Source author record

Klaus Blaum

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

23works
10topics
4close collaborators

Published work

23 publications

preprint2022arXiv

Direct Bound-Electron gg factor Difference Measurement with Coupled Ions

The quantum electrodynamic (QED) description of light-and-matter interaction is one of the most fundamental theories of physics and has been shown to be in excellent agreement with experimental results. Specifically, measurements of the electronic magnetic moment (or gg factor) of highly charged ions (HCI) in Penning traps can provide a stringent probe for QED, testing the Standard model in the strongest electromagnetic fields. When studying the difference of isotopes, even the intricate effects stemming from the nucleus can be resolved and tested as, due to the identical electron configuration, many common QED contributions do not have to be considered. Experimentally however, this becomes quickly limited, particularly by the precision of the ion masses or the achievable magnetic field stability. Here we report on a novel measurement technique that overcomes both of these limitations by co-trapping two HCIs in a Penning trap and measuring the difference of their gg factors directly. The resulting correlation of magnetic field fluctuations leads to drastically higher precision. We use a dual Ramsey-type measurement scheme with the ions locked on a common magnetron orbit, separated by only a few hundred micrometres, to extract the coherent spin precession frequency difference. We have measured the isotopic shift of the bound electron gg factor of the neon isotopes of 20^{20}Ne9+^{9+} and 22^{22}Ne9+^{9+} to 0.56 parts-per-trillion (5.6⋅10−135.6 \cdot 10^{-13}) precision relative to their gg factors, which is an improvement of more than two orders of magnitude compared to state-of-the-art techniques. This resolves the QED contribution to the nuclear recoil for the very first time and accurately validates the corresponding theory. Furthermore, the agreement with theory allows setting constraints for a fifth-force, resulting from Higgs-portal-type dark-matter interactions.

preprint2022arXiv

Penning-trap mass measurements of the deuteron and the HD+ molecular ion

The masses of the lightest atomic nuclei and the electron mass are interlinked and are crucial in a wide range of research fields, with their values affecting observables in atomic, molecular and neutrino physics as well as metrology. The most precise values for these fundamental parameters come from Penning-trap mass spectrometry, which achieves relative mass uncertainties in the range of 10−1110^{-11}. However, redundancy checks using data from different experiments reveal significant inconsistencies in the masses of the proton (mpm_p), the deuteron (mdm_d) and helion (mhem_\text{he}), amounting to 55 standard deviations for the term Δ=mp+md−mheΔ=m_p+m_d-m_{\text{he}}, which suggests that the uncertainty of these values may have been underestimated. Here we present results from absolute mass measurements of the deuteron and the HD+{HD}^+ molecular ion against 12C^{12}C as a mass reference. Our value for the deuteron md=2.013 553 212 535(17)m_d=2.013\,553\,212\,535 (17)u supersedes the precision of the literature value by a factor of 2.42.4 and deviates from this by 4.84.8 standard deviations. With a relative uncertainty of 88 parts per trillion (ppt) this is the most precise mass value measured directly in atomic mass units. Furthermore, the measurement of the HD+{HD}^+ molecular ion, m(HD+)=3.021 378 241 561 (61)m({HD}^+)=3.021\,378\,241\,561\,(61)u, not only allows for a rigorous consistency check of our measurements of the masses of the deuteron (this work) and proton, but also establishes an additional link for the masses of tritium and helium-3 to the atomic mass unit. Combined with a recent measurement of the deuteron-to-proton mass ratio the uncertainty of the reference value of mpm_p can be reduced by a factor of three. This is a post-peer-review, pre-copyedit version of an article published in Nature. The final authenticated version is available online at https://doi.org/10.1038/s41586-020-2628-7

preprint2022arXiv

Perspectives on testing fundamental physics with highly charged ions in Penning traps

In Penning traps electromagnetic forces are used to confine charged particles under well-controlled conditions for virtually unlimited time. Sensitive detection methods have been developed to allow observation of single stored ions. Various cooling methods can be employed to reduce the energy of the trapped particle to nearly at rest. In this review we summarize how highly charged ions offer unique possibilities for precision measurements in Penning traps. Precision atomic and nuclear masses as well as magnetic moments of bound electrons allow among others to determine fundamental constants like the mass of the electron or to perform stringent tests of fundamental interactions like bound-state quantum electrodynamics. Recent results and future perspectives in high-precision Penning-trap spectroscopy with highly charged ions will be discussed.

preprint2021arXiv

Constraints on the Coupling between Axionlike Dark Matter and Photons Using an Antiproton Superconducting Tuned Detection Circuit in a Cryogenic Penning Trap

