Source author record

Po T. Wang

Po T. Wang appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

7works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2020arXiv

Electromyogram (EMG) Removal by Adding Sources of EMG (ERASE) -- A novel ICA-based algorithm for removing myoelectric artifacts from EEG -- Part 1

Electroencephalographic (EEG) recordings are often contaminated by electromyographic (EMG) artifacts, especially when recording during movement. Existing methods to remove EMG artifacts include independent component analysis (ICA), and other high-order statistical methods. However, these methods can not effectively remove most of EMG artifacts. Here, we proposed a modified ICA model for EMG artifacts removal in the EEG, which is called EMG Removal by Adding Sources of EMG (ERASE). In this new approach, additional channels of real EMG from neck and head muscles (reference artifacts) were added as inputs to ICA in order to "force" the most power from EMG artifacts into a few independent components (ICs). The ICs containing EMG artifacts (the "artifact ICs") were identified and rejected using an automated procedure. Simulation results showed ERASE removed EMG artifacts from EEG significantly more effectively than conventional ICA. Subsequently, EEG was collected from 8 healthy participants while they moved their hands to test the realistic efficacy of this approach. Results showed that ERASE successfully removed EMG artifacts (on average, about 75% of EMG artifacts were removed when using real EMGs as reference artifacts) while preserving the expected EEG features related to movement. We also tested the ERASE procedure using simulated EMGs as reference artifacts (about 63% of EMG artifacts removed). Compared to conventional ICA, ERASE removed on average 26% more EMG artifacts from EEG. These results indicate that using additional real or simulated EMG sources can increase the effectiveness of ICA in removing EMG artifacts from EEG. Combined with automated artifact IC rejection, ERASE also minimizes potential user bias.

preprint2020arXiv

Electromyogram (EMG) Removal by Adding Sources of EMG (ERASE) -- A novel ICA-based algorithm for removing myoelectric artifacts from EEG -- Part 2

Extraction of the movement-related high-gamma (80 - 160 Hz) in electroencephalogram (EEG) from traumatic brain injury (TBI) patients who have had hemicraniectomies, remains challenging due to a confounding bandwidth overlap with surface electromyogram (EMG) artifacts related to facial and head movements. In part 1, we described an augmented independent component analysis (ICA) approach for removal of EMG artifacts from EEG, and referred to as EMG Reduction by Adding Sources of EMG (ERASE). Here, we tested ERASE on EEG recorded from six TBI patients with hemicraniectomies while they performed a thumb flexion task. ERASE removed a mean of 52 +/- 12% (mean +/- S.E.M) (maximum 73%) of EMG artifacts. In contrast, conventional ICA removed a mean of 27 +/- 19\% (mean +/- S.E.M) of EMG artifacts from EEG. In particular, high-gamma synchronization was significantly improved in the contralateral hand motor cortex area within the hemicraniectomy site after ERASE was applied. We computed fractal dimension (FD) of EEG high-gamma on each channel. We found relative FD of high-gamma over hemicraniectomy after applying ERASE were strongly correlated to the amplitude of finger flexion force. Results showed that significant correlation coefficients across the electrodes related to thumb flexion averaged 0.76, while the coefficients across the homologous electrodes in non-hemicraniectomy areas were nearly 0. Across all subjects, an average of 83% of electrodes significantly correlated with force was located in the hemicraniectomy areas after applying ERASE. After conventional ICA, only 19% of electrodes with significant correlations were located in the hemicraniectomy. These results indicated that the new approach isolated electrophysiological features during finger motor activation while selectively removing confounding EMG artifacts.

preprint2014arXiv

Electrocorticogram encoding of upper extremity movement trajectories

Electrocorticogram (ECoG)-based brain computer interfaces (BCI) can potentially control upper extremity prostheses to restore independent function to paralyzed individuals. However, current research is mostly restricted to the offline decoding of finger or 2D arm movement trajectories, and these results are modest. This study seeks to improve the fundamental understanding of the ECoG signal features underlying upper extremity movements to guide better BCI design. Subjects undergoing ECoG electrode implantation performed a series of elementary upper extremity movements in an intermittent flexion and extension manner. It was found that movement velocity, $\dotθ$, had a high positive (negative) correlation with the instantaneous power of the ECoG high-$γ$ band (80-160 Hz) during flexion (extension). Also, the correlation was low during idling epochs. Visual inspection of the ECoG high-$γ$ band revealed power bursts during flexion/extension events that have a waveform that strongly resembles the corresponding flexion/extension event as seen on $\dotθ$. These high-$γ$ bursts were present in all elementary movements, and were spatially distributed in a somatotopic fashion. Thus, it can be concluded that the high-$γ$ power of ECoG strongly encodes for movement trajectories, and can be used as an input feature in future BCIs.

