Source author record

Kentaro Miuchi

Kentaro Miuchi appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

21works
11topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

21 published item(s)

preprint2022arXiv

Axion search with quantum nondemolition detection of magnons

The axion provides a solution for the strong CP problem and is one of the leading candidates for dark matter. This paper proposes an axion detection scheme based on quantum nondemolition detection of magnon, i.e., quanta of collective spin excitations in solid, which is expected to be excited by the axion-electron interaction predicted by the Dine-Fischer-Srednicki-Zhitnitsky (DFSZ) model. The prototype detector is composed of a ferrimagnetic sphere as an electronic spin target and a superconducting qubit. Both of these are embedded inside a microwave cavity, which leads to a coherent effective interaction between the uniform magnetostatic mode in the ferrimagnetic crystal and the qubit. An upper limit for the coupling constant between an axion and an electron is obtained as $g_{aee}<2.6\times10^{-6}$ at the 95% confidence level for the axion mass of $33.117$$μ$eV $<m_{a}<33.130$$μ$eV.

preprint2022arXiv

First observation of MeV gamma-ray universe with bijective imaging spectroscopy using the Electron-Tracking Compton Telescope aboard SMILE-2+

MeV gamma-rays provide a unique window for the direct measurement of line emissions from radioisotopes, but observations have made little significant progress after COMPTEL/{\it CGRO}. To observe celestial objects in this band, we are developing an electron-tracking Compton camera (ETCC), which realizes both bijective imaging spectroscopy and efficient background reduction gleaned from the recoil electron track information. The energy spectrum of the observation target can then be obtained by a simple ON-OFF method using a correctly defined point spread function on the celestial sphere. The performance of celestial object observations was validated on the second balloon SMILE-2+ installed with an ETCC having a gaseous electron tracker with a volume of 30$\times$30$\times$30 cm$^3$. Gamma-rays from the Crab nebula were detected with a significance of 4.0$σ$ in the energy range 0.15--2.1 MeV with a live time of 5.1 h, as expected before launching. Additionally, the light curve clarified an enhancement of gamma-ray events generated in the Galactic center region, indicating that a significant proportion of the final remaining events are cosmic gamma rays. Independently, the observed intensity and time variation were consistent with the pre-launch estimates except in the Galactic center region. The estimates were based on the total background of extragalactic diffuse, atmospheric, and instrumental gamma-rays after accounting for the variations in the atmospheric depth and rigidity during the level flight. The Crab results and light curve strongly support our understanding of both the detection sensitivity and the background in real observations. This work promises significant advances in MeV gamma-ray astronomy.

preprint2021arXiv

Direction-sensitive dark matter search with a low-background gaseous detector NEWAGE-0.3b''

NEWAGE is a direction-sensitive dark matter search using a low-pressure gaseous time projection chamber. A low alpha-ray emission rate micro pixel chamber had been developed in order to reduce background for dark matter search. We conducted the dark matter search at the Kamioka Observatory in 2018. The total live time was 107.6 days corresponding to an exposure of 1.1 kg${\cdot}$days. Two events remained in the energy region of 50-60 keV which was consistent with 2.5 events of the expected background. A directional analysis was carried out and no significant forward-backward asymmetry derived from the WIMP-nucleus elastic scatterings was found. Thus a 90% confidence level upper limit on Spin-Dependent WIMP-proton cross section of 50 pb for a WIMP mass of 100 GeV/c2 was derived. This limit is the most stringent yet obtained from direction-sensitive dark matter search experiments.

preprint2021arXiv

Scintillation light increase of carbontetrafluoride gas at low temperature

Scintillation detector is widely used for the particle detection in the field of particle physics. Particle detectors containing fluorine-19 ($^{19}\mathrm{F}$) are known to have advantages for Weakly Interacting Massive Particles (WIMPs) dark matter search, especially for spin-dependent interactions with WIMPs due to its spin structure. In this study, the scintillation properties of carbontetrafluoride ($\mathrm{CF_{4}}$) gas at low temperature was evaluated because its temperature dependence of light yield has not been measured. We evaluated the light yield by cooling the gas from room temperature (300K) to 263K. As a result, the light yield of $\mathrm{CF_{4}}$ was found to increase by $(41.0\pm4.0_{\rm stat.}\pm6.6_{\rm syst.})\%$ and the energy resolution was also found to improve at low temperature.

preprint2020arXiv

Detection capability of Migdal effect for argon and xenon nuclei with position sensitive gaseous detectors

