Source author record

Hidetoshi Katori

Hidetoshi Katori appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

13works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

13 published item(s)

preprint2020arXiv

Superradiance from Lattice-Confined Atoms inside Hollow Core Fibre

Unravelling superradiance, also known as superfluorescence, relies on an ensemble of phase-matched dipole oscillators and the suppression of inhomogeneous broadening. Here we report on a novel superradiance platform that combines an optical lattice free from the ac Stark shift and a hollow-core photonic crystal fibre, enabling an extended atom-light interaction over $2 \mathrm{mm}$ free from the Doppler effect. This system allows controlling the atom spatial distribution and spectral homogeneity whilst efficiently coupling the radiation field to an optical fibre. The experimentally-observed and theoretically-corroborated temporal, spectral and spatial dynamic behaviours of the superradiance, e.g., superradiance ringing and density-dependent frequency shift, demonstrate a unique interplay between the trapped atoms and the fibre-guided field with multiple transverse modes. Our theory indicates the resulting temporal evolution of the guided light shows a minimal beam radius of $3.1 \mathrm{μm}$ that is three times smaller than that of the lowest-loss fibre mode.

preprint2016arXiv

Continuous-wave, single-frequency 229 nm laser source for laser cooling of cadmium atoms

Continuous-wave output at 229 nm for the application of laser cooling of Cd atoms was generated by the 4th harmonic using two successive second harmonic generation stages. Employing a single-frequency optically pumped semiconductor laser as a fundamental source, 0.56 W of output at 229 nm was observed with a 10-mm long, Brewster-cut BBO crystal in an external cavity with 1.62 W of 458 nm input. Conversion efficiency from 458 nm to 229 nm was more than 34%. By applying a tapered amplifier as a fundamental source, we demonstrated magneto-optical trapping of all stable Cd isotopes including isotopes $^{111}$Cd and $^{113}$Cd, which are applicable to optical lattice clocks.

preprint2016arXiv

Frequency ratio of Yb and Sr clocks with $5 \times 10^{-17}$ uncertainty at 150 s averaging time

Transition frequencies of atoms and ions are among the most accurately accessible quantities in nature, playing important roles in pushing the frontiers of science by testing fundamental laws of physics, in addition to a wide range of applications such as satellite navigation systems. Atomic clocks based on optical transitions approach uncertainties of $10^{-18}$, where full frequency descriptions are far beyond the reach of the SI second. Frequency ratios of such super clocks, on the other hand, are not subject to this limitation. They can therefore verify consistency and overall accuracy for an ensemble of super clocks, an essential step towards a redefinition of the second. However, with the measurement stabilities so far reported for such frequency ratios, a confirmation to $1 \times 10^{-18}$ uncertainty would require an averaging time $τ$ of multiple months. Here we report a measurement of the frequency ratio of neutral ytterbium and strontium clocks with a much improved stability of $4 \times 10^{-16} (τ/s)^{-1/2}$. Enabled by the high stability of optical lattice clocks interrogating hundreds of atoms, this marks a 90-fold reduction in the required averaging time over a previous record-setting experiment that determined the ratio of Al+ and Hg+ single-ion clocks to an uncertainty of $5.2 \times 10^{-17}$. For the Yb/Sr ratio, we find R = 1.207 507 039 343 337 749(55), with a fractional uncertainty of $4.6 \times 10^{-17}$.

preprint2016arXiv

Real-time geopotentiometry with synchronously linked optical lattice clocks

According to the Einstein's theory of relativity, the passage of time changes in a gravitational field. On earth, raising a clock by one centimetre increases its tick rate by 1.1 parts in 10$^{18}$, enabling optical clocks to perform precision geodesy. Here, we demonstrate geopotentiometry by determining the height difference of master and slave clocks separated by 15 km with uncertainty of 5 cm. The subharmonic of the master clock is delivered through a telecom fibre to phase-lock and synchronously interrogate the slave clock. This protocol rejects laser noise in the comparison of two clocks, which improves the stability of measuring the gravitational red shift. Such phase-coherently operated clocks facilitate proposals for linking clocks and interferometers. Over half a year, 11 measurements determine the fractional frequency difference between the two clocks to be $1,652.9(5.9)\times 10^{-18}$, or a height difference of 1,516(5) cm, consistent with an independent measurement by levelling and gravimetry. Our system is as a building block of an internet of clocks, consisting of a master and a number of slave clocks, which will provide "quantum benchmarks" that are height references with dynamic response.

