Source author record

Wolfgang Quint

Wolfgang Quint appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

9works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

9 published item(s)

preprint2022arXiv

Penning-trap mass measurements of the deuteron and the HD+ molecular ion

The masses of the lightest atomic nuclei and the electron mass are interlinked and are crucial in a wide range of research fields, with their values affecting observables in atomic, molecular and neutrino physics as well as metrology. The most precise values for these fundamental parameters come from Penning-trap mass spectrometry, which achieves relative mass uncertainties in the range of $10^{-11}$. However, redundancy checks using data from different experiments reveal significant inconsistencies in the masses of the proton ($m_p$), the deuteron ($m_d$) and helion ($m_\text{he}$), amounting to $5$ standard deviations for the term $Δ=m_p+m_d-m_{\text{he}}$, which suggests that the uncertainty of these values may have been underestimated. Here we present results from absolute mass measurements of the deuteron and the ${HD}^+$ molecular ion against $^{12}C$ as a mass reference. Our value for the deuteron $m_d=2.013\,553\,212\,535 (17)$u supersedes the precision of the literature value by a factor of $2.4$ and deviates from this by $4.8$ standard deviations. With a relative uncertainty of $8$ parts per trillion (ppt) this is the most precise mass value measured directly in atomic mass units. Furthermore, the measurement of the ${HD}^+$ molecular ion, $m({HD}^+)=3.021\,378\,241\,561\,(61)$u, not only allows for a rigorous consistency check of our measurements of the masses of the deuteron (this work) and proton, but also establishes an additional link for the masses of tritium and helium-3 to the atomic mass unit. Combined with a recent measurement of the deuteron-to-proton mass ratio the uncertainty of the reference value of $m_p$ can be reduced by a factor of three. This is a post-peer-review, pre-copyedit version of an article published in Nature. The final authenticated version is available online at https://doi.org/10.1038/s41586-020-2628-7

preprint2021arXiv

Constraints on the Coupling between Axionlike Dark Matter and Photons Using an Antiproton Superconducting Tuned Detection Circuit in a Cryogenic Penning Trap

We constrain the coupling between axionlike particles (ALPs) and photons, measured with the superconducting resonant detection circuit of a cryogenic Penning trap. By searching the noise spectrum of our fixed-frequency resonant circuit for peaks caused by dark matter ALPs converting into photons in the strong magnetic field of the Penning-trap magnet, we are able to constrain the coupling of ALPs with masses around $2.7906-2.7914\,\textrm{neV/c}^2$ to $g_{aγ}< 1 \times 10^{-11}\,\textrm{GeV}^{-1}$. This is more than one order of magnitude lower than the best laboratory haloscope and approximately 5 times lower than the CERN axion solar telescope (CAST), setting limits in a mass and coupling range which is not constrained by astrophysical observations. Our approach can be extended to many other Penning-trap experiments and has the potential to provide broad limits in the low ALP mass range.

preprint2020arXiv

High-precision mass spectrometer for light ions

The precise knowledge of the atomic masses of light atomic nuclei, e.g. the proton, deuteron, triton and helion, is of great importance for several fundamental tests in physics. However, the latest high-precision measurements of these masses carried out at different mass spectrometers indicate an inconsistency of five standard deviations. To determine the masses of the lightest ions with a relative precision of a few parts per trillion and investigate this mass problem a cryogenic multi-Penning trap setup, LIONTRAP (Light ION TRAP), was constructed. This allows an independent and more precise determination of the relevant atomic masses by measuring the cyclotron frequency of single trapped ions in comparison to that of a single carbon ion. In this paper the measurement concept and the first doubly compensated cylindrical electrode Penning trap, are presented. Moreover, the analysis of the first measurement campaigns of the proton's and oxygen's atomic mass is described in detail, resulting in mp = 1.007 276 466 598 (33) u and m(16O)= 15.994 914 619 37 (87) u. The results on these data sets have already been presented in [F. Heisse et al., Phys. Rev. Lett. 119, 033001 (2017)]. For the proton's atomic mass, the uncertainty was improved by a factor of three compared to the 2014 CODATA value.

preprint2016arXiv

The electron mass from $g$-factor measurements on hydrogen-like carbon $^{12}$C$^{5+}$