Migdal effect is attracting interests because of the potential to enhance the sensitivities of direct dark matter searches to the low mass region. In spite of its great importance, the Migdal effect has not been experimentally observed yet. A realistic experimental approach towards the first observation of the Migdal effect in the neutron scattering was studied with Monte Carlo simulations. In this study, potential background rate was studied together with the event rate of the Migdal effect by a neutron source. It was found that a table-top sized $\sim (30\rm cm )^3$ position-sensitive gaseous detector filled with argon or xenon target gas can detect characteristic signatures of the Migdal effect with sufficient rates (O($10^2\sim10^3$) events/day). A simulation result of a simple experimental set-up showed two significant background sources, namely the intrinsic neutrons and the neutron induced gamma-rays. These background rates were found to be much higher than those of the Migdal effect in the neutron scattering. As a consequence of this study, it is concluded that the experimental observation of the Migdal effect in the neutron scattering can be realized with a good understanding and reduction of the background.

preprint2020arXiv

Development of a low-$α$-emitting $μ$-PIC as a readout device for direction-sensitive dark matter detectors

Direction sensitivity could provide robust evidence for the direct detection of weakly interacting massive particles constituting dark matter. However, the sensitivity of this method remains low due to the radioactive backgrounds. The purpose of this study is to develop a low-background detector as a two-dimensional imaging device for a gaseous time projection chamber. In direction-sensitive dark matter experiments~(e.g. NEWAGE), $α$-rays emitted from the detector components often create substantial radioactive backgrounds. Based on the study of the background of NEWAGE, a new detector "low-$α$ $μ$-PIC" is developed. The produced $μ$-PIC performs well as a gas detector and the $α$-ray emission rate from the $μ$-PIC reduced by a factor of 100.

preprint2020arXiv

Discrimination of anisotropy in dark matter velocity distribution with directional detectors

Directional detection of dark matter has sensitivity for both recoil energy and direction of nuclear recoil. It opens the way to measure local velocity distribution of dark matter. In this paper, we study possibility to discriminate isotropic distribution and anisotropic one suggested by a N-body simulation with directional detector. Numerical simulation is performed for two cases according to the detectors, one corresponds to angular histogram and the other is energy-angular distribution of the signals. We reveal that the anisotropy of velocity distribution can be discriminated at 90% C.L. with chi-squared test if O($10^4$) signals are obtained.

preprint2020arXiv

First limits from a 3d-vector directional dark matter search with the NEWAGE-0.3b' detector

The first directional dark matter search with three-dimensional tracking with head-tail sensitivity (3d-vector tracking analysis) was performed with a gaseous three-dimensional tarcking detector, or the NEWAGE-0.3b' detector. The search was carried out from July 2013 to August 2017 (Run14 to Run18) at the Kamioka underground laboratory. The total livetime is 434.85 days corresponding to an exposure of 4.51 kg$\cdot$days. A 90 % confidence level upper limit on spin-dependent WIMP-proton cross section of $4.3 \times10^{2}$ pb for WIMPs with the mass of 150 GeV/$c^2$ is obtained.

preprint2020arXiv

Probing GHz Gravitational Waves with Graviton-magnon Resonance

A novel method for extending frequency frontier in gravitational wave observations is proposed. It is shown that gravitational waves can excite a magnon. Thus, gravitational waves can be probed by a graviton-magnon detector which measures resonance fluorescence of magnons. Searching for gravitational waves with a wave length $λ$ by using a ferromagnetic sample with a dimension $l$, the sensitivity of the graviton-magnon detector reaches spectral densities, around $5.4 \times 10^{-22} \times (\frac{l}{λ/2π})^{-2} \ [{\rm Hz}^{-1/2}]$ at 14 GHz and $8.6 \times 10^{-21} \times (\frac{l}{λ/2π})^{-2} \ [{\rm Hz}^{-1/2}]$ at 8.2 GHz, respectively.

preprint2019arXiv

Measurement of ambient neutrons in an underground laboratory at Kamioka Observatory and future plan

Ambient neutrons are one of the most serious backgrounds for underground experiments in search of rare events. The ambient neutron flux in an underground laboratory of Kamioka Observatory was measured using a $\mathrm{^3He}$ proportional counter with various moderator setups. Since the detector response largely depends on the spectral shape, the energy spectra of the neutrons transported from the rock to the laboratory were estimated by Monte-Carlo simulations. The ratio of the thermal neutron flux to the total neutron flux was found to depend on the thermalizing efficiency of the rock. Thus, the ratio of the count rate without a moderator to that with a moderator was used to determine this parameter. Consequently, the most-likely neutron spectrum predicted by the simulations for the parameters determined by the experimental results was obtained. The result suggests an interesting spectral shape, which has not been indicated in previous studies. The total ambient neutron flux is $(23.5 \pm 0.7 \ \mathrm{_{stat.}} ^{+1.9}_{-2.1} \ \mathrm{_{sys.}}) \times 10^{-6}$ cm$^{-2}$ s$^{-1}$. In this paper, we explain our method of the result and discuss our future plan.

