Researcher profile

Giorgio Santarelli

Giorgio Santarelli contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
7works
0followers
8topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2019arXiv

Quantum cascade laser-pumped terahertz molecular lasers: frequency noise and phase-locking using a 1560nm frequency comb

The recent demonstration of a terahertz (THz) molecular gas laser pumped by a mid-infrared quantum cascade laser (QCL) has opened up new perspectives for this family of sources, traditionally relying on CO2-laser pumping. A so far open question concerning QCL-pumped THz molecular lasers (MLs) is related to their spectral purity. Indeed, assessing their frequency/phase noise is crucial for a number of applications potentially exploiting these sources as local oscillators. Here this question is addressed by reporting the measurement of the frequency noise power spectral density (PSD) of a THz ML pumped by a 10.3μm-wavelength QCL, and emitting 1mW at 1.1THz in continuous wave. This is achieved by beating the ML frequency with the 1080th harmonic of the repetition rate of a 1560nm frequency comb. We find a frequency noise PSD < 10Hz2/Hz (-95dBc/Hz) at 100kHz from the carrier. To demonstrate the effect of the stability of the pump laser on the spectral purity of the THz emission we also measure the frequency noise PSD of a CO2-laser-pumped 2.5THz ML, reaching 0.1Hz2/Hz (-105dBc/Hz) at 40kHz from the carrier, limited by the frequency noise of the frequency comb harmonic. Finally, we show that it is possible to actively phase-lock the QCL-pumped molecular laser to the frequency comb repetition rate harmonic by controlling the QCL current, demonstrating a sub-Hz linewidth.

preprint2012arXiv

Progress in Atomic Fountains at LNE-SYRTE

We give an overview of the work done with the Laboratoire National de Métrologie et d&#39;Essais-Systèmes de Référence Temps-Espace (LNE-SYRTE) fountain ensemble during the last five years. After a description of the clock ensemble, comprising three fountains, FO1, FO2, and FOM, and the newest developments, we review recent studies of several systematic frequency shifts. This includes the distributed cavity phase shift, which we evaluate for the FO1 and FOM fountains, applying the techniques of our recent work on FO2. We also report calculations of the microwave lensing frequency shift for the three fountains, review the status of the blackbody radiation shift, and summarize recent experimental work to control microwave leakage and spurious phase perturbations. We give current accuracy budgets. We also describe several applications in time and frequency metrology: fountain comparisons, calibrations of the international atomic time, secondary representation of the SI second based on the 87Rb hyperfine frequency, absolute measurements of optical frequencies, tests of the T2L2 satellite laser link, and review fundamental physics applications of the LNE-SYRTE fountain ensemble. Finally, we give a summary of the tests of the PHARAO cold atom space clock performed using the FOM transportable fountain.

preprint2012arXiv

Simultaneous remote transfer of accurate timing and optical frequency over a public fiber network

In this work we demonstrate for the first time that it is possible to transfer simultaneously an ultra-stable optical frequency and a precise and accurate timing over 540 km using a public telecommunication optical fiber networks with Internet data. The optical phase is used to carry both the frequency information and the timestamps by modulating a very narrow optical carrier at 1.55 $μ$m with spread spectrum signals using two-way satellite time transfer modems. The results in term of absolute time accuracy (250 ps) and long-term timing stability (20 ps) well outperform the conventional Global Navigation Satellite System or geostationary transfer methods.

preprint2011arXiv

Ultra stable and very low noise signal source using a cryocooled sapphire oscillator for VLBI

