Researcher profile

Mats Persson

Mats Persson contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - UnverifiedVerification L1Unclaimed author
5works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2022arXiv

Dimensionality and Background Cancellation in Energy Selective X-Ray Imaging

Purpose: The set of linear attenuation coefficients that belong to materials in the human body is commonly assumed to be spanned by two basis functions in the range of clinical x-ray energies, even though there is evidence that the dimensionality of this set is greater than two. It has not yet been clear that the use of a third basis function could be beneficial in absence of contrast agents. Approach: In this work, the choice of the number of basis functions used in the basis decomposition method is studied for the task of producing an image where a third material is separated from a background of two other materials, in a case where none of the materials have a K-edge in the range of considered x-ray energies (20-140 keV). The case of separating iron from mixtures of liver and adipose tissue is studied with a simulated phantom which incorporates random and realistic tissue variability. Results: Inclusion of a third basis function improves the quantitative estimate of iron concentration by several orders of magnitude in terms of mean squared error in the resulting image. Conclusions: The inclusion of a third basis function in the basis decomposition is essential for the studied imaging task and could have potential application for quantitative estimation of iron concentration from material decomposed images.

preprint2022arXiv

Normalization of the task-dependent detective quantum efficiency of spectroscopic x-ray imaging detectors

Spectroscopic x-ray detectors (SXDs) are poised to play a substantial role in the next generation of medical x-ray imaging. Evaluating their performance in terms of the detective quantum efficiency (DQE) requires normalization of the frequency-dependent signal-to-noise ratio (SNR) by that of an ideal SXD. We provide mathematical expressions of the SNR of ideal SXDs for quantification and detection tasks and tabulate their numeric values for standardized tasks. We propose using standardized RQA-series x-ray spectra. We define ideal SXDs as those that (1) have an infinite number of infinitesimal energy bins, (2) do not distort the incident distribution of x-ray photons in the spatial or energy domains, and (3) do not decrease the frequency-dependent SNR of the incident distribution of x-ray quanta. We derive analytic expressions for the noise power spectrum (NPS) of such ideal detectors for detection and quantification tasks. We tabulate the NPS of ideal SXDs for RQA x-ray spectra for detection and quantification of aluminum, PMMA, iodine, and gadolinium basis materials. Our analysis shows that a single matrix determines the noise power of ideal SXDs in detection and quantification tasks, including basis material decomposition and line-integral estimation for pseudo-mono-energetic imaging. This NPS matrix is determined by the x-ray spectrum incident on the detector and the mass-attenuation coefficients of the set of basis materials. Combining existing tabulated values of the mass-attenuation coefficients of basis materials with standardized RQA x-ray spectra enabled tabulating numeric values of the NPS matrix for selected spectra and tasks. The numeric values and mathematical expressions of the NPS of ideal SXDs reported here can be used to normalize measurements of the frequency-dependent SNR of SXDs for experimental study of the task-dependent DQE.

preprint2022arXiv

The effects of intra-detector Compton scatter on zero-frequency DQE for photon-counting CT using edge-on-irradiated silicon detectors

Background: Edge-on-irradiated silicon detectors are currently being investigated for use in photon-counting CT applications. The low atomic number of silicon leads to a significant number of incident photons being Compton scattered in the detector, depositing a part of their energy and potentially being counted multiple times. Although the physics of Compton scatter is well established, the effects of Compton interactions in the detector on image quality for an edge-on-irradiated silicon detector have still not been thoroughly investigated. Purpose: To investigate and explain effects of Compton scatter on zero-frequency DQE for photon-counting CT using edge-on-irradiated silicon detectors. Methods: We extend an existing Monte Carlo model of an edge-on-irradiated silicon detector to develop projection and image domain performance metrics for pure density and pure spectral imaging tasks. We show that the lowest energy threshold of the detector can be used as an effective discriminator of primary counts and cross-talk caused by Compton scatter. We study the developed metrics as functions of the lowest threshold energy. Results: Density imaging performance decreases monotonically as a function of the lowest threshold in both projection and image domains. Spectral imaging performance has a plateau between 0 and 10 keV and decreases monotonically thereafter, in both projection and image domain. Conclusions: Compton interactions contribute significantly to the density imaging performance of edge-on-irradiated silicon detectors. With the studied detector topology, the benefit of counting primary Compton interactions outweighs the penalty of multiple counting at all lower threshold energies. Compton interactions also contribute significantly to the spectral imaging performance for measured energies above 10 keV.

preprint2021arXiv

Development and evaluation of a 3D annotation software for interactive COVID-19 lesion segmentation in chest CT

Segmentation of COVID-19 lesions from chest CT scans is of great importance for better diagnosing the disease and investigating its extent. However, manual segmentation can be very time consuming and subjective, given the lesions' large variation in shape, size and position. On the other hand, we still lack large manually segmented datasets that could be used for training machine learning-based models for fully automatic segmentation. In this work, we propose a new interactive and user-friendly tool for COVID-19 lesion segmentation, which works by alternating automatic steps (based on level-set segmentation and statistical shape modeling) with manual correction steps. The present software was tested by two different expertise groups: one group of three radiologists and one of three users with an engineering background. Promising segmentation results were obtained by both groups, which achieved satisfactory agreement both between- and within-group. Moreover, our interactive tool was shown to significantly speed up the lesion segmentation process, when compared to fully manual segmentation. Finally, we investigated inter-observer variability and how it is strongly influenced by several subjective factors, showing the importance for AI researchers and clinical doctors to be aware of the uncertainty in lesion segmentation results.

preprint2020arXiv

Detective quantum efficiency of photon-counting CdTe and Si detectors for computed tomography: a simulation study

Purpose: Developing photon-counting CT detectors requires understanding the impact of parameters such as converter material, absorption length and pixel size. We apply a novel linear-systems framework, incorporating spatial and energy resolution, to study realistic silicon (Si) and cadmium telluride (CdTe) detectors at low count rate. Approach: We compared CdTe detector designs with $0.5\times0.5\; \mathrm{mm}^2$ and $0.225\times0.225\; \mathrm{mm}^2$ pixels and Si detector designs with $0.5\times0.5\; \mathrm{mm}^2$ pixels of 30 and 60 mm active absorption length, with and without tungsten scatter blockers. Monte-Carlo simulations of photon transport were used together with Gaussian charge sharing models fitted to published data. Results: For detection in a 300 mm thick object at 120 kVp, the 0.5 mm and 0.225 mm pixel CdTe systems have 28-41 $\%$ and 5-29 $\%$ higher DQE, respectively, than the 60 mm Si system with tungsten, whereas the corresponding numbers for two-material decomposition are 2 $\%$ lower to 11 $\%$ higher DQE and 31-54 $\%$ lower DQE compared to Si. We also show that combining these detectors with dual-spectrum acquisition is beneficial. Conclusions: In the low-count-rate regime, CdTe detector systems outperform the Si systems for detection tasks, while silicon outperforms one or both of the CdTe systems for material decomposition.