preprint2019arXiv

MPGD simulation in negative-ion gas for direction-sensitive dark matter searches

Negative-ion time projection chambers (NITPCs) provide the absolute z-position from the arrival-times' difference of several species of negative-ions. This is a strong background reduction method for rare event searches, such as direct dark mater searches. The characteristics of micro pattern gaseous detectors (MPGDs) in negative-ion gas were studied by both experiments and simulations to develop an NITPC for dark matter search experiments. An MPGD simulation method for the negative-ion gas with Garfield++, which has not yet been established, was developed. We present herein the MPGD simulation results in negative-ion gas, $\mathrm{SF_{6}}$ gas, together with the experimental results, such as gain, energy resolution, and signal creation from the MPGD for future NITPC optimization.

preprint2015arXiv

New readout and data-acquisition system in an electron-tracking Compton camera for MeV gamma-ray astronomy (SMILE-II)

For MeV gamma-ray astronomy, we have developed an electron-tracking Compton camera (ETCC) as a MeV gamma-ray telescope capable of rejecting the radiation background and attaining the high sensitivity of near 1 mCrab in space. Our ETCC comprises a gaseous time-projection chamber (TPC) with a micro pattern gas detector for tracking recoil electrons and a position-sensitive scintillation camera for detecting scattered gamma rays. After the success of a first balloon experiment in 2006 with a small ETCC (using a 10$\times$10$\times$15 cm$^3$ TPC) for measuring diffuse cosmic and atmospheric sub-MeV gamma rays (Sub-MeV gamma-ray Imaging Loaded-on-balloon Experiment I; SMILE-I), a (30 cm)$^{3}$ medium-sized ETCC was developed to measure MeV gamma-ray spectra from celestial sources, such as the Crab Nebula, with single-day balloon flights (SMILE-II). To achieve this goal, a 100-times-larger detection area compared with that of SMILE-I is required without changing the weight or power consumption of the detector system. In addition, the event rate is also expected to dramatically increase during observation. Here, we describe both the concept and the performance of the new data-acquisition system with this (30 cm)$^{3}$ ETCC to manage 100 times more data while satisfying the severe restrictions regarding the weight and power consumption imposed by a balloon-borne observation. In particular, to improve the detection efficiency of the fine tracks in the TPC from $\sim$10\% to $\sim$100\%, we introduce a new data-handling algorithm in the TPC. Therefore, for efficient management of such large amounts of data, we developed a data-acquisition system with parallel data flow.

preprint2013arXiv

Development of a Time-resolved Neutron Imaging Detector Based on the μPIC Micro-Pixel Chamber

We have developed a prototype time-resolved neutron imaging detector employing a micro-pattern gaseous detector known as the micro-pixel chamber (μPIC) coupled with a field-programmable-gate-array-based data acquisition system. Our detector system combines 100μm-level spatial and sub-μs time resolutions with a low gamma sensitivity of less than 10^-12 and high data rates, making it well suited for applications in neutron radiography at high-intensity, pulsed neutron sources. In the present paper, we introduce the detector system and present several test measurements performed at NOBORU (BL10), J-PARC to demonstrate the capabilities of our prototype. We also discuss future improvements to the spatial resolution and rate performance.

preprint2013arXiv

Spatial resolution of a μPIC-based neutron imaging detector

We present a detailed study of the spatial resolution of our time-resolved neutron imaging detector utilizing a new neutron position reconstruction method that improves both spatial resolution and event reconstruction efficiency. Our prototype detector system, employing a micro-pattern gaseous detector known as the micro-pixel chamber (μPIC) coupled with a field-programmable-gate-array-based data acquisition system, combines 100μm-level spatial and sub-μs time resolutions with excellent gamma rejection and high data rates, making it well suited for applications in neutron radiography at high-intensity, pulsed neutron sources. From data taken at the Materials and Life Science Experimental Facility within the Japan Proton Accelerator Research Complex (J-PARC), the spatial resolution was found to be approximately Gaussian with a sigma of 103.48 +/- 0.77 μm (after correcting for beam divergence). This is a significant improvement over that achievable with our previous reconstruction method (334 +/- 13 μm), and compares well with conventional neutron imaging detectors and with other high-rate detectors currently under development. Further, a detector simulation indicates that a spatial resolution of less than 60 μm may be possible with optimization of the gas characteristics and μPIC structure. We also present an example of imaging combined with neutron resonance absorption spectroscopy.

