Source author record

Jianfeng Zhou

Jianfeng Zhou appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

10works
11topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

10 published item(s)

preprint2022arXiv

A Direct Slip Ratio Estimation Method based on an Intelligent Tire and Machine Learning

Accurate estimation of the tire slip ratio is critical for vehicle safety, as it is necessary for vehicle control purposes. In this paper, an intelligent tire system is presented to develop a novel slip ratio estimation model using machine learning algorithms. The accelerations, generated by a triaxial accelerometer installed onto the inner liner of the tire, are varied when the tire rotates to update the contact patch. Meanwhile, the slip ratio reference value can be measured by the MTS Flat-Trac tire test platform. Then, by analyzing the variation between the accelerations and slip ratio, highly useful features are discovered, which are especially promising for assessing vertical acceleration. For these features, machine learning (ML) algorithms are trained to build the slip ratio estimation model, in which the ML algorithms include artificial neural networks (ANNs), gradient boosting machines (GBMs), random forests (RFs), and support vector machines (SVMs). Finally, the estimated NRMS errors are evaluated using 10-fold cross-validation (CV). The proposed estimation model is able to estimate the slip ratio continuously and stably using only the acceleration from the intelligent tire system, and the estimated slip ratio range can reach 30%. The estimation results have high robustness to vehicle velocity and load, where the best NRMS errors can reach 4.88%. In summary, the present study with the fusion of an intelligent tire system and machine learning paves the way for the accurate estimation of the tire slip ratio under different driving conditions, which create new opportunities for autonomous vehicles, intelligent tires, and tire slip ratio estimation.

preprint2022arXiv

Correction Algorithm of Sampling Effect and Its Application

The sampling effect of the imaging acquisition device is long considered to be a modulation process of the input signal, introducing additional error into the signal acquisition process. This paper proposes a correction algorithm for the modulation process that solves the sampling effect with high accuracy. We examine the algorithm with perfect continuous Gaussian images and selected digitized images, which indicate an accuracy increase of 106 for Gaussian images, 102 at 15 times of Shannon interpolation for digitized images, and 105 at 101 times of Shannon interpolation for digitized images. The accuracy limit of the Gaussian image comes from the truncation error, while the accuracy limit of the digitized images comes from their finite resolution, which can be improved by increasing the time of Shannon interpolation.

preprint2022arXiv

Field Distortion Model Based on Fredholm Integral

Field distortion is widespread in imaging systems. If it cannot be measured and corrected well, it will affect the accuracy of photogrammetry. To this end, we proposed a general field distortion model based on Fredholm integration, which uses a reconstructed high-resolution reference point spread function (PSF) and two sets of 4-variable polynomials to describe an imaging system. The model includes the point-to-point positional distortion from the object space to the image space and the deformation of the PSF so that we can measure an actual field distortion with arbitrary accuracy. We also derived the formula required for correcting the sampling effect of the image sensor. Through numerical simulation, we verify the effectiveness of the model and reconstruction algorithm. This model will have potential application in high-precision image calibration, photogrammetry and astrometry.

preprint2020arXiv

A Statistical Model for Imaging Systems

The behavior of photons is controlled by quantum mechanics, not as deterministic as classical optics shows. To this end, we defined a new statistic $Z$, which is equal to the variance minus the expectation or mean. Then, we established a statistical model for imaging systems and obtained three fundamental imaging formulas. Among them, the first formula is entirely consistent with the classic convolution equation. The second and third ones link the $Z$ quantities of the object and noise elegantly with the $Z$ image and covariance image, revealing new laws. Consequently, besides the flux density, the $Z$ quantity of an object is also imageable, which opens a new realm for imaging systems to explore the physical world.

preprint2015arXiv

Point source detection performance of Hard X-ray Modulation Telescope imaging observation

The Hard X-ray Modulation Telescope (HXMT) will perform an all-sky survey in hard X-ray band as well as deep imaging of a series of small sky regions. We expect various compact objects to be detected in these imaging observations. Point source detection performance of HXMT imaging observation depends not only on the instrument but also on its data analysis since images are reconstructed from HXMT observed data with numeric methods. Denoising technique plays an import part in HXMT imaging data analysis pipeline alongside with demodulation and source detection. In this paper we have implemented several methods for denoising HXMT data and evaluated the point source detection performances in terms of sensitivities and location accuracies. The results show that direct demodulation with 1-fold cross correlation should be the default reconstruction and regularization methods, although both sensitivity and location accuracy could be further imporved by selecting and tuning numerical methods in data analysis of HXMT imaging observations.

preprint2014arXiv

Transformed Auto-correlation

A transformed auto-correlation method is presented here, where a received signal is transformed based on a priori reflecting model, and then the transformed signal is cross-correlated to its original one. If the model is correct, after transformation, the reflected signal will be coherent to the transmitted signal, with zero delay. A map of transformed auto-correlation function with zero delay can be generated in a given parametric space. The significant peaks in the map may indicate the possible reflectors nearby the central transmitter. The true values of the parameters of reflectors can be estimated at the same time.

preprint2010arXiv

Calibrating the atomic balance by carbon nanoclusters

Carbon atoms are counted at near atomic-level precision using a scanning transmission electron microscope calibrated by carbon nanocluster mass standards. A linear calibration curve governs the working zone from a few carbon atoms up to 34,000 atoms. This linearity enables adequate averaging of the scattering cross sections, imparting the experiment with near atomic-level precision despite the use of a coarse mass reference. An example of this approach is provided for thin layers of stacked graphene sheets. Suspended sheets with a thickness below 100 nm are visualized, providing quantitative measurement in a regime inaccessible to optical and scanning probe methods.

preprint2010arXiv

Films with the discrete nano-DLC-particles as the field emission cascade

The films with the discrete diamond-like-carbon nanoparticles were prepared by the deposition of the carbon nanoparticle beam. Their morphologies were imaged by Scanning Electron Microscopy (SEM) and Atomic Force Microscopy (AFM). The nanoparticles were found distributed on the silicon (100) substrate discretely. The semisphere shapes of the nanoparticles were demonstrated by the AFM line profile. EELS was measured and the sp3 ratio as high as 86% was found. The field-induced electron emission of the as-prepared cascade (nanoDLC/ Si) was tested and the current density of 1mA/cm2 was achieved at 10.2V/μm.

preprint2010arXiv

Two-step splitting the expandable graphite for few-layer graphene

Few-layer graphene sheets are prepared by splitting the expanded graphites using a high-power sonication. Atomic-level quantitative scanning transmission electron microscopy (Q-STEM) is employed to carry out the efficient layer statisticsm, enabling global optimization of the experimental conditions. A two-step splitting mechanism is thus revealed, in which the mean layer number was firstly reduced to less than 20 by heating to 1100°C and then tuned to the few-layer region by a 5-minute 104W/litre sonication. Raman spectroscopic analysis confirms the above mechanism and demonstrates that the sheets are largely free of defects and oxides.

preprint2006arXiv

Doppler Boosting and Deboosting Effects in the Forward Relativistic Jets of AGNs and GRBs

It is widely accepted that the Doppler deboosting effects exist in counter relativistic jets. However, people often neglect another important fact that both Doppler boosting and deboosting effects could happen in forward relativistic jets. Such effects might be used to explain some strange phenomena, such as the invisible gaps between the inner and outer jets of AGNs, and the rapid initial decays and re-brightening bumps in the light curves of GRBs.