We constrain the coupling between axionlike particles (ALPs) and photons, measured with the superconducting resonant detection circuit of a cryogenic Penning trap. By searching the noise spectrum of our fixed-frequency resonant circuit for peaks caused by dark matter ALPs converting into photons in the strong magnetic field of the Penning-trap magnet, we are able to constrain the coupling of ALPs with masses around 2.7906−2.7914 neV/c22.7906-2.7914\,\textrm{neV/c}^2 to gaγ<1×10−11 GeV−1g_{aγ}< 1 \times 10^{-11}\,\textrm{GeV}^{-1}. This is more than one order of magnitude lower than the best laboratory haloscope and approximately 5 times lower than the CERN axion solar telescope (CAST), setting limits in a mass and coupling range which is not constrained by astrophysical observations. Our approach can be extended to many other Penning-trap experiments and has the potential to provide broad limits in the low ALP mass range.

preprint2020arXiv

QECQ_{\textrm{EC}}-value determination for 21^{21}Na→21\rightarrow^{21}Ne and 23^{23}Mg→23\rightarrow^{23}Na mirror-nuclei decays using high-precision mass spectrometry with ISOLTRAP at ISOLDE/CERN

We report on high-precision QECQ_{\textrm{EC}} values of the 21^{21}Na→21\rightarrow^{21}Ne and 23^{23}Mg→23\rightarrow^{23}Na mirror ββ-transitions from mass measurements with ISOLTRAP at ISOLDE/CERN. A precision of δm/m=9⋅10−10δm/m = 9 \cdot 10^{-10} and δm/m=1.5⋅10−9δm/m = 1.5 \cdot 10^{-9} was reached for the masses of 21^{21}Na and 23^{23}Mg, respectively. We reduce the uncertainty of the QECQ_{\textrm{EC}} values by a factor five, making them the most precise experimental input data for the calculation of the corrected Ft\mathcal{F} t-value of these mixed Fermi/Gamow-Teller transitions. For the 21^{21}Na→21\rightarrow^{21}Ne QECQ_{\textrm{EC}} value, a 2.3σ2.3 σ deviation from the literature QECQ_{\textrm{EC}}-value was found.

preprint2020arXiv

Detection of metastable electronic states by Penning trap mass spectrometry

State-of-the-art optical clocks achieve fractional precisions of 10−1810^{-18} and below using ensembles of atoms in optical lattices or individual ions in radio-frequency traps. Promising candidates for novel clocks are highly charged ions (HCIs) and nuclear transitions, which are largely insensitive to external perturbations and reach wavelengths beyond the optical range, now becoming accessible to frequency combs. However, insufficiently accurate atomic structure calculations still hinder the identification of suitable transitions in HCIs. Here, we report on the discovery of a long-lived metastable electronic state in a HCI by measuring the mass difference of the ground and the excited state in Re, the first non-destructive, direct determination of an electronic excitation energy. This result agrees with our advanced calculations, and we confirmed them with an Os ion with the same electronic configuration. We used the high-precision Penning-trap mass spectrometer PENTATRAP, unique in its synchronous use of five individual traps for simultaneous mass measurements. The cyclotron frequency ratio RR of the ion in the ground state to the metastable state could be determined to a precision of δR=1⋅10−11δR=1\cdot 10^{-11}, unprecedented in the heavy atom regime. With a lifetime of about 130 days, the potential soft x-ray frequency reference at ν=4.86⋅1016 Hzν=4.86\cdot 10^{16}\,\text{Hz} has a linewidth of only Δν≈5⋅10−8 HzΔν\approx 5\cdot 10^{-8}\,\text{Hz}, and one of the highest electronic quality factor (Q=νΔν≈1024Q=\fracν{Δν}\approx 10^{24}) ever seen in an experiment. Our low uncertainty enables searching for more HCI soft x-ray clock transitions, needed for promising precision studies of fundamental physics in a thus far unexplored frontier.

preprint2020arXiv

Examining the NN = 28 shell closure through high-precision mass measurements of 46−48^{46-48}Ar

The strength of the NN = 28 magic number in neutron-rich argon isotopes is examined through high-precision mass measurements of 46−48^{46-48}Ar, performed with the ISOLTRAP mass spectrometer at ISOLDE/CERN. The new mass values are up to 90 times more precise than previous measurements. While they suggest the persistence of the NN = 28 shell closure for argon, we show that this conclusion has to be nuanced in light of the wealth of spectroscopic data and theoretical investigations performed with the \emph{SDPF-U} phenomenological shell model interaction. Our results are also compared with \emph{ab initio} calculations using the Valence Space In-Medium Similarity Renormalization Group and the Self-Consistent Green's Function approaches. Both calculations provide a very good account of mass systematics at and around ZZ = 18 and, generally, a consistent description of the physics in this region. This combined analysis indicates that 46^{46}Ar is the transition between the closed-shell 48^{48}Ca and collective 44^{44}S.

