Source author record

Thomas Middelmann

Thomas Middelmann appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2015arXiv

Thermal expansion coefficient of single crystal silicon from 7 K to 293 K

We measured the absolute lengths of three single crystal silicon samples by means of an imaging Twyman-Green interferometer in the temperature range from 7 K to 293 K with uncertainties of about 1 nm. From these measurements we extract the coefficient of thermal expansion with uncertainties in the order of $1\times 10^{-9} {\rm /K}$. To access the functional dependence of the length on the temperature usually polynomials are fitted to the data. Instead we use a physically motivated model equation with 7 fit parameters for the whole temperature range. The coefficient of thermal expansion is obtained from the derivative of the best fit. The measurements conducted in 2012 and 2014 demonstrate a high reproducibility and the agreement of two independently produced samples supports single crystal silicon as reference material for thermal expansion. Although the results for all three samples agree with each other and with measurements performed at other institutes, they significantly differ from the recommended values for thermal expansion of crystalline silicon.

preprint2012arXiv

High accuracy correction of blackbody radiation shift in an optical lattice clock

We have determined the frequency shift that blackbody radiation is inducing on the $5s^2$ $^1$S$_0$ -- $5s5p$ $^3$P$_0$ clock transition in strontium. Previously its uncertainty limited the uncertainty of strontium lattice clocks to $1\times10^{-16}$. Now the uncertainty associated to the black body radiation shift correction translates to $5\times 10^{-18}$ relative frequency uncertainty at room temperature. Our evaluation is based on a measurement of the differential dc-polarizability of the two clock states and on a modeling of the dynamic contribution using this value and experimental data for other atomic properties.

preprint2012arXiv

Long range transport of ultra cold atoms in a far-detuned 1D optical lattice

We present a novel method to transport ultra cold atoms in a focused optical lattice over macroscopic distances of many Rayleigh ranges. With this method ultra cold atoms were transported over 5 cm in 250 ms without significant atom loss or heating. By translating the interference pattern together with the beam geometry the trap parameters are maintained over the full transport range. Thus, the presented method is well suited for tightly focused optical lattices that have sufficient trap depth only close to the focus. Tight focusing is usually required for far-detuned optical traps or traps that require high laser intensity for other reasons. The transport time is short and thus compatible with the operation of an optical lattice clock in which atoms are probed in a well designed environment spatially separated from the preparation and detection region.

preprint2010arXiv

Tackling the blackbody shift in a strontium optical lattice clock

A major obstacle for optical clocks is the frequency shift due to black body radiation. We discuss how one can tackle this problem in an optical lattice clock; in our case 87-Sr: firstly, by a measurement of the dc Stark shift of the clock transition and, secondly, by interrogating the atoms in a cryogenic environment. Both approaches rely on transporting ultracold atoms over several cm within a probe cycle. We evaluate this approach of mechanically moving the optical lattice and conclude that it is feasible to transport the atoms over 50 mm within 300 ms. With this transport a dc Stark shift measurement will allow to reduce the contribution of the blackbody radiation to the fractional uncertainty below 2 * 10^-17 at room temperature by improving the shift coefficient known only from atomic structure calculations up to now. We propose a cryogenic environment at 77 K that will reduce this contribution to few parts in 10^-18.