Source author record

Olivier Lopez

Olivier Lopez appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

28works
12topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

28 published item(s)

preprint2023arXiv

Parametric insurance for extreme risks: the challenge of properly covering severe claims

Parametric insurance has emerged as a practical way to cover risks that may be difficult to assess. By introducing a parameter that triggers compensation and allows the insurer to determine a payment without estimating the actual loss, these products simplify the compensation process, and provide easily traceable indicators to perform risk management. On the other hand, this parameter may sometimes deviate from its intended purpose, and may not always accurately represent the basic risk. In this paper, we provide theoretical results that investigate the behavior of parametric insurance products when faced with large claims. In particular, these results measure the difference between the actual loss and the parameter in a generic situation, with a particular focus on heavy-tailed losses. These results may help to anticipate, in presence of heavy-tail phenomena, how parametric products should be supplemented by additional compensation mechanisms in case of large claims. Simulation studies, that complement the analysis, show the importance of nonlinear dependence measures in providing a good protection over the whole distribution.

preprint2022arXiv

Experimental study of the $^{40,48}$Ca+ $^{40,48}$Ca reactions at 35 MeV/nucleon

In this article we investigate $^{40,48}$Ca+$^{40,48}$Ca peripheral and semi-peripheral reactions at 35 MeV/nucleon. Data were obtained using the unique coupling of the VAMOS high acceptance spectrometer and the INDRA charged particle multidetector.The spectrometer allowed high resolution measurement of charge, mass and velocity of the cold projectile-like fragment (PLF), while the INDRA detector recorded coincident charged particles with nearly $4π$ acceptance.The measured isotopic composition of the PLF identified in VAMOS and the average light charged particle (LCP) multiplicities are promising observables to study the isospin diffusion.The detection of the PLF in coincidence with LCP allows the reconstruction of the mass, charge and excitation energy of the associated initial quasi-projectile nuclei (QP), as well as the extraction of apparent temperatures.We investigate the suitability of the isoscaling method with the PLF and the experimental reconstructed QP.The extracted $α$ and $Δ$ isoscaling parameters present a dependence on the considered system combination that could justify their use as a surrogate for isospin asymmetry in isospin transport studies.The reconstruction of the QP allows to observe an evolution of the $α/Δ$ with the size of the QP, the latter being consistent with a strong surface contribution to the symmetry energy term in finite nuclei. This leads to the conclusion that the reconstruction of the primary source is mandatory for the study of the symmetry energy term based on the isoscaling method for such reactions.

preprint2022arXiv

Experimental study of the isospin transport with 40,48 Ca+ 40,48 Ca reactions at 35 MeV/nucleon

We investigate the isospin transport with 40,48 Ca+ 40,48 Ca reactions at 35 MeV/nucleon, measured with the coupling of the VAMOS high acceptance spectrometer and the INDRA charged particle multidetector. Using the quasi-projectile remnant measured with VAMOS and carefully selected light-charged-particles measured in coincidence with INDRA, a reconstruction method is applied to estimate the excited quasi-projectile (QP) on an event-by-event basis. The isospin diffusion is investigated using the isospin transport ratio with the asymmetry $δ$ = (N -- Z)/A of the projectile as an isospin-sensitive observable and the total transverse energy of Z $\le$ 2 nuclei for experimental centrality sorting. The experimental isospin transport ratios present, for both the reconstructed QP and its remnant, a clear evolution towards isospin equilibration with increasing dissipation of the collision while the full equilibration is not reached. A smoother evolution with less discrepancies between the two mixed systems in the case of the reconstructed QP is also observed. The isospin migration is investigated using the neutron-to-proton ratio of the light-charged-clusters and the velocity of the QP remnant as a sorting parameter. More particularly, we focused on an angular region centered around the mid-rapidity of the reaction so as to characterize the low-density neck emissions. A systematic neutron-enrichment is observed and interpreted as a consequence of isospin migration, more particularly for the symmetric systems which present no isospin gradient between the projectile and the target. We also noticed that the ^{2}H and ^{4}He particles exhibit very close multiplicities independently of the sorting variable for the symmetric systems.