The electron mass in atomic mass units has been determined with a relative uncertainty of $2.8\cdot 10^{-11}$, which represents a 13-fold improvement of the 2010 CODATA value. The underlying measurement principle combines a high-precision measurement of the Larmor-to-cyclotron frequency ratio on a single hydrogen-like carbon ion in a Penning trap with a corresponding very accurate $g$-factor calculation. Here, we present the measurement results in detail, including a comprehensive discussion of the systematic shifts and their uncertainties. A special focus is set on the various sources of phase jitters, which are essential for the understanding of the applied line-shape model for the $g$-factor resonance.

preprint2015arXiv

A reservoir trap for antiprotons

We have developed techniques to extract arbitrary fractions of antiprotons from an accumulated reservoir, and to inject them into a Penning-trap system for high-precision measurements. In our trap-system antiproton storage times > 1.08 years are estimated. The device is fail-safe against power-cuts of up to 10 hours. This makes our planned comparisons of the fundamental properties of protons and antiprotons independent from accelerator cycles, and will enable us to perform experiments during long accelerator shutdown periods when background magnetic noise is low. The demonstrated scheme has the potential to be applied in many other precision Penning trap experiments dealing with exotic particles.

preprint2014arXiv

g factor of lithiumlike silicon 28Si11+

The g factor of lithiumlike 28Si11+ has been measured in a triple-Penning trap with a relative uncertainty of 1.1x10^{-9} to be g_exp=2.0008898899(21). The theoretical prediction for this value was calculated to be g_th=2.000889909(51) improving the accuracy to 2.5x10^{-8} due to the first rigorous evaluation of the two-photon exchange correction. The measured value is in excellent agreement with the state-of-the-art theoretical prediction and yields the most stringent test of bound-state QED for the g factor of the 1s^22s state and the relativistic many-electron calculations in a magnetic field.

preprint2014arXiv

Half-open Penning trap with efficient light collection for precision laser spectroscopy of highly charged ions

We have conceived, built and operated a 'half-open' cylindrical Penning trap for the confinement and laser spectroscopy of highly charged ions. This trap allows fluorescence detection employing a solid angle which is about one order of magnitude larger than in conventional cylindrical Penning traps. At the same time, the desired electrostatic and magnetostatic properties of a closed-endcap cylindrical Penning trap are preserved in this congfiuration. We give a detailed account on the design and confinement properties, a characterization of the trap and show first results of light collection with in-trap produced highly charged ions.

preprint2014arXiv

High-precision measurement of the atomic mass of the electron

The quest for the value of the electron's atomic mass has been subject of continuing efforts over the last decades. Among the seemingly fundamental constants which parameterize the Standard Model (SM) of physics and which are thus responsible for its predictive power, the electron mass me plays a prominent role, as it is responsible for the structure and properties of atoms and molecules. This manifests in the close link with other fundamental constants, such as the Rydberg constant and the fine-structure constant α. However, the low mass of the electron considerably complicates its precise determination. In this work we present a substantial improvement by combining a very accurate measurement of the magnetic moment of a single electron bound to a carbon nucleus with a state-of-the-art calculation in the framework of bound-state Quantum Electrodynamics. The achieved precision of the atomic mass of the electron surpasses the current CODATA value by a factor of 13. Accordingly, the result presented in this letter lays the foundation for future fundamental physics experiments and precision tests of the SM.

preprint2014arXiv

Switchable Magnetic Bottles and Field Gradients for Particle Traps

Versatile methods for the manipulation of individual quantum systems, such as confined particles, have become central elements in current developments in precision spectroscopy, frequency standards, quantum information processing, quantum simulation, and alike. For atomic and some subatomic particles, both neutral and charged, a precise control of magnetic fields is essen- tial. In this paper, we discuss possibilities for the creation of specific magnetic field configurations which find appli- cation in these areas. In particular, we pursue the idea of a magnetic bottle which can be switched on and off by transition between the normal and the superconducting phase of a suitable material in cryogenic environments, for example in trap experiments in moderate magnetic fields. Methods for a fine-tuning of the magnetic field and its linear and quadratic components in a trap are presented together with possible applications.