Source author record

Nathalie Picqué

Nathalie Picqué appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

16works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

16 published item(s)

preprint2021arXiv

Roadmap on multimode light shaping

Our ability to generate new distributions of light has been remarkably enhanced in recent years. At the most fundamental level, these light patterns are obtained by ingeniously combining different electromagnetic modes. Interestingly, the modal superposition occurs in the spatial, temporal as well as spatio-temporal domain. This generalized concept of structured light is being applied across the entire spectrum of optics: generating classical and quantum states of light, harnessing linear and nonlinear light-matter interactions, and advancing applications in microscopy, spectroscopy, holography, communication, and synchronization. This Roadmap highlights the common roots of these different techniques and thus establishes links between research areas that complement each other seamlessly. We provide an overview of all these areas, their backgrounds, current research, and future developments. We highlight the power of multimodal light manipulation and want to inspire new eclectic approaches in this vibrant research community.

preprint2020arXiv

An integrated lithium-niobate electro-optic platform for spectrally tailored dual-comb spectroscopy

A high-resolution broad-spectral-bandwidth spectrometer on a chip would create new opportunities for gas-phase molecular fingerprinting, especially in environmental sensing. A resolution high enough to observe transitions at atmospheric pressure and the simultaneous sensitive detection of multiple atoms or molecules are the key challenges. Here, an electro-optic microring-based dual-comb interferometer, fabricated on a low-loss lithium-niobate-on-insulator nanophotonic platform, demonstrates significant progress towards such an achievement. Spectra spanning 1.6 THz (53 cm-1) at a resolution of 10 GHz (0.33 cm-1) are obtained in a single measurement without requiring frequency scanning or moving parts. The frequency agility of the system enables spectrally-tailored multiplexed sensing, which allows for interrogation of non-adjacent spectral regions, here separated by 6.6 THz (220 cm-1), without compromising the signal-to-noise ratio.

preprint2020arXiv

An on-chip III-V-semiconductor-on-silicon laser frequency comb for gas-phase molecular spectroscopy in real-time

Frequency combs, spectra of evenly-spaced narrow phase-coherent laser lines, have revolutionized precision measurements. On-chip frequency comb generators hold much promise for fully-integrated instruments of time and frequency metrology. While outstanding developments are being reported with Kerr, quantum cascade and microring electro-optic combs, the field of high-resolution multiplexed gas-phase spectroscopy has remained inaccessible to such devices, because of their large line spacing, their small number of usable comb lines, the intensity variations between their comb lines, and their limited photonic integrability. Here we identify a path to broadband gas-phase spectroscopy on a chip. We design a low-noise III-V-on-silicon comb generator on a photonic chip, that emits a flat-top spectrum of 1400 lines at a repetition frequency of 1.0 GHz, a feature never approached by other ultra-miniaturized comb synthesizers. With dual-comb spectroscopy, our near-infrared electrically-pumped laser records high-resolution (1 GHz) sensitive multiplexed spectra with resolved comb lines, in times as short as 5 microseconds. Isotope-resolved 12C/13C detection in carbon monoxide is performed within 1 millisecond. With further developments, entire high-resolution spectroscopy laboratories-on-a-chip may be manufactured at the wafer scale. In environmental sensing, broad networks of spectrometers could be densely field-deployed to simultaneously monitor, in real time, sources and sinks of greenhouse gases, industrial pollution or noxious emissions of motor vehicles.

preprint2020arXiv

Dual-comb thin-disk oscillator

For the first time to our knowledge, a dual-comb laser based on thin-disk technology and its application to direct frequency comb spectroscopy are presented. The peak power (0.6 MW) and the average power (12 W) of our Yb:YAG thin-disk dual-comb system are more than one-order-of-magnitude higher than in any previous systems. The scheme allows easy adjustment of the repetition frequency difference during operation. A time-domain signal recorded over 10 μs without any active stabilization was sufficient to resolve individual comb lines after Fourier transformation. The demonstration should enable a wider adoption of dual-comb systems towards practical applications in research laboratories. Its simplicity and compactness especially for the realization of tri- and multi-comb systems and conversion into the still poorly covered UV and VUV ranges makes it a promising next-generation technology.