preprint2022arXiv

Limitations due to residual interference in a fiber-based optical frequency reference at 1.55 $μ$m

We present an experimental investigation of the stability limits specific to optical frequency standards using a fiber-optic architecture and semiconductor lasers. A compact setup composed of a semiconductor laser frequency-locked onto an acetylene transition detected in saturated absorption has been implemented using only fiber-optic components. Fiber optic technology allows compact and reliable solutions for various applications. However, for high sensitivity and stability applications such as metrology, residual reflections induced by optical index inhomogeneities in connectors and fiber-coupled components leading to spurious interference significantly limit performance. We have examined the origin of the interference fringes superimposed on the detected signal and the limitations they cause to the frequency stability of the reference. The effects of temperature and beam power fluctuations are also examined. Our results show that the frequency stability is limited in the 10-13 range by the effect of interference fringes due to use of fiber components.

preprint2020arXiv

Improved method for the experimental determination of in-medium effects from heavy-ion collisions

The equation of state with light clusters for nuclear and stellar matter is determined using chemical equilibrium constants evaluated from the analysis of the recently published (Xe$+$Sn) heavy ion data, corresponding to three reactions with different isotopic contents of the emission source. The measured multiplicities are used to extract the thermodynamic properties, and an in-medium correction to the ideal gas internal partition function of the clusters is included in the analysis. This in-medium correction and its respective uncertainty are calculated via a Bayesian analysis, with the unique hypothesis that the different nuclear species in a given sample must correspond to a unique common value for the density of the expanding source. Different parameter sets for the correction are tested, and the effect of the radius of the clusters on the thermodynamics and on the chemical equilibrium constants is also addressed. It is shown that the equilibrium constants obtained are almost independent of the isospin content of the analysed systems. Finally, a comparison with a relativistic mean field model proves that data are consistent with a universal in-medium correction of the scalar $σ$-meson coupling for nucleons bound in clusters. The obtained value, $g_s/g_s^0 = 0.92 \pm 0.02$, is larger than that obtained in a previous study not including in-medium effects in the data analysis. This result implies a smaller effect on the binding energy of the clusters and, as a consequence, larger melting densities, and an increased cluster contribution in supernova matter.

preprint2020arXiv

Industrial applications of digital rock technology

This article provides an overview of the current state of digital rock technology, with emphasis on industrial applications. We show how imaging and image analysis can be applied for rock typing and modeling of end-point saturations. Different methods to obtain a digital model of the pore space from pore scale images are presented, and the strengths and weaknesses of the different methods are discussed. We also show how imaging bridges the different subjects of geology, petrophysics and reservoir simulations, by being a common denominator for results in all these subjects. Network modeling is compared to direct simulations on grid models, and their respective strengths are discussed. Finally we present an example of digital rock technology applied to a sandstone oil reservoir. Results from digital rock modeling are compared to results from traditional laboratory experiments. We highlight the mutual benefits from conducting both traditional experiments and digital rock modeling.

preprint2020arXiv

Low-density in-medium effects on light clusters from heavy-ion data

The modification of the ground state properties of light atomic nuclei in the nuclear and stellar medium is addressed, using chemical equilibrium constants evaluated from a new analysis of the intermediate energy heavy-ion (Xe$+$Sn) collision data measured by the INDRA collaboration. Three different reactions are considered, mainly differing by the isotopic content of the emission source. The thermodynamic conditions of the data samples are extracted from the measured multiplicities allowing for a parametrization of the in-medium modification, determined with the single hypothesis that the different nuclear species in a given sample correspond to a unique common value for the density of the expanding source. We show that this correction, which was not considered in previous analyses of chemical constants from heavy ion collisions, is necessary, since the observables of the analyzed systems show strong deviations from the expected results for an ideal gas of free clusters. This data set is further compared to a relativistic mean-field model, and seen to be reasonably compatible with a universal correction of the attractive $σ$-meson coupling.

