their scattering in the atmosphere using Geant4, and for gamma rays detected at an atmospheric depth of 7.0 g cm-2, we found that 50% and 21% of the gamma rays at energies of 150 keV and 1 MeV, respectively, were scattered in the atmosphere prior to reaching the detector. Moreover, by using Geant4 simulations and the QinetiQ atmospheric radiation model, we estimated that the detected events consisted of diffuse cosmic and atmospheric gamma rays (79%), secondary photons produced in the instrument through the interaction between cosmic rays and materials surrounding the detector (19%), and other particles (2%). The obtained growth curve was comparable to Ling's model, and the fluxes of diffuse cosmic and atmospheric gamma rays were consistent with the results of previous experiments. The expected detection sensitivity of a future SMILE experiment measuring gamma rays between 150 keV and 20 MeV was estimated from our SMILE-I results and was found to be ten times better than that of other experiments at around 1 MeV.

preprint2010arXiv

First underground results with NEWAGE-0.3a direction-sensitive dark matter detector

A direction-sensitive dark matter search experiment at Kamioka underground laboratory with the NEWAGE-0.3a detector was performed. The NEWAGE- 0.3a detector is a gaseous micro-time-projection chamber filled with CF4 gas at 152 Torr. The fiducial volume and target mass are 20*25*31 cm3 and 0.0115 kg, respectively. With an exposure of 0.524 kgdays, improved spin-dependent weakly interacting massive particle (WIMP)-proton cross section limits by a direction-sensitive method were achieved including a new record of 5400 pb for 150 GeV/c2 WIMPs. We studied the remaining background and found that ambient gamma-rays contributed about one-fifth of the remaining background and radioactive contaminants inside the gas chamber contributed the rest.

preprint2003arXiv

Detecting the WIMP-wind via spin-dependent interactions

Revealing the nature of dark matter is one of the most interesting tasks in astrophysics. Measuring the distribution of recoil angles is said to be one of the most reliable methods to detect a positive signature of dark matter. We focused on measurements via spin-dependent interactions, and studied the feasibility with carbon tetrafluoride($\rm CF_4$) gas, while taking into account the performance of an existing three-dimensional tracking detector. We consequently found that it is highly possible to detect a positive signature of dark matter via spin-dependent interactions.

preprint2003arXiv

Performance of a micro-TPC for a time-resolved neutron PSD

We report on the performance of a micro-TPC with a micro pixel chamber($μ$-PIC) readout for a time-resolved neutron position-sensitive detector(PSD). Three-dimensional tracks and the Bragg curves of protons with energies of around 1 MeV were clearly detected by the micro-TPC. More than 95% of gamma-rays of 511 keV were found to be discriminated by simple analysis. Simulation studies showed that the total track length of proton and triton emitted from the $\rm {}^{3}He$(n,p(573 keV))$\rm {}^{3}H(191 keV)$ reaction is about 1.2 cm, and that both particles have large energy losses ($\rm > 200 keV/cm$) in 1 atm Ar+$\rm C_{2}H_{6}(10%)$+${}^{3}$He($< 1%$). These values suit the current performance of the micro-TPC, and we conclude that a time-resolved neutron PSD with spatial resolution of sub-millimeters shall be developed as an application of the micro-TPC.