preprint2020arXiv

High-precision mass spectrometer for light ions

The precise knowledge of the atomic masses of light atomic nuclei, e.g. the proton, deuteron, triton and helion, is of great importance for several fundamental tests in physics. However, the latest high-precision measurements of these masses carried out at different mass spectrometers indicate an inconsistency of five standard deviations. To determine the masses of the lightest ions with a relative precision of a few parts per trillion and investigate this mass problem a cryogenic multi-Penning trap setup, LIONTRAP (Light ION TRAP), was constructed. This allows an independent and more precise determination of the relevant atomic masses by measuring the cyclotron frequency of single trapped ions in comparison to that of a single carbon ion. In this paper the measurement concept and the first doubly compensated cylindrical electrode Penning trap, are presented. Moreover, the analysis of the first measurement campaigns of the proton's and oxygen's atomic mass is described in detail, resulting in mp = 1.007 276 466 598 (33) u and m(16O)= 15.994 914 619 37 (87) u. The results on these data sets have already been presented in [F. Heisse et al., Phys. Rev. Lett. 119, 033001 (2017)]. For the proton's atomic mass, the uncertainty was improved by a factor of three compared to the 2014 CODATA value.

preprint2016arXiv

Direct mass measurements of neutron-rich 86^{86}Kr projectile fragments and the persistence of neutron magic number NN = 32 in Sc isotopes

In this paper, we present direct mass measurements of neutron-rich 86^{86}Kr projectile fragments conducted at the HIRFL-CSR facility in Lanzhou by employing the Isochronous Mass Spectrometry (IMS) method. The new mass excesses of 52−54^{52-54}Sc nuclides are determined to be -40492(82), -38928(114), -34654(540) keV, which show a significant increase of binding energy compared to the reported ones in the Atomic Mass Evaluation 2012 (AME12). In particular, 53^{53}Sc and 54^{54}Sc are more bound by 0.8 MeV and 1.0 MeV, respectively. The behavior of the two neutron separation energy with neutron numbers indicates a strong sub-shell closure at neutron number NN = 32 in Sc isotopes.

preprint2016arXiv

The Cryogenic Storage Ring CSR

An electrostatic cryogenic storage ring, CSR, for beams of anions and cations with up to 300 keV kinetic energy per unit charge has been designed, constructed and put into operation. With a circumference of 35 m, the ion-beam vacuum chambers and all beam optics are in a cryostat and cooled by a closed-cycle liquid helium system. At temperatures as low as (5.5 ±\pm 1) K inside the ring, storage time constants of several minutes up to almost an hour were observed for atomic and molecular, anion and cation beams at an energy of 60 keV. The ion-beam intensity, energy-dependent closed-orbit shifts (dispersion) and the focusing properties of the machine were studied by a system of capacitive pickups. The Schottky-noise spectrum of the stored ions revealed a broadening of the momentum distribution on a time scale of 1000 s. Photodetachment of stored anions was used in the beam lifetime measurements. The detachment rate by anion collisions with residual-gas molecules was found to be extremely low. A residual-gas density below 140 cm−3^{-3} is derived, equivalent to a room-temperature pressure below 10−14^{-14} mbar. Fast atomic, molecular and cluster ion beams stored for long periods of time in a cryogenic environment will allow experiments on collision- and radiation-induced fragmentation processes of ions in known internal quantum states with merged and crossed photon and particle beams.

preprint2016arXiv

The electron mass from gg-factor measurements on hydrogen-like carbon 12^{12}C5+^{5+}

The electron mass in atomic mass units has been determined with a relative uncertainty of 2.8⋅10−112.8\cdot 10^{-11}, which represents a 13-fold improvement of the 2010 CODATA value. The underlying measurement principle combines a high-precision measurement of the Larmor-to-cyclotron frequency ratio on a single hydrogen-like carbon ion in a Penning trap with a corresponding very accurate gg-factor calculation. Here, we present the measurement results in detail, including a comprehensive discussion of the systematic shifts and their uncertainties. A special focus is set on the various sources of phase jitters, which are essential for the understanding of the applied line-shape model for the gg-factor resonance.