preprint2016arXiv

Ultra-stable optical frequency dissemination on a multi-access fibre network

We report the dissemination of an ultrastable optical frequency signal to two distant users simultaneously using a branching network. The ultrastable signal is extracted along a main fibre link; it is optically tracked with a narrow-linewidth laser diode, which light is injected in a secondary link. The propagation noise of both links is actively compensated. We implement this scheme with two links of 50-km fibre spools, the extraction being setup at the mid-point of the main link. We show that the extracted signal at the end of the secondary link exhibits fractional frequency instability of 1.4x10-15 at 1-s measurement time, almost equal to the 1.3x10-15 instability of the main link output end. The long-term instabilities are also very similar, at a level of 3-5x10-20 at 3x104-s integration time. We also show that the setting up of this extraction device, or a simpler one, at the main link input, can test the proper functioning of the noise rejection on this main link. This work is a significant step towards a robust and flexible ultra-stable network for multi-users dissemination.

preprint2015arXiv

Cascaded optical fiber link using the Internet network for remote clocks comparison

We report a cascaded optical link of 1100 km for ultra-stable frequency distribution over an Internet fiber network. The link is composed of four spans for which the propagation noise is actively compensated. The robustness and the performance of the link are ensured by five fully automated optoelectronic stations, two of them at the link ends, and three deployed on the field and connecting the spans. This device coherently regenerates the optical signal with the heterodyne optical phase locking of a low-noise laser diode. Optical detection of the beat-note signals for the laser lock and the link noise compensation are obtained with stable and low-noise fibered optical interferometer. We show 3.5 days of continuous operation of the noise-compensated 4-span cascaded link leading to fractional frequency instability of 4x10-16 at 1-s measurement time and 1x10-19 at 2000 s. This cascaded link was extended to 1480-km with the same performance. This work is a significant step towards a sustainable wide area ultra-stable optical frequency distribution and comparison network at a very high level of performance.

preprint2015arXiv

Frequency and time transfer for metrology and beyond using telecommunication network fibres

The distribution and the comparison of an ultra-stable optical frequency and accurate time using optical fibres have been greatly improved in the last ten years. The frequency stability and accuracy of optical links surpass well-established methods using the global navigation satellite system and geostationary satellites. In this paper, we present a review of the methods and the results obtained. We show that public telecommunication network carrying Internet data can be used to compare and distribute ultra-stable metrological signals over long distances. This novel technique paves the way for the deployment of a national and continental ultra-stable metrological optical network.

preprint2014arXiv

A widely tunable 10-$μ$m quantum cascade laser phase-locked to a state-of-the-art mid-infrared reference for precision molecular spectroscopy

We report the coherent phase-locking of a quantum cascade laser (QCL) at 10-$μ$m to the secondary frequency standard of this spectral region, a CO2 laser stabilized on a saturated absorption line of OsO4. The stability and accuracy of the standard are transferred to the QCL resulting in a line width of the order of 10 Hz, and leading to our knowledge to the narrowest QCL to date. The locked QCL is then used to perform absorption spectroscopy spanning 6 GHz of NH3 and methyltrioxorhenium, two species of interest for applications in precision measurements.

preprint2014arXiv

In-line extraction of an ultra-stable frequency signal over an optical fiber link

We demonstrate in-line extraction of an ultra-stable frequency signal over an optical link of 92-km of installed telecommunication fibers, following the proposition of G. Grosche in 2010. We show that the residual frequency noise at the extraction end is noticeably below that at the main link output when the extraction is near the input end, as expected from a simple model of the noise compensation. We obtain relative frequency instabilities, expressed as overlapping Allan deviation, of 8x10-16 at 1 s averaging time and a few 10-19 at 1 day. These results are at the state-of-the-art for a link using urban telecommunication fibers. We also propose an improved scheme which delivers an ultra-stable signal of higher power, in order to feed a secondary link. In-line extraction opens the way to a broad distribution of an ultra-stable frequency reference, enabling a wide range of applications beyond metrology.