preprint2020arXiv

Upconversion mid-infrared dual-comb spectroscopy

We devise a new detection technique for mid-infrared multi-heterodyne spectroscopy. As an experimental implementation, mid-infrared light interrogates a gas sample in the 3-$μ$m region of the fundamental CH, OH, NH stretch in molecules and detection is performed in the near-infrared telecommunication region. Spectra showing 18000 resolved comb lines of 100-MHz spacing are recorded at a sensitivity close to the shot-noise limit. The demonstration adds to the unique advantages of dual-comb spectroscopy, such as potential very high resolution, negligible instrumental line width, and direct calibration of the frequency scale with an atomic clock. We also show that direct mid-infrared detection with a differential photo-detector module is beneficial in the limit of low mid-infrared average power.

preprint2014arXiv

Differential femtosecond coherent Stokes and anti-Stokes Raman spectroscopy

We demonstrate a novel technique of coherent Raman spectroscopy with a femtosecond laser. We apply to a molecular sample a sequence of pairs of ultrashort excitation and probe pulses, with a linearly increasing time delay between the two pulses from one pair to the next. We measure, as a function of the delay, the intensity modulation in the signal resulting from the differential detection of the Stokes and anti-Stokes radiations generated at the sample. The Fourier transform of such time-domain signal reveals the spectrum of the excited vibrational Raman transitions. The experimental proof-of-principle demonstrates high resolution, broad spectral span and suppression of the non-resonant background, as well as sensitivity enhancement due to the differential detection.

preprint2014arXiv

Few-cycle, Broadband, Mid-infrared Optical Parametric Oscillator Pumped by a 20-fs Ti:sapphire Laser

We report a few-cycle, broadband, singly-resonant optical parametric oscillator (OPO) for the mid-infrared based on MgO-doped periodically-poled LiNbO3 (MgO:PPLN), synchronously pumped by a 20-fs Ti:sapphire laser. By using crystal interaction lengths as short as 250 um, and careful dispersion management of input pump pulses and the OPO resonator, near-transform-limited, few-cycle idler pulses tunable across the mid-infrared have been generated, with as few as 3.7 optical cycles at 2682 nm. The OPO can be continuously tuned over 2179-3732 nm by cavity delay tuning, providing up to 33 mW of output power at 3723 nm. The idler spectra exhibit stable broadband profiles with bandwidths spaning over 422 nm (FWHM) recorded at 3732 nm. We investigate the effect of crystal length on spectral bandwidth and pulse duration at a fixed wavelength, confirming near-transform-limited idler pulses for all grating interaction lengths. By locking the repetition frequency of the pump laser to a radio-frequency reference, and without active stabilization of the OPO cavity length, an idler power stability better than 1.6% rms over >2.75 hours is obtained when operating at maximum output power, in excellent spatial beam quality with TEM00 mode profile.

preprint2013arXiv

Broadband high-resolution two-photon spectroscopy with laser frequency combs

Two-photon excitation spectroscopy with broad spectral span is demonstrated at Doppler-limited resolution. We describe first Fourier transform two-photon spectroscopy of an atomic sample with two mode-locked laser oscillators in a dual-comb technique. Each transition is uniquely identified by the modulation imparted by the interfering comb excitations. The temporal modulation of the spontaneous two-photon fluorescence is monitored with a single photodetector, and the spectrum is revealed by a Fourier transform.

preprint2009arXiv

Cavity-enhanced dual-comb spectroscopy

The sensitivity of molecular fingerprinting is dramatically improved when placing the absorbing sample in a high-finesse optical cavity, thanks to the large increase of the effective path-length. As demonstrated recently, when the equidistant lines from a laser frequency comb are simultaneously injected into the cavity over a large spectral range, multiple trace-gases may be identified within a few milliseconds. Analyzing efficiently the light transmitted through the cavity however still remains challenging. Here, a novel approach, cavity-enhanced frequency comb Fourier transform spectroscopy, fully overcomes this difficulty and measures ultrasensitive, broad-bandwidth, high-resolution spectra within a few tens of $μ$s. It could be implemented from the Terahertz to the ultraviolet regions without any need for detector arrays. We recorded, within 18 $μ$s, spectra of the 1.0 $μ$m overtone bands of ammonia spanning 20 nm with 4.5 GHz resolution and a noise-equivalent-absorption at one-second-averaging per spectral element of 3 10^-12 cm^-1Hz^-1/2, thus opening a route to time-resolved spectroscopy of rapidly-evolving single-events.

preprint2007arXiv

Continuous-wave 1.55 $μ$m diode-pumped surface emitting semiconductor laser for broadband multiplex spectroscopy