preprint2015arXiv

A reservoir trap for antiprotons

We have developed techniques to extract arbitrary fractions of antiprotons from an accumulated reservoir, and to inject them into a Penning-trap system for high-precision measurements. In our trap-system antiproton storage times > 1.08 years are estimated. The device is fail-safe against power-cuts of up to 10 hours. This makes our planned comparisons of the fundamental properties of protons and antiprotons independent from accelerator cycles, and will enable us to perform experiments during long accelerator shutdown periods when background magnetic noise is low. The demonstrated scheme has the potential to be applied in many other precision Penning trap experiments dealing with exotic particles.

preprint2015arXiv

Collinear laser spectroscopy of atomic cadmium

Hyperfine structure AA and BB factors of the atomic 5s 5p   3P2→5s 6s   3S15s\,5p\,\; ^3\rm{P}_2 \rightarrow 5s\,6s\,\; ^3\rm{S}_1 transition are determined from collinear laser spectroscopy data of 107−123^{107-123}Cd and 111m−123m^{111m-123m}Cd. Nuclear magnetic moments and electric quadrupole moments are extracted using reference dipole moments and calculated electric field gradients, respectively. The hyperfine structure anomaly for isotopes with s1/2s_{1/2} and d5/2d_{5/2} nuclear ground states and isomeric h11/2h_{11/2} states is evaluated and a linear relationship is observed for all nuclear states except s1/2s_{1/2}. This corresponds to the Moskowitz-Lombardi rule that was established in the mercury region of the nuclear chart but in the case of cadmium the slope is distinctively smaller than for mercury. In total four atomic and ionic levels were analyzed and all of them exhibit a similar behaviour. The electric field gradient for the atomic 5s 5p   3P25s\,5p\,\; ^3\mathrm{P}_2 level is derived from multi-configuration Dirac-Hartree-Fock calculations in order to evaluate the spectroscopic nuclear quadrupole moments. The results are consistent with those obtained in an ionic transition and based on a similar calculation.

preprint2015arXiv

First Measurement of the 96^{96}Ru(p,γγ)97^{97}Rh Cross Section for the p-Process with a Storage Ring

This work presents a direct measurement of the 96^{96}Ru(p,γp, γ)97^{97}Rh cross section via a novel technique using a storage ring, which opens opportunities for reaction measurements on unstable nuclei. A proof-of-principle experiment was performed at the storage ring ESR at GSI in Darmstadt, where circulating 96^{96}Ru ions interacted repeatedly with a hydrogen target. The 96^{96}Ru(p,γp, γ)97^{97}Rh cross section between 9 and 11 MeV has been determined using two independent normalization methods. As key ingredients in Hauser-Feshbach calculations, the γγ-ray strength function as well as the level density model can be pinned down with the measured (p,γp, γ) cross section. Furthermore, the proton optical potential can be optimized after the uncertainties from the γγ-ray strength function and the level density have been removed. As a result, a constrained 96^{96}Ru(p,γp, γ)97^{97}Rh reaction rate over a wide temperature range is recommended for pp-process network calculations.

preprint2015arXiv

Precision Test of Many-Body QED in the Be+^+ 2p2p Fine Structure Doublet Using Short-Lived Isotopes

Absolute transition frequencies of the 2s  2S1/2→2p  2P1/2,3/22s\; ^2{\rm S}_{1/2} \rightarrow 2p\;^2\mathrm{P}_{1/2,3/2} transitions in Be+^+ were measured for the isotopes 7,9−12^{7,9-12}Be. The fine structure splitting of the 2p2p state and its isotope dependence are extracted and compared to results of \textit{ab initio} calculations using explicitly correlated basis functions, including relativistic and quantum electrodynamics effects at the order of mα6m α^6 and mα7ln⁡αm α^7 \ln α. Accuracy has been improved in both the theory and experiment by 2 orders of magnitude, and good agreement is observed. This represents one of the most accurate tests of quantum electrodynamics for many-electron systems, being insensitive to nuclear uncertainties.

preprint2014arXiv

Classical calculation of relativistic frequency-shifts in an ideal Penning trap

The ideal Penning trap consists of a uniform magnetic field and an electrostatic quadrupole potential. In the classical low-energy limit, the three characteristic eigenfrequencies of a charged particle trapped in this configuration do not depend on the amplitudes of the three eigenmotions. No matter how accurate the experimental realization of the ideal Penning trap, its harmonicity is ultimately compromised by special relativity. Using a classical formalism of first-order perturbation theory, we calculate the relativistic frequency-shifts associated with the motional degrees of freedom for a spinless particle stored in an ideal Penning trap, and we compare the results with the simple but surprisingly accurate model of relativistic mass-increase.