preprint2014arXiv

Quantum cascade laser frequency stabilisation at the sub-Hz level

Quantum Cascade Lasers (QCL) are increasingly being used to probe the mid-infrared "molecular fingerprint" region. This prompted efforts towards improving their spectral performance, in order to reach ever-higher resolution and precision. Here, we report the stabilisation of a QCL onto an optical frequency comb. We demonstrate a relative stability and accuracy of 2x10-15 and 10-14, respectively. The comb is stabilised to a remote near-infrared ultra-stable laser referenced to frequency primary standards, whose signal is transferred via an optical fibre link. The stability and frequency traceability of our QCL exceed those demonstrated so far by two orders of magnitude. As a demonstration of its capability, we then use it to perform high-resolution molecular spectroscopy. We measure absorption frequencies with an 8x10-13 relative uncertainty. This confirms the potential of this setup for ultra-high precision measurements with molecules, such as our ongoing effort towards testing the parity symmetry by probing chiral species.

preprint2014arXiv

Semiparametric inference for the recurrent event process by means of a single-index model

In this paper, we introduce new parametric and semiparametric regression techniques for a recurrent event process subject to random right censoring. We develop models for the cumula- tive mean function and provide asymptotically normal estimators. Our semiparametric model which relies on a single-index assumption can be seen as a dimension reduction technique that, contrary to a fully nonparametric approach, is not stroke by the curse of dimensional- ity when the number of covariates is high. We discuss data-driven techniques to choose the parameters involved in the estimation procedures and provide a simulation study to support our theoretical results.

preprint2014arXiv

Tackling the Limits of Optical Fiber Links

We theoretically and experimentally investigate relevant noise processes arising in optical fiber links, which fundamentally limit their relative stability. We derive the unsuppressed delay noise for three configurations of optical links: two-way method, Sagnac interferometry, and actively compensated link, respectively designed for frequency comparison, rotation sensing, and frequency transfer. We also consider an alternative two-way setup allowing real-time frequency comparison and demonstrate its effectiveness on a proof-of-principle experiment with a 25-km fiber spool. For these three configurations, we analyze the noise arising from uncommon fiber paths in the interferometric ensemble and design optimized interferometers. We demonstrate interferometers with very low temperature sensitivity of respectively -2.2, -0.03 and 1 fs/K. We use one of these optimized interferometers on a long haul compensated fiber link of 540km. We obtain a relative frequency stability of 3E-20 after 10,000 s of integration time.

preprint2014arXiv

Two-Way Optical Frequency Comparisons Over 100km Telecommunication Network Fibers

By using two-way frequency transfer, we demonstrate ultra-high resolution comparison of optical frequencies over a telecommunication fiber link of 100 km operating simultaneously digital data transfer. We first propose and experiment a bi-directional scheme using a single fiber. We show that the relative stability at 1 s integration time is 7 10^18 and scales down to 5 10^21. The same level of performance is reached when an optical link is implemented with an active compensation of the fiber noise. We also implement a real-time two-way frequency comparison over a uni-directional telecommunication network using a pair of parallel fibers. The relative frequency stability is 10^15 at 1 s integration time and reaches 2 10^17 at 40 000 s. The fractional uncertainty of the frequency comparisons was evaluated for the best case to 2 10^20. These results open the way to accurate and high resolution frequency comparison of optical clocks over intercontinental fiber networks.

preprint2013arXiv

Mid-infrared laser phase-locking to a remote near-infrared frequency reference for high precision molecular spectroscopy

We present a new method for accurate mid-infrared frequency measurements and stabilization to a near-infrared ultra-stable frequency reference, transmitted with a long-distance fibre link and continuously monitored against state-of-the-art atomic fountain clocks. As a first application, we measure the frequency of an OsO4 rovibrational molecular line around 10 $μ$m with a state-of-the-art uncertainty of 8x10-13. We also demonstrate the frequency stabilization of a mid-infrared laser with fractional stability better than 4x10-14 at 1 s averaging time and a line-width below 17 Hz. This new stabilization scheme gives us the ability to transfer frequency stability in the range of 10-15 or even better, currently accessible in the near-infrared or in the visible, to mid-infrared lasers in a wide frequency range.