preprint2015arXiv

Compact FPGA-based pulse-sequencer and radio-frequency generator for experiments with trapped atoms

We present a compact FPGA-based pulse sequencer and radio-frequency (RF) generator suitable for experiments with cold trapped ions and atoms. The unit is capable of outputting a pulse sequence with at least 32 TTL channels with a timing resolution of 40 ns and contains a built-in 100 MHz frequency counter for counting electrical pulses from a photo-multiplier tube (PMT). There are 16 independent direct-digital-synthesizers (DDS) RF sources with fast (rise-time of ~60 ns) amplitude switching and sub-mHz frequency tuning from 0 to 800 MHz.

preprint2015arXiv

Frequency Ratio of ${}^{199}$Hg and ${}^{87}$Sr Optical Lattice Clocks beyond the SI Limit

We report on a frequency ratio measurement of a ${}^{199}$Hg-based optical lattice clock referencing a ${}^{87}$Sr-based clock. Evaluations of lattice light shift, including atomic-motion-dependent shift, enable us to achieve a total systematic uncertainty of $7.2 \times 10^{-17}$ for the Hg clock. The frequency ratio is measured to be $ν_{\rm Hg}/ν_{\rm Sr}=2.629\, 314\, 209\, 898\, 909\, 60(22)$ with a fractional uncertainty of $8.4 \times 10^{-17}$, which is smaller than the uncertainty of the realization of the SI second, i.e., the SI limit.

preprint2015arXiv

Frequency ratios of Sr, Yb and Hg based optical lattice clocks and their applications

This article describes the recent progress of optical lattice clocks with neutral strontium ($^{87}$Sr), ytterbium ($^{171}$Yb) and mercury ($^{199}$Hg) atoms. In particular, we present frequency comparison between the clocks locally via an optical frequency comb and between two Sr clocks at remote sites using a phase-stabilized fibre link. We first review cryogenic Sr optical lattice clocks that reduce the room-temperature blackbody radiation shift by two orders of magnitude and serve as a reference in the following clock comparisons. Similar physical properties of Sr and Yb atoms, such as transition wavelengths and vapour pressure, have allowed our development of a compatible clock for both species. A cryogenic Yb clock is evaluated by referencing a Sr clock. We also report on a Hg clock, which shows one order of magnitude less sensitivity to blackbody radiation, while its large nuclear charge makes the clock sensitive to the variation of fine-structure constant. Connecting all three types of clocks by an optical frequency comb, the ratios of the clock frequencies are determined with uncertainties smaller than possible through absolute frequency measurements. Finally, we describe a synchronous frequency comparison between two Sr-based remote clocks over a distance of 15 km between RIKEN and the University of Tokyo, as a step towards relativistic geodesy.

preprint2015arXiv

Strategies for reducing the light shift in atomic clocks

Recent progress in optical lattice clocks requires unprecedented precision in controlling systematic uncertainties at $10^{-18}$ level. Tuning of nonlinear light shifts is shown to reduce lattice-induced clock shift for wide range of lattice intensity. Based on theoretical multipolar, nonlinear, anharmonic and higher-order light shifts, we numerically demonstrate possible strategies for Sr, Yb, and Hg clocks to achieve lattice-induced systematic uncertainty below $1\times 10^{-18}$.

preprint2014arXiv

Cryogenic optical lattice clocks with a relative frequency difference of $1\times 10^{-18}$

