Researcher profile

Alexander Nevsky

Alexander Nevsky contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
7works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2014arXiv

A compact, robust, and transportable ultra-stable laser with a fractional frequency instability of $1\times10^{-15}$

We present a compact and robust transportable ultra-stable laser system with minimum fractional frequency instability of $1\times10^{-15}$ at integration times between 1 to 10 s. The system was conceived as a prototype of a subsystem of a microwave-optical local oscillator to be used on the satellite mission STE-QUEST (Space-Time Explorer and QUantum Equivalence Principle Space Test, http://sci.esa.int/ste-quest/). It was therefore designed to be compact, to sustain accelerations occurring during rocket launch, to exhibit low vibration sensitivity, and to reach a low frequency instability. Overall dimensions of the optical system are $40\textrm{ cm}\times20\textrm{ cm}\times30\textrm{ cm}$. The acceleration sensitivities of the optical frequency in the three directions were measured to be $1.7\times10^{-11}/g$, $8.0\times10^{-11}/g$, and $3.9\times10^{-10}/g$, and the absolute frequency instability was determined via a three-cornered hat measurement. The design is also appropriate and useful for terrestrial applications.

preprint2014arXiv

A silicon single-crystal cryogenic optical resonator

We report on the demonstration and characterization of a silicon optical resonator for laser frequency stabilization, operating in the deep cryogenic regime at temperatures as low as 1.5 K. Robust operation was achieved, with absolute frequency drift less than 20 Hz over 1 hour. This stability allowed sensitive measurements of the resonator thermal expansion coefficient ($α$). We found $α=4.6\times10^{-13}$ ${\rm K^{-1}}$ at 1.6 K. At 16.8 K $α$ vanishes, with a derivative equal to $-6\times10^{-10}$ ${\rm K}^{-2}$. The temperature of the resonator was stabilized to a level below 10 $μ$K for averaging times longer than 20 s. The sensitivity of the resonator frequency to a variation of the laser power was also studied. The corresponding sensitivities and the expected Brownian noise indicate that this system should enable frequency stabilization of lasers at the low-$10^{-17}$ level.

preprint2013arXiv

Proton irradiation robustness of dielectric mirrors for high-finesse Fabry-Pérot resonators in the near-infrared spectral range

We demonstrate that a proton irradiation with fluences of $3.6\times10^{10}$/cm$^{2}$ at low energy ($<$ 36 MeV) and $1.46 \times 10^{10}$/cm$^{2}$ at high energy (40 MeV and 90 MeV combined) on the dielectric mirrors of Fabry-Pérot cavities with a finesse of about 700 000 causes less than 5% change in the finesse. Furthermore, no influence on the coupling efficiency to the cavities was observed, the efficiency being approximately 70%. The irradiation was carried out with a spectrum approximating the proton energy spectrum of a highly elliptic Earth orbit with duration of 5 years, proposed for the Space-Time Explorer and Quantum Equivalence Space Test (STE-QUEST) mission [\url{http://sci.esa.int/ste-quest/}].

preprint2013arXiv

Robust frequency stabilization of multiple spectroscopy lasers with large and tunable offset frequencies

We demonstrate a compact and robust device for simultaneous absolute frequency stabilization of three diode lasers whose carrier frequencies can be chosen freely relative to the reference. A rigid ULE multi-cavity block is employed, and, for each laser, the sideband locking technique is applied. Useful features of the system are a negligible lock error, computer control of frequency offset, wide range of frequency offset, simple construction, and robust operation. One concrete application is as a stabilization unit for the cooling and trapping lasers of a neutral atom lattice clock. The device significantly supports and improves the operation of the clock. The laser with the most stringent requirements imposed by this application is stabilized to a linewidth of 70 Hz, and a residual frequency drift less than 0.5 Hz/s. The carrier optical frequency can be tuned over 350 MHz while in lock.

preprint2012arXiv

Locking the frequency of lasers to an optical cavity at the $1.6 \times 10^{-17}$ relative instability level

We stabilized the frequencies of two independent Nd:YAG lasers to two adjacent longitudinal modes of a high-finesse Fabry-Pérot resonator and obtained a beat frequency instability of 6.3 mHz at an integration time of 40 s. Referred to a single laser, this is $1.6\times10^{-17}$ relative to the laser frequency, and $1.3\times10^{-6}$ relative to the full width at half maximum of the cavity resonance. The amplitude spectrum of the beat signal had a FWHM of 7.8 mHz. This stable frequency locking is of importance for next-generation optical clock interrogation lasers and fundamental physics tests.

preprint2011arXiv

Demonstration of a Transportable 1 Hz-Linewidth Laser

We present the setup and test of a transportable clock laser at 698 nm for a strontium lattice clock. A master-slave diode laser system is stabilized to a rigidly mounted optical reference cavity. The setup was transported by truck over 400 km from Braunschweig to Düsseldorf, where the cavity-stabilized laser was compared to a stationary clock laser for the interrogation of ytterbium (578 nm). Only minor realignments were necessary after the transport. The lasers were compared by a Ti:Sapphire frequency comb used as a transfer oscillator. The thus generated virtual beat showed a combined linewidth below 1 Hz (at 1156 nm). The transport back to Braunschweig did not degrade the laser performance, as was shown by interrogating the strontium clock transition.

preprint2011arXiv

Spectrally narrow, long-term stable optical frequency reference based on a Eu$^{3+}$:Y$_{2}$SiO$_{5}$ crystal at cryogenic temperature

Using an ultrastable continuous-wave laser at 580 nm we performed spectral hole burning of Eu$^{3+}$:Y$_{2}$SiO$_{5}$ at very high spectral resolution. Essential parameters determining the usefulness as a &#34;macroscopic&#34; frequency reference: linewidth, temperature sensitivity, long-term stability were characterized, using a H-maser stabilized frequency comb. Spectral holes with linewidth as low as 6 kHz were observed and the upper limit of the drift of the hole frequency was determined to be on the order of 5$\pm$3 mHz/s. We discuss necessary requirements for achieving ultra-high-stability in laser frequency stabilization to these spectral holes.