A room temperature operating Vertical External Cavity Surface Emitting Laser is applied around 1550 nm to intracavity laser absorption spectroscopy analyzed by time-resolved Fourier transform interferometry. At an equivalent pathlength of 15 km, the high resolution spectrum of the semiconductor disk laser emission covers 17 nm simultaneously. A noise equivalent absorption coefficient at one second averaging equal to 1.5 10^{-10} cm^{-1}.Hz^{-1/2} per spectral element is reported for the 65 km longest path length employed.

preprint2007arXiv

Femtosecond laser Fourier transform absorption spectroscopy

A femtosecond mode-locked laser is used for the first time as a broadband infrared source for high resolution Fourier transform absorption spectroscopy. Demontration is made with a Cr^4+:YAG laser. The entire nu_1+nu_3 vibration-rotation band region of acetylene, observed after passing through a single pass 80-cm long cell, is simultaneously recorded between 1480 and 1600 nm, in 7.9 s with a signal to noise ratio equal to 1000. Two hot bands of the most abundant acetylene isotopologue and the n1+n3 band of the ^13C^12CH_2 are also present. The noise equivalent absorption coefficient at one second averaging is equal to 7 10^{-7} cm^{-1}.Hz^{-1/2} per spectral element.

preprint2006arXiv

Acetylene weak bands at 2.5 $μ$m from intracavity Cr2+:ZnSe laser absorption observed with time-resolved Fourier transform spectroscopy

The spectral dynamics of a mid-infrared multimode Cr^2+:ZnSe laser located in a vacuum sealed chamber containing acetylene at low pressure is analyzed by a stepping-mode high-resolution time-resolved Fourier transform interferometer. Doppler-limited absorption spectra of C_2H_2 in natural isotopic abundance are recorded around 4000 cm^-1 with kilometric absorption path lengths and sensitivities better than 3 10^-8 cm-1. Two cold bands are newly identified and assigned to the n_1+n_4^1 and n_3+n_5^1 transitions of ^12C^13CH_2. The n_1+n_5^1 band of ^12C_2HD and fourteen ^12C_2H_2 bands are observed, among which for the first time n_2+2n_4^2+n_5^-1.

preprint2006arXiv

Cation-like Doppler shifts from a neutral molecule in an electrical discharge

Velocity-modulation Fourier transform emission spectra from a N_2O/He discharge plasma recorded between 1 and 5.5 $μ$m are described. Surprisingly, they show Doppler-shifted lines for the E ^2 Σ^+ - D ^2 Σ^+, C ^2 Π- A ^2 Σ^+, and D ^2 Σ^+ - A ^2 Σ^+ Rydberg-Rydberg rovibronic transitions of the nitric oxide neutral molecule. These polarity-dependent Doppler-shifts are those of positively charged particles. Vibration-rotation lines of NO and transitions from other neutral molecules like N_2 are also present in the spectra with comparable intensities and remain unshifted. Experimental investigations and possible explanations are discussed.

preprint2006arXiv

N_2O weak lines observed between 3900 and 4050 cm^-1 from long path absorption spectra

Previously unobserved nitrous oxide transitions around 2.5 $μ$m are measured by intracavity laser absorption spectroscopy (ICLAS) analyzed by time-resolved Fourier transform (TRFT) spectrometer. With an accuracy of the order of 10^-3 cm^-1, measured positions of 1637 assigned weak transitions are provided. They belong to 42 vibrational transitions, among which 33 are observed for the first time. These data are believed to be useful in particular to monitoring atmosphere purposes.

preprint2006arXiv

Time-resolved Fourier transform intracavity spectroscopy with a Cr2+:ZnSe laser

Intracavity laser absorption spectroscopy (ICLAS) with an evacuated Cr2+: ZnSe laser is performed with a high-resolution time-resolved Fourier transform interferometer with a minimum detectable absorption coefficient equal to 4 10-9 cm-1 Hz-1/2 in the 2.5$μ$m region. This represents the extreme limit presently reached in the infrared by ICLAS with Doppler limited resolution. The broad gain band of the crystal allows a spectral coverage at most equal to 125 nm, wide enough to see entire vibration bands. Weak CO2 bands observed up to now only in the Venus atmosphere are recorded for the first time in a laboratory. H2O detection limit down to 0.9 ppbv is also demonstrated.