Researcher profile

Fredrik Grönberg

Fredrik Grönberg contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2022arXiv

Dimensionality and Background Cancellation in Energy Selective X-Ray Imaging

Purpose: The set of linear attenuation coefficients that belong to materials in the human body is commonly assumed to be spanned by two basis functions in the range of clinical x-ray energies, even though there is evidence that the dimensionality of this set is greater than two. It has not yet been clear that the use of a third basis function could be beneficial in absence of contrast agents. Approach: In this work, the choice of the number of basis functions used in the basis decomposition method is studied for the task of producing an image where a third material is separated from a background of two other materials, in a case where none of the materials have a K-edge in the range of considered x-ray energies (20-140 keV). The case of separating iron from mixtures of liver and adipose tissue is studied with a simulated phantom which incorporates random and realistic tissue variability. Results: Inclusion of a third basis function improves the quantitative estimate of iron concentration by several orders of magnitude in terms of mean squared error in the resulting image. Conclusions: The inclusion of a third basis function in the basis decomposition is essential for the studied imaging task and could have potential application for quantitative estimation of iron concentration from material decomposed images.

preprint2022arXiv

Reconstructing Accurate Synthetic Hounsfield Units with Spectral CT Data

Purpose: To evaluate a proposed method to reconstruct CT numbers that accurately mimic conventional CT numbers from spectral CT data, as would have been produced by a conventional system without effects of beam hardening. Approach: We implement the proposed method for simulated ideal and non-ideal photon counting multi-bin systems, the latter based on a photon counting Silicon detector, and compare them with a simulated ideal conventional energy integrating system with a cupping correction algorithm. We compare the systems using a mathematical phantom of a size and composition that produces severe cupping and beam hardening artefacts when imaged with a conventional system with no cupping correction. Results: The resulting images show CT numbers that are consistently accurate for a varying range of tissues and are free of beam hardening artefacts. Conclusions: This method could facilitate use of established rules-of-thumb regarding absolute CT numbers for various organs and conditions during the transition from conventional CT to spectral CT.

preprint2022arXiv

The effects of intra-detector Compton scatter on zero-frequency DQE for photon-counting CT using edge-on-irradiated silicon detectors

Background: Edge-on-irradiated silicon detectors are currently being investigated for use in photon-counting CT applications. The low atomic number of silicon leads to a significant number of incident photons being Compton scattered in the detector, depositing a part of their energy and potentially being counted multiple times. Although the physics of Compton scatter is well established, the effects of Compton interactions in the detector on image quality for an edge-on-irradiated silicon detector have still not been thoroughly investigated. Purpose: To investigate and explain effects of Compton scatter on zero-frequency DQE for photon-counting CT using edge-on-irradiated silicon detectors. Methods: We extend an existing Monte Carlo model of an edge-on-irradiated silicon detector to develop projection and image domain performance metrics for pure density and pure spectral imaging tasks. We show that the lowest energy threshold of the detector can be used as an effective discriminator of primary counts and cross-talk caused by Compton scatter. We study the developed metrics as functions of the lowest threshold energy. Results: Density imaging performance decreases monotonically as a function of the lowest threshold in both projection and image domains. Spectral imaging performance has a plateau between 0 and 10 keV and decreases monotonically thereafter, in both projection and image domain. Conclusions: Compton interactions contribute significantly to the density imaging performance of edge-on-irradiated silicon detectors. With the studied detector topology, the benefit of counting primary Compton interactions outweighs the penalty of multiple counting at all lower threshold energies. Compton interactions also contribute significantly to the spectral imaging performance for measured energies above 10 keV.