preprint2013arXiv

Nuclear stopping for heavy-ion induced reactions in the Fermi Energy range : from 1-Body to 2-Body dissipation

We address the stopping in heavy-ion induced reactions around the Fermi energy using central collisions recorded with \emph{INDRA} $4π$ array. The stopping is minimal around the Fermi energy and corresponds to the disappearance of the Mean-Field effects and the appearance of nucleon-nucleon elastic collisions. This phenomenon is attributed to a change in the dissipation regime going from 1-body (Mean-Field) dissipation at low incident energy to 2- body (nucleonic collisions) above the Fermi energy. A connection to the in-medium transport properties of nuclear matter is proposed and comprehensive values of the nucleon mean free path $λ_{NN}$ and the nucleon-nucleon cross section are extracted.

preprint2013arXiv

Single index regression models in the presence of censoring depending on the covariates

Consider a random vector (X',Y)', where X is d-dimensional and Y is one-dimensional. We assume that Y is subject to random right censoring. The aim of this paper is twofold. First, we propose a new estimator of the joint distribution of (X',Y)'. This estimator overcomes the common curse-of-dimensionality problem, by using a new dimension reduction technique. Second, we assume that the relation between X and Y is given by a mean regression single index model, and propose a new estimator of the parameters in this model. The asymptotic properties of all proposed estimators are obtained.

preprint2012arXiv

Mid-IR frequency measurement using an optical frequency comb and a long-distance remote frequency reference

We have built a frequency chain which enables to measure the absolute frequency of a laser emitting in the 28-31 THz frequency range and stabilized onto a molecular absorption line. The set-up uses an optical frequency comb and an ultrastable 1.55 $μ$m frequency reference signal, transferred from LNE-SYRTE to LPL through an optical link. We are now progressing towards the stabilization of the mid-IR laser via the frequency comb and the extension of this technique to quantum cascade lasers. Such a development is very challenging for ultrahigh resolution molecular spectroscopy and fundamental tests of physics with molecules.

preprint2012arXiv

Simultaneous remote transfer of accurate timing and optical frequency over a public fiber network

In this work we demonstrate for the first time that it is possible to transfer simultaneously an ultra-stable optical frequency and a precise and accurate timing over 540 km using a public telecommunication optical fiber networks with Internet data. The optical phase is used to carry both the frequency information and the timestamps by modulating a very narrow optical carrier at 1.55 $μ$m with spread spectrum signals using two-way satellite time transfer modems. The results in term of absolute time accuracy (250 ps) and long-term timing stability (20 ps) well outperform the conventional Global Navigation Satellite System or geostationary transfer methods.

preprint2012arXiv

Ultra-stable long distance optical frequency distribution using the Internet fiber network

We report an optical link of 540 km for ultrastable frequency distribution over the Internet fiber network. The stable frequency optical signal is processed enabling uninterrupted propagation on both directions. The robustness and the performance of the link are enhanced by a cost effective fully automated optoelectronic station. This device is able to coherently regenerate the return optical signal with a heterodyne optical phase locking of a low noise laser diode. Moreover the incoming signal polarization variation are tracked and processed in order to maintain beat note amplitudes within the operation range. Stable fibered optical interferometer enables optical detection of the link round trip phase signal. The phase-noise compensated link shows a fractional frequency instability in 10 Hz bandwidth of 5x10-15 at one second measurement time and 2x10-19 at 30 000 s. This work is a significant step towards a sustainable wide area ultrastable optical frequency distribution and comparison network.

preprint2010arXiv

Cascaded multiplexed optical link on a telecommunication network for frequency dissemination

We demonstrate a cascaded optical link for ultrastable frequency dissemination comprised of two compensated links of 150 km and a repeater station. Each link includes 114 km of Internet fiber simultaneously carrying data traffic through a dense wavelength division multiplexing technology, and passes through two routing centers of the telecommunication network. The optical reference signal is inserted in and extracted from the communication network using bidirectional optical add-drop multiplexers. The repeater station operates autonomously ensuring noise compensation on the two links and the ultra-stable signal optical regeneration. The compensated link shows a fractional frequency instability of 3 \times 10-15 at one second measurement time and 5 \times 10-20 at 20 hours. This work paves the way to a wide dissemination of ultra-stable optical clock signals between distant laboratories via the Internet network.

