Researcher profile

Atsushi Yamaguchi

Atsushi Yamaguchi contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
6works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2020arXiv

On the growth of topological complexity

Let $\mathrm{TC}_r(X)$ denote the $r$-th topological complexity of a space $X$. In many cases, the generating function $\sum_{r\ge 1}\mathrm{TC}_{r+1}(X)x^r$ is a rational function $\frac{P(x)}{(1-x)^2}$ where $P(x)$ is a polynomial with $P(1)=\mathrm{cat}(X)$, that is, the asymptotic growth of $\mathrm{TC}_r(X)$ with respect to $r$ is $\mathrm{cat}(X)$. In this paper, we introduce a lower bound $\mathrm{MTC}_r(X)$ of $\mathrm{TC}_r(X)$ for a rational space $X$, and estimate the growth of $\mathrm{MTC}_r(X)$.

preprint2016arXiv

Continuous-wave, single-frequency 229 nm laser source for laser cooling of cadmium atoms

Continuous-wave output at 229 nm for the application of laser cooling of Cd atoms was generated by the 4th harmonic using two successive second harmonic generation stages. Employing a single-frequency optically pumped semiconductor laser as a fundamental source, 0.56 W of output at 229 nm was observed with a 10-mm long, Brewster-cut BBO crystal in an external cavity with 1.62 W of 458 nm input. Conversion efficiency from 458 nm to 229 nm was more than 34%. By applying a tapered amplifier as a fundamental source, we demonstrated magneto-optical trapping of all stable Cd isotopes including isotopes $^{111}$Cd and $^{113}$Cd, which are applicable to optical lattice clocks.

preprint2015arXiv

Frequency ratios of Sr, Yb and Hg based optical lattice clocks and their applications

This article describes the recent progress of optical lattice clocks with neutral strontium ($^{87}$Sr), ytterbium ($^{171}$Yb) and mercury ($^{199}$Hg) atoms. In particular, we present frequency comparison between the clocks locally via an optical frequency comb and between two Sr clocks at remote sites using a phase-stabilized fibre link. We first review cryogenic Sr optical lattice clocks that reduce the room-temperature blackbody radiation shift by two orders of magnitude and serve as a reference in the following clock comparisons. Similar physical properties of Sr and Yb atoms, such as transition wavelengths and vapour pressure, have allowed our development of a compatible clock for both species. A cryogenic Yb clock is evaluated by referencing a Sr clock. We also report on a Hg clock, which shows one order of magnitude less sensitivity to blackbody radiation, while its large nuclear charge makes the clock sensitive to the variation of fine-structure constant. Connecting all three types of clocks by an optical frequency comb, the ratios of the clock frequencies are determined with uncertainties smaller than possible through absolute frequency measurements. Finally, we describe a synchronous frequency comparison between two Sr-based remote clocks over a distance of 15 km between RIKEN and the University of Tokyo, as a step towards relativistic geodesy.

preprint2011arXiv

All-optical link for direct comparison of distant optical clocks

We developed an all-optical link system for making remote comparisons of two distant ultra-stable optical clocks. An optical carrier transfer system based on a fiber interferometer was employed to compensate the phase noise accumulated during the propagation through a fiber link. Transfer stabilities of $2\times10^{-15}$ at 1 second and $4\times10^{-18}$ at 1000 seconds were achieved in a 90-km link. An active polarization control system was additionally introduced to maintain the transmitted light in an adequate polarization, and consequently, a stable and reliable comparison was accomplished. The instabilities of the all-optical link system, including those of the erbium doped fiber amplifiers (EDFAs) which are free from phase-noise compensation, were below $2\times10^{-15}$ at 1 second and $7\times10^{-17}$ at 1000 seconds. The system was available for the direct comparison of two distant $^{87}$Sr lattice clocks via an urban fiber link of 60 km. This technique will be essential for the measuring the reproducibility of optical frequency standards.

preprint2011arXiv

Direct Comparison of Distant Optical Lattice Clocks at the $10^{-16}$ Uncertainty

Fiber-based remote comparison of $^{87}$Sr lattice clocks in 24 km distant laboratories is demonstrated. The instability of the comparison reaches $5\times10^{-16}$ over an averaging time of 1000 s, which is two orders of magnitude shorter than that of conventional satellite links and is limited by the instabilities of the optical clocks. By correcting the systematic shifts that are predominated by the differential gravitational redshift, the residual fractional difference is found to be $(1.0\pm7.3)\times10^{-16}$, confirming the coincidence between the two clocks. The accurate and speedy comparison of distant optical clocks paves the way for a future optical redefinition of the second.

preprint2007arXiv

Monte Carlo approach to nonperturbative strings -- demonstration in noncritical string theory

We show how Monte Carlo approach can be used to study the double scaling limit in matrix models. As an example, we study a solvable hermitian one-matrix model with the double-well potential, which has been identified recently as a dual description of noncritical string theory with worldsheet supersymmetry. This identification utilizes