preprint2014arXiv

First-order perturbative calculation of the frequency-shifts caused by static cylindrically-symmetric electric and magnetic imperfections of a Penning trap

The ideal Penning trap consists of a uniform magnetic field and an electrostatic quadrupole potential. Cylindrically-symmetric deviations thereof are parametrized by the coefficients Bn and Cn, respectively. Relativistic mass-increase aside, the three characteristic eigenfrequencies of a charged particle stored in an ideal Penning trap are independent of the three motional amplitudes. This three-fold harmonicity is a highly-coveted virtue for precision experiments that rely on the measurement of at least one eigenfrequency in order to determine fundamental properties of the stored particle, such as its mass. However, higher-order contributions to the ideal fields result in amplitude-dependent frequency-shifts. In turn, these frequency-shifts need to be understood for estimating systematic experimental errors, and eventually for correcting them by means of calibrating the imperfections. The problem of calculating the frequency-shifts caused by small imperfections of a near-ideal trap yields nicely to perturbation theory, producing analytic formulas that are easy to evaluate for the relevant parameters of an experiment. In particular, the frequency-shifts can be understood on physical rather than purely mathematical grounds by considering which terms actually drive them. Based on identifying these terms, we derive general formulas for the first-order frequency-shifts caused by any perturbation parameter Bn or Cn.

preprint2014arXiv

g factor of lithiumlike silicon 28Si11+

The g factor of lithiumlike 28Si11+ has been measured in a triple-Penning trap with a relative uncertainty of 1.1x10^{-9} to be g_exp=2.0008898899(21). The theoretical prediction for this value was calculated to be g_th=2.000889909(51) improving the accuracy to 2.5x10^{-8} due to the first rigorous evaluation of the two-photon exchange correction. The measured value is in excellent agreement with the state-of-the-art theoretical prediction and yields the most stringent test of bound-state QED for the g factor of the 1s^22s state and the relativistic many-electron calculations in a magnetic field.

preprint2014arXiv

High-precision measurement of the atomic mass of the electron

The quest for the value of the electron's atomic mass has been subject of continuing efforts over the last decades. Among the seemingly fundamental constants which parameterize the Standard Model (SM) of physics and which are thus responsible for its predictive power, the electron mass me plays a prominent role, as it is responsible for the structure and properties of atoms and molecules. This manifests in the close link with other fundamental constants, such as the Rydberg constant and the fine-structure constant α. However, the low mass of the electron considerably complicates its precise determination. In this work we present a substantial improvement by combining a very accurate measurement of the magnetic moment of a single electron bound to a carbon nucleus with a state-of-the-art calculation in the framework of bound-state Quantum Electrodynamics. The achieved precision of the atomic mass of the electron surpasses the current CODATA value by a factor of 13. Accordingly, the result presented in this letter lays the foundation for future fundamental physics experiments and precision tests of the SM.

preprint2012arXiv

Nuclear Charge Radius of 12^{12}Be

The nuclear charge radius of 12^{12}Be was precisely determined using the technique of collinear laser spectroscopy on the 2s1/2→2p1/2,3/22s_{1/2}\rightarrow 2p_{1/2, 3/2} transition in the Be+^{+} ion. The mean square charge radius increases from 10^{10}Be to 12^{12}Be by $δ<r_{\rm c}^2>^{10,12} = 0.69(5) \fm^{2}$ compared to $δ<r_{\rm c}^2>^{10,11} = 0.49(5) \fm^{2}$ for the one-neutron halo isotope 11^{11}Be. Calculations in the fermionic molecular dynamics approach show a strong sensitivity of the charge radius to the structure of 12^{12}Be. The experimental charge radius is consistent with a breakdown of the N=8 shell closure.

preprint2012arXiv

Precision Atomic Physics Techniques for Nuclear Physics with Radioactive Beams

Atomic physics techniques for the determination of ground-state properties of radioactive isotopes are very sensitive and provide accurate masses, binding energies, Q-values, charge radii, spins, and electromagnetic moments. Many fields in nuclear physics benefit from these highly accurate numbers. They give insight into details of the nuclear structure for a better understanding of the underlying effective interactions, provide important input for studies of fundamental symmetries in physics, and help to understand the nucleosynthesis processes that are responsible for the observed chemical abundances in the Universe. Penning-trap and and storage-ring mass spectrometry as well as laser spectroscopy of radioactive nuclei have now been used for a long time but significant progress has been achieved in these fields within the last decade. The basic principles of laser spectroscopic investigations, Penning-trap and storage-ring mass measurements of short-lived nuclei are summarized and selected physics results are discussed.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.