Researcher profile

M. Nicklas

M. Nicklas contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - UnverifiedVerification L1Unclaimed author
5works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2020arXiv

Effect of chemical and hydrostatic pressure on the coupled magnetostructural transition of Ni-Mn-In Heusler alloys

Ni-Mn-In magnetic shape-memory Heusler alloys exhibit generally a large thermal hysteresis at their first-order martensitic phase transition which hinder a technological application in magnetic refrigeration. By optimizing the Cu content in Ni$_2$Cu$_x$Mn$_{1.4-x}$In$_{0.6}$, we obtained a thermal hysteresis of the martensitic phase transition in Ni$_{2}$Cu$_{0.2}$Mn$_{1.2}$In$_{0.6}$ of only 6 K. We can explain this very small hysteresis by an almost perfect habit plane at the interface of martensite and austenite phases. Application of hydrostatic pressure does not reduce the hysteresis further, but shifts the martensitic transition close to room temperature. The isothermal entropy change does not depend on warming or cooling protocols and is pressure independent. Experiments in pulsed-magnetic fields on Ni$_{2}$Cu$_{0.2}$Mn$_{1.2}$In$_{0.6}$ find a reversible magnetocaloric effect with a maximum adiabatic temperature change of -13 K.

preprint2020arXiv

High sensitivity heat capacity measurements on Sr2RuO4 under uniaxial pressure

A key question regarding the unconventional superconductivity of Sr$_2$RuO$_4$ remains whether the order parameter is single- or two-component. Under a hypothesis of two-component superconductivity, uniaxial pressure is expected to lift their degeneracy, resulting in a split transition. The most direct and fundamental probe of a split transition is heat capacity. Here, we report development of new high-frequency methodology for measurement of heat capacity of samples subject to large and highly homogeneous uniaxial pressure. We place an upper limit on the heat capacity signature of any second transition of a few per cent of the primary superconducting transition. The normalized jump in heat capacity, $ΔC/C$, grows smoothly as a function of uniaxial pressure, but we find no qualitative evidence of a pressure-induced order parameter transition. Thanks to the high precision of our measurements, these findings place stringent constraints on theories of the superconductivity of Sr$_2$RuO$_4$.

preprint2020arXiv

Improved magnetostructural and magnetocaloric reversibility in magnetic Ni-Mn-In shape-memory Heusler alloy by optimizing the geometric compatibility condition

We report an improved reversibility of magnetostriction and inverse magnetocaloric effect (MCE) for the magnetic shape-memory Heusler alloy Ni$_{1.8}$Mn$_{1.8}$In$_{0.4}$. We show that the magnetostriction and MCE crucially depends on the geometrical compatibility of the austenite and martensite phases. Detailed information on the compatibility of both phases has been obtained from the transformation matrix calculated from x-ray diffraction data. The uniqueness of the lattice parameters results in an improved reversibility of the magnetostriction and the MCE. In the thermal hysteresis region of the martensitic transformation, the maximum relative length change is 0.3% and the adiabatic temperature change $ΔT_{ad}\approx -10$ K in pulsed magnetic fields. Our results reveal that the approach of geometric compatibility will allow one to design materials with reversible magnetostriction and reversible inverse MCE at a first-order magnetostructural phase transition in shape-memory Heusler alloys.

preprint2020arXiv

Pressure tuning of the anomalous Hall effect in the chiral antiferromagnet Mn3Ge

We report on the pressure evolution of the giant anomalous Hall effect (AHE) in the chiral antiferromagnet Mn$_3$Ge. The AHE originating from the non-vanishing Berry curvature in Mn$_3$Ge can be continuously tuned by application of hydrostatic pressure. At room temperature, the Hall signal changes sign as a function of pressure and vanishes completely at $p=1.53$ GPa. Even though the Hall conductivity changes sign upon increasing pressure, the room-temperature saturation value of 23 ${\rm Ω^{-1}cm^{-1}}$ at 2.85 GPa is remarkably high and comparable to the saturation value at ambient pressure of about 40 ${\rm Ω^{-1}cm^{-1}}$. The change in the Hall conductivity can be directly linked to a gradual change of the size of the in-plane components of the Mn moments in the non-collinear triangular magnetic structure. Our findings, therefore, provide a route for tuning of the AHE in the chiral antiferromagnetic Mn$_3$Ge.

preprint2020arXiv

Reversible adiabatic temperature change in the shape memory Heusler alloy Ni2.2Mn0.8Ga: An effect of structural compatibility

The large magnetocaloric effect (MCE) observed in Ni-Mn based shape-memory Heusler alloys put them forward to use in magnetic refrigeration technology. It is associated with a first-order magnetostructural (martensitic) phase transition. We conducted a comprehensive study of the MCE for the off-stoichiometric Heusler alloy Ni$_{2.2}$Mn$_{0.8}$Ga in the vicinity of its first-order magnetostructural phase transition. We found a reversible MCE under repeated magnetic field cycles. The reversible behavior can be attributed to the small thermal hysteresis of the martensitic phase transition. Based on the analysis of our detailed temperature dependent X-ray diffraction data, we demonstrate the geometric compatibility of the cubic austenite and tetragonal martensite phases. This finding directly relates the reversible MCE behavior to an improved geometric compatibility condition between cubic austenite and tetragonal martensite phases. The approach will help to design shape-memory Heusler alloys with a large reversible MCE taking advantage of the first-order martensitic phase transition.