Time and frequency are the most accurately measurable quantities, providing foundations for science and modern technologies. The accuracy relies on the SI (Systéme International) second that refers to Cs microwave clocks with fractional uncertainties at $10^{-16}$. Recent revolutionary progress of optical clocks aims to achieve $1\times 10^{-18}$ uncertainty, which however has been hindered by long averaging-times or by systematic uncertainties. Here, we demonstrate optical lattice clocks with $^{87}$Sr atoms interrogated in a cryogenic environment to address the blackbody radiation-induced frequency-shift, which remains the primary source of clocks' uncertainties and has initiated vigorous theoretical and experimental investigations. The quantum-limited stability for $N \sim 1,000$ atoms allows investigation of the uncertainties at $2\times 10^{-18}$ in two hours of clock operation. After 11 measurements performed over a month, the two cryo-clocks agree to within $(-1.1\pm 1.6)\times 10^{-18}$. Besides its contribution to fundamental science and the redefinition of the SI second, such a speedy comparison of accurate clocks provides a means for relativistic geodesy.

preprint2014arXiv

Lamb-Dicke spectroscopy of atoms in a hollow-core photonic crystal fibre

Unlike photons, which are conveniently handled by mirrors and optical fibres without loss of coherence, atoms lose their coherence via atom-atom and atom-wall interactions. This decoherence of atoms deteriorates the performance of atomic clocks and magnetometers, and also hinders their miniaturisation. Here we report a novel platform for precision spectroscopy. Ultracold strontium atoms inside a kKagome-lattice hollow-core photonic crystal fibre (HC-PCF) are transversely confined by an optical lattice to prevent atoms from interacting with the fibre wall. By confining at most one atom in each lattice site, to avoid atom-atom interactions and Doppler effect, a 7.8-kHz-wide spectrum is observed for the $^1 S_0-{}^3P_1$ (m=0) transition. Atoms singly trapped in a magic lattice in hollow-core photonic crystal fibresHC-PCFs improve the optical depth while preserving atomic coherence time.

preprint2014arXiv

Optical clock sensitive to variation of the fine structure constant based on the Ho$^{14+}$ ion

We study the Ho$^{14+}$ ion as a candidate for extremely accurate and stable optical atomic clock which is sensitive to the time variation of the fine structure constant. We demonstrate that the proposed system has all desired features including relatively strong optical electric dipole and magnetic dipole transitions which can be used for cooling and detection. Zero quadrupole moments for the relevant states in the clock transition allows interrogating multiple ions to improve the clock stability.

preprint2011arXiv

Direct Comparison of Distant Optical Lattice Clocks at the $10^{-16}$ Uncertainty

Fiber-based remote comparison of $^{87}$Sr lattice clocks in 24 km distant laboratories is demonstrated. The instability of the comparison reaches $5\times10^{-16}$ over an averaging time of 1000 s, which is two orders of magnitude shorter than that of conventional satellite links and is limited by the instabilities of the optical clocks. By correcting the systematic shifts that are predominated by the differential gravitational redshift, the residual fractional difference is found to be $(1.0\pm7.3)\times10^{-16}$, confirming the coincidence between the two clocks. The accurate and speedy comparison of distant optical clocks paves the way for a future optical redefinition of the second.

preprint2010arXiv

Colloquium: Physics of optical lattice clocks

Recently invented and demonstrated, optical lattice clocks hold great promise for improving the precision of modern timekeeping. These clocks aim at the 10^-18 fractional accuracy, which translates into a clock that would neither lose or gain a fraction of a second over an estimated age of the Universe. In these clocks, millions of atoms are trapped and interrogated simultaneously, dramatically improving clock stability. Here we discuss the principles of operation of these clocks and, in particular, a novel concept of "magic" trapping of atoms in optical lattices. We also highlight recently proposed microwave lattice clocks and several applications that employ the optical lattice clocks as a platform for precision measurements and quantum information processing.