preprint2011arXiv

NEWAGE

NEWAGE is a direction-sensitive dark matter search experiment with a gaseous time-projection chamber. We improved the direction-sensitive dark matter limits by our underground measurement. After the first underground run, we replaced the detector components with radio-pure materials. We also studied the possibilities of head-tail recognition of nuclear tracks in the surface laboratory. For the future large volume detector, we are developing a pixel ASIC named QPIX. In this paper, these recent R&D activities are described.

preprint2011arXiv

Observation of Diffuse Cosmic and Atmospheric Gamma Rays at Balloon Altitudes with an Electron-tracking Compton Camera

We observed diffuse cosmic and atmospheric gamma rays at balloon altitudes with the Sub-MeV gamma-ray Imaging Loaded-on-balloon Experiment I (SMILE-I) as the first step toward a future all-sky survey with a high sensitivity. SMILE-I employed an electron-tracking Compton camera comprised of a gaseous electron tracker as a Compton-scattering target and a scintillation camera as an absorber. The balloon carrying the SMILE-I detector was launched from the Sanriku Balloon Center of the Institute of Space and Astronomical Science/Japan Space Exploration Agency on September 1, 2006, and the flight lasted for 6.8 hr, including level flight for 4.1 hr at an altitude of 32-35 km. During the level flight, we successfully detected 420 downward gamma rays between 100 keV and 1 MeV at zenith angles below 60 degrees. To obtain the flux of diffuse cosmic gamma rays, we first simulated their scattering in the atmosphere using Geant4, and for gamma rays detected at an atmospheric depth of 7.0 g cm-2, we found that 50% and 21% of the gamma rays at energies of 150 keV and 1 MeV, respectively, were scattered in the atmosphere prior to reaching the detector. Moreover, by using Geant4 simulations and the QinetiQ atmospheric radiation model, we estimated that the detected events consisted of diffuse cosmic and atmospheric gamma rays (79%), secondary photons produced in the instrument through the interaction between cosmic rays and materials surrounding the detector (19%), and other particles (2%). The obtained growth curve was comparable to Ling's model, and the fluxes of diffuse cosmic and atmospheric gamma rays were consistent with the results of previous experiments. The expected detection sensitivity of a future SMILE experiment measuring gamma rays between 150 keV and 20 MeV was estimated from our SMILE-I results and was found to be ten times better than that of other experiments at around 1 MeV.

preprint2010arXiv

First underground results with NEWAGE-0.3a direction-sensitive dark matter detector

A direction-sensitive dark matter search experiment at Kamioka underground laboratory with the NEWAGE-0.3a detector was performed. The NEWAGE- 0.3a detector is a gaseous micro-time-projection chamber filled with CF4 gas at 152 Torr. The fiducial volume and target mass are 20*25*31 cm3 and 0.0115 kg, respectively. With an exposure of 0.524 kgdays, improved spin-dependent weakly interacting massive particle (WIMP)-proton cross section limits by a direction-sensitive method were achieved including a new record of 5400 pb for 150 GeV/c2 WIMPs. We studied the remaining background and found that ambient gamma-rays contributed about one-fifth of the remaining background and radioactive contaminants inside the gas chamber contributed the rest.

preprint2003arXiv

Detecting the WIMP-wind via spin-dependent interactions

Revealing the nature of dark matter is one of the most interesting tasks in astrophysics. Measuring the distribution of recoil angles is said to be one of the most reliable methods to detect a positive signature of dark matter. We focused on measurements via spin-dependent interactions, and studied the feasibility with carbon tetrafluoride($\rm CF_4$) gas, while taking into account the performance of an existing three-dimensional tracking detector. We consequently found that it is highly possible to detect a positive signature of dark matter via spin-dependent interactions.

preprint2003arXiv

Performance of a micro-TPC for a time-resolved neutron PSD

We report on the performance of a micro-TPC with a micro pixel chamber($μ$-PIC) readout for a time-resolved neutron position-sensitive detector(PSD). Three-dimensional tracks and the Bragg curves of protons with energies of around 1 MeV were clearly detected by the micro-TPC. More than 95% of gamma-rays of 511 keV were found to be discriminated by simple analysis. Simulation studies showed that the total track length of proton and triton emitted from the $\rm {}^{3}He$(n,p(573 keV))$\rm {}^{3}H(191 keV)$ reaction is about 1.2 cm, and that both particles have large energy losses ($\rm > 200 keV/cm$) in 1 atm Ar+$\rm C_{2}H_{6}(10%)$+${}^{3}$He($< 1%$). These values suit the current performance of the micro-TPC, and we conclude that a time-resolved neutron PSD with spatial resolution of sub-millimeters shall be developed as an application of the micro-TPC.