Source author record

Charles Y. Liu

Charles Y. Liu appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

Transcranial photoacoustic computed tomography of human brain function

Herein we report the first in-human transcranial imaging of brain function using photoacoustic computed tomography. Functional responses to benchmark motor tasks were imaged on both the skull-less and the skull-intact hemispheres of a hemicraniectomy patient. The observed brain responses in these preliminary results demonstrate the potential of photoacoustic computed tomography for achieving transcranial functional imaging.

preprint2020arXiv

Electromyogram (EMG) Removal by Adding Sources of EMG (ERASE) -- A novel ICA-based algorithm for removing myoelectric artifacts from EEG -- Part 1

Electroencephalographic (EEG) recordings are often contaminated by electromyographic (EMG) artifacts, especially when recording during movement. Existing methods to remove EMG artifacts include independent component analysis (ICA), and other high-order statistical methods. However, these methods can not effectively remove most of EMG artifacts. Here, we proposed a modified ICA model for EMG artifacts removal in the EEG, which is called EMG Removal by Adding Sources of EMG (ERASE). In this new approach, additional channels of real EMG from neck and head muscles (reference artifacts) were added as inputs to ICA in order to "force" the most power from EMG artifacts into a few independent components (ICs). The ICs containing EMG artifacts (the "artifact ICs") were identified and rejected using an automated procedure. Simulation results showed ERASE removed EMG artifacts from EEG significantly more effectively than conventional ICA. Subsequently, EEG was collected from 8 healthy participants while they moved their hands to test the realistic efficacy of this approach. Results showed that ERASE successfully removed EMG artifacts (on average, about 75% of EMG artifacts were removed when using real EMGs as reference artifacts) while preserving the expected EEG features related to movement. We also tested the ERASE procedure using simulated EMGs as reference artifacts (about 63% of EMG artifacts removed). Compared to conventional ICA, ERASE removed on average 26% more EMG artifacts from EEG. These results indicate that using additional real or simulated EMG sources can increase the effectiveness of ICA in removing EMG artifacts from EEG. Combined with automated artifact IC rejection, ERASE also minimizes potential user bias.

preprint2020arXiv

Electromyogram (EMG) Removal by Adding Sources of EMG (ERASE) -- A novel ICA-based algorithm for removing myoelectric artifacts from EEG -- Part 2

Extraction of the movement-related high-gamma (80 - 160 Hz) in electroencephalogram (EEG) from traumatic brain injury (TBI) patients who have had hemicraniectomies, remains challenging due to a confounding bandwidth overlap with surface electromyogram (EMG) artifacts related to facial and head movements. In part 1, we described an augmented independent component analysis (ICA) approach for removal of EMG artifacts from EEG, and referred to as EMG Reduction by Adding Sources of EMG (ERASE). Here, we tested ERASE on EEG recorded from six TBI patients with hemicraniectomies while they performed a thumb flexion task. ERASE removed a mean of 52 +/- 12% (mean +/- S.E.M) (maximum 73%) of EMG artifacts. In contrast, conventional ICA removed a mean of 27 +/- 19\% (mean +/- S.E.M) of EMG artifacts from EEG. In particular, high-gamma synchronization was significantly improved in the contralateral hand motor cortex area within the hemicraniectomy site after ERASE was applied. We computed fractal dimension (FD) of EEG high-gamma on each channel. We found relative FD of high-gamma over hemicraniectomy after applying ERASE were strongly correlated to the amplitude of finger flexion force. Results showed that significant correlation coefficients across the electrodes related to thumb flexion averaged 0.76, while the coefficients across the homologous electrodes in non-hemicraniectomy areas were nearly 0. Across all subjects, an average of 83% of electrodes significantly correlated with force was located in the hemicraniectomy areas after applying ERASE. After conventional ICA, only 19% of electrodes with significant correlations were located in the hemicraniectomy. These results indicated that the new approach isolated electrophysiological features during finger motor activation while selectively removing confounding EMG artifacts.

preprint2014arXiv

Electrocorticogram encoding of upper extremity movement trajectories

Electrocorticogram (ECoG)-based brain computer interfaces (BCI) can potentially control upper extremity prostheses to restore independent function to paralyzed individuals. However, current research is mostly restricted to the offline decoding of finger or 2D arm movement trajectories, and these results are modest. This study seeks to improve the fundamental understanding of the ECoG signal features underlying upper extremity movements to guide better BCI design. Subjects undergoing ECoG electrode implantation performed a series of elementary upper extremity movements in an intermittent flexion and extension manner. It was found that movement velocity, $\dotθ$, had a high positive (negative) correlation with the instantaneous power of the ECoG high-$γ$ band (80-160 Hz) during flexion (extension). Also, the correlation was low during idling epochs. Visual inspection of the ECoG high-$γ$ band revealed power bursts during flexion/extension events that have a waveform that strongly resembles the corresponding flexion/extension event as seen on $\dotθ$. These high-$γ$ bursts were present in all elementary movements, and were spatially distributed in a somatotopic fashion. Thus, it can be concluded that the high-$γ$ power of ECoG strongly encodes for movement trajectories, and can be used as an input feature in future BCIs.