preprint2013arXiv

Brain-Computer Interface Controlled Robotic Gait Orthosis

Reliance on wheelchairs after spinal cord injury (SCI) leads to many medical co-morbidities. Treatment of these conditions contributes to the majority of SCI health care costs. Restoring able-body-like ambulation after SCI may reduce the incidence of these conditions, and increase independence and quality of life. However, no biomedical solution exists that can reverse this lost neurological function, and hence novel methods are needed. Brain-computer interface (BCI) controlled lower extremity prosthesis may constitute one such novel approach. One subject with able-body and one with paraplegia due to SCI underwent electroencephalogram (EEG) recording while engaged in alternating epochs of idling and walking kinesthetic motor imagery (KMI). These data were analyzed to generate an EEG prediction model for online BCI operation. A commercial robotic gait orthosis (RoGO) system (treadmill suspended), was interfaced with the BCI computer. In an online test, the subjects were tasked to ambulate using the BCI-RoGO system when prompted by computerized cues. The performance of this system was assessed with cross-correlation analysis, and omission and false alarm rates. The offline accuracy of the EEG prediction model averaged 86.3%. The cross-correlation between instructional cues and BCI-RoGO walking epochs averaged 0.812 +/- 0.048 (p-value<10^-4). There were on average 0.8 false alarms per session and no omissions. This is the first time a person with parapegia due to SCI regained basic brain-controlled ambulation, thereby indicating that restoring brain-controlled ambulation is feasible. Future work will test this system in a population of individuals with SCI. If successful, this may justify future development of invasive BCI-controlled lower extremity prostheses. This system may also be applied to incomplete SCI to improve neurological outcomes beyond those of standard physiotherapy.

preprint2013arXiv

Pushing the Communication Speed Limit of a Noninvasive BCI Speller

Electroencephalogram (EEG) based brain-computer interfaces (BCI) may provide a means of communication for those affected by severe paralysis. However, the relatively low information transfer rates (ITR) of these systems, currently limited to 1 bit/sec, present a serious obstacle to their widespread adoption in both clinical and non-clinical applications. Here, we report on the development of a novel noninvasive BCI communication system that achieves ITRs that are severalfold higher than those previously reported with similar systems. Using only 8 EEG channels, 6 healthy subjects with little to no prior BCI experience selected characters from a virtual keyboard with sustained, error-free, online ITRs in excess of 3 bit/sec. By factoring in the time spent to notify the subjects of their selection, practical, error-free typing rates as high as 12.75 character/min were achieved, which allowed subjects to correctly type a 44-character sentence in less than 3.5 minutes. We hypothesize that ITRs can be further improved by optimizing the parameters of the interface, while practical typing rates can be significantly improved by shortening the selection notification time. These results provide compelling evidence that the ITR limit of noninvasive BCIs has not yet been reached and that further investigation into this matter is both justified and necessary.

preprint2012arXiv

Operation of a Brain-Computer Interface Walking Simulator by Users with Spinal Cord Injury

Background: Spinal cord injury (SCI) can leave the affected individuals unable to ambulate. Since there are no restorative treatments for SCI, novel approaches such as brain-controlled prostheses have been sought. Our recent studies show that a brain-computer interface (BCI) can be used to control ambulation within a virtual reality environment (VRE), suggesting that a BCI-controlled lower extremity prosthesis for ambulation may be feasible. However, the operability of our BCI has not been tested in a SCI population. Methods: Five subjects with paraplegia or tetraplegia due to SCI underwent a 10-min training session in which they alternated between kinesthetic motor imagery (KMI) of idling and walking while their electroencephalogram (EEG) were recorded. Subjects then performed a goal-oriented online task, where they utilized KMI to control the linear ambulation of an avatar and make 10 sequential stops at designated points within the VRE. Multiple online trials were performed over 5 experimental days. Results: Classification accuracy of idling and walking was estimated offline and ranged from 60.5% (p=0.0176) to 92.3% (p=1.36*10^-20) across subjects and days. In the online task, all subjects achieved purposeful control with an average performance of 7.4 +/- 2.3 successful stops in 273 +/- 51 sec (p<0.01). All subjects maintained purposeful control throughout the study, and their online performances improved over time. Conclusions: The results demonstrate that SCI subjects can purposefully operate a self-paced BCI walking simulator to complete a goal-oriented ambulation task. The operation of this BCI system requires short training, is intuitive, and robust against subject-to-subject and day-to-day neurophysiological variations. These findings indicate that BCI-controlled lower extremity prostheses for gait rehabilitation or restoration after SCI may be feasible in the future.

preprint2012arXiv

Self-paced brain-computer interface control of ambulation in a virtual reality environment

Objective: Spinal cord injury (SCI) often leaves affected individuals unable to ambulate. Electroencephalogramme (EEG) based brain-computer interface (BCI) controlled lower extremity prostheses may restore intuitive and able-body-like ambulation after SCI. To test its feasibility, the authors developed and tested a novel EEG-based, data-driven BCI system for intuitive and self-paced control of the ambulation of an avatar within a virtual reality environment (VRE). Approach: Eight able-bodied subjects and one with SCI underwent the following 10-min training session: subjects alternated between idling and walking kinaesthetic motor imageries (KMI) while their EEG were recorded and analysed to generate subject-specific decoding models. Subjects then performed a goal-oriented online task, repeated over 5 sessions, in which they utilised the KMI to control the linear ambulation of an avatar and make 10 sequential stops at designated points within the VRE. Main results: The average offline training performance across subjects was 77.2 +/- 9.5%, ranging from 64.3% (p = 0.00176) to 94.5% (p = 6.26*10^-23), with chance performance being 50%. The average online performance was 8.4 +/- 1.0 (out of 10) successful stops and 303 +/- 53 sec completion time (perfect = 211 sec). All subjects achieved performances significantly different than those of random walk (p < 0.05) in 44 of the 45 online sessions. Significance: By using a data-driven machine learning approach to decode users' KMI, this BCIVRE system enabled intuitive and purposeful self-paced control of ambulation after only a 10-minute training. The ability to achieve such BCI control with minimal training indicates that the implementation of future BCI-lower extremity prosthesis systems may be feasible.