Here we present the design and implementation of a novel frequency synthesizer based on low phase noise digital dividers and a direct digital synthesizer. The synthesis produces two low noise accurate and tunable signals at 10 MHz and 100 MHz. We report on the measured residual phase noise and frequency stability of the synthesizer, and estimate the total frequency stability, which can be expected from the synthesizer seeded with a signal near 11.2 GHz from an ultra-stable cryocooled sapphire oscillator. The synthesizer residual single sideband phase noise, at 1 Hz offset, on 10 MHz and 100 MHz signals, respectively, were measured to be -135 dBc/Hz and -130 dBc/Hz. Their intrinsic frequency stability contributions, on the 10 MHz and 100 MHz signals, respectively, were measured as sigma_y = 9 x 10^-15 and sigma_y = 2.2 x 10^-15, at 1 s integration time. The Allan Deviation of the total fractional frequency noise on the 10 MHz and 100 MHz signals derived from the synthesizer with the cryocooled sapphire oscillator, may be estimated as sigma_y = 5.2 x 10^-15 τ^-1 + 3.6 x 10^-15 τ^-1/2 + 4 x 10^-16 and sigma_y = 2 x 10^-15 τ^-1/2 + 3 x 10^-16, respectively, for 1 s < τ< 10^4 s. We also calculate the coherence function, (a figure of merit in VLBI) for observation frequencies of 100 GHz, 230 GHz and 345 GHz, when using the cryocooled sapphire oscillator and an hydrogen maser. The results show that the cryocooled sapphire oscillator offers a significant advantage at frequencies above 100 GHz.

preprint2010arXiv

An agile laser with ultra-low frequency noise and high sweep linearity

We report on a fiber-stabilized agile laser with ultra-low frequency noise. The frequency noise power spectral density is comparable to that of an ultra-stable cavity stabilized laser at Fourier frequencies higher than 30 Hz. When it is chirped at a constant rate of ~ 40 MHz/s, the max non-linearity frequency error is about 50 Hz peak-to-peak over more than 600 MHz tuning range. The Rayleigh backscattering is found to be a significant frequency noise source dependent on fiber length, chirping rate and the power imbalance of the interferometer arms. We analyze this effect both theoretically and experimentally and put forward techniques to reduce this noise contribution.

preprint2009arXiv

Testing Local Lorentz and Position Invariance and Variation of Fundamental Constants by searching the Derivative of the Comparison Frequency Between a Cryogenic Sapphire Oscillator and Hydrogen Maser

The cryogenic sapphire oscillator (CSO) at the Paris Observatory has been continuously compared to various Hydrogen Masers since 2001. The early data sets were used to test Local Lorentz Invariance in the Robertson-Mansouri-Sexl (RMS) framework by searching for sidereal modulations with respect to the Cosmic Microwave Background, and represent the best Kennedy-Thorndike experiment to date. In this work we present continuous operation over a period of greater than six years from September 2002 to December 2008 and present a more precise way to analyze the data by searching the time derivative of the comparison frequency. Due to the long-term operation we are able to search both sidereal and annual modulations. The results gives P_{KT} = β_{RMS}-α_{RMS}-1 = -1.7(4.0) \times 10^{-8} for the sidereal and -23(10) \times 10^{-8} for the annual term, with a weighted mean of -4.8(3.7) \times 10^{-8}, a factor of 8 better than previous. Also, we analyze the data with respect to a change in gravitational potential for both diurnal and annual variations. The result gives β_{H-Maser} - β_{CSO} = -2.7(1.4) \times 10^{-4} for the annual and -6.9(4.0) \times 10^{-4} for the diurnal terms, with a weighted mean of -3.2(1.3) \times 10^{-4}. This result is two orders of magnitude better than other tests that use electromagnetic resonators. With respect to fundamental constants a limit can be provided on the variation with ambient gravitational potential and boost of a combination of the fine structure constant (α), the normalized quark mass (m_q), and the electron to proton mass ratio (m_e/m_p), setting the first limit on boost dependence of order 10^{-10}.

preprint2005arXiv

Recent Experimental Tests of Special Relativity

We review our recent Michelson-Morley (MM) and Kennedy-Thorndike (KT) experiment, which tests Lorentz invariance in the photon sector, and report first results of our ongoing atomic clock test of Lorentz invariance in the matter sector. The MM-KT experiment compares a cryogenic microwave resonator to a hydrogen maser, and has set the most stringent limit on a number of parameters in alternative theories to special relativity. We also report first results of a test of Lorentz invariance in the SME (Standard Model Extension) matter sector, using Zeeman transitions in a laser cooled Cs atomic fountain clock. We describe the experiment together with the theoretical model and analysis. Recent experimental results are presented and we give a first estimate of components of the $\tilde{c}^p$ parameters of the SME matter sector. A full analysis of systematic effects is still in progress, and will be the subject of a future publication together with our final results. If confirmed, the present limits would correspond to first ever measurements of some $\tilde{c}^p$ components, and improvements by 11 and 14 orders of magnitude on others.