preprint2009arXiv

Determination of the Boltzmann constant by laser spectroscopy as a basis for future measurements of the thermodynamic temperature

In this paper, we present the latest results on the measurement of the Boltzmann constant kB, by laser spectroscopy of ammonia at 10 ?m. The Doppler absorption profile of a ro-vibrational line of an NH3 gas sample at thermal and pressure equilibrium is measured as accurately as possible. The absorption cell is placed inside a large 1m3 thermostat filled with an ice-water mixture, which sets the temperature very close to 273.15 K. Analysing this profile, which is related to the Maxwell-Boltzmann molecular speed distribution, leads to a determination of the Boltzmann constant via a measurement of the Doppler width (proportional tosqrt(kBT)). A spectroscopic determination of the Boltzmann constant with an uncertainty as low as 37 ppm is obtained. Recent improvements with a new passive thermostat lead to a temperature accuracy, stability and homogeneity of the absorption cell better than 1 ppm over a day.

preprint2009arXiv

High-resolution optical frequency dissemination on a telecommunication network with data traffic

We transferred the frequency of an ultra-stable laser over a 108 km urban fiber link comprising 22 km of optical communications network fiber simultaneously carrying Internet data traffic. The metrological signal and the digital data signal are transferred on two different frequency channels in a dense wavelength division multiplexing scheme. The metrological signal is inserted into and extracted from the communications network by using bidirectional off-the-shelf optical add-drop multiplexers. The link-induced phase noise is measured and cancelled with round-trip technique using an all-fiber-based interferometer. The compensated link shows an Allan deviation of a few 10-16 at one second and below 10-19 at 10,000 seconds. This opens the way to a wide dissemination of ultra stable optical clock signals between distant laboratories via the Internet network.

preprint2009arXiv

Measurement of the Boltzmann constant by the Doppler broadening technique at a 3,8x10-5 accuracy level

In this paper, we describe an experiment performed at the Laboratoire de Physique des Lasers and dedicated to an optical measurement of the Boltzmann constant. With the proposed innovative technique, determining comes down to an ordinary frequency measurement. The method consists in measuring as accurately as possible the Doppler absorption profile of a rovibrational line of ammonia in thermal equilibrium. This profile is related to the Maxwell-Boltzmann molecular velocity distribution along the laser beam. A fit of the absorption line shape leads to a determination of the Doppler width proportional to sqrt(kT) and thus to a determination of the Boltzmann constant. The laser source is an ultra-stable CO2 laser with a wavelength . The absorption cell is placed in a thermostat keeping the temperature at 273.15 K within 1.4 mK. We were able to measure with a relative uncertainty as small as 3.8x10-5, which represents an improvement of an order of magnitude for an integration time comparable to our previous measurement published in 2007 [1]

preprint2005arXiv

Frequency modulated laser beam with highly efficient intensity stabilisation

We analyse the limitation of the amplitude modulation rejection due to the spatial modulation of the output beam of an acousto-optic modulator used in an active laser beam stabilisation system when a frequency modulation of a few megahertz is applied to this modulator. We show how to overcome this problem, using a single mode optical fibre at the output of the modulator. A residual amplitude modulation of 10-5 is achieved.

preprint2005arXiv

Long-distance frequency dissemination with a resolution of 10-17

We use a new technique to disseminate microwave reference signals along ordinary optical fiber. The fractional frequency resolution of a link of 86 km in length is 10-17 for a one day integration time, a resolution higher than the stability of the best microwave or optical clocks. We use the link to compare the microwave reference and a CO2/OsO4 frequency standard that stabilizes a femtosecond laser frequency comb. This demonstrates a resolution of 3.10-14 at 1 s. An upper value of the instability introduced by the femtosecond laser-based synthesizer is estimated as 1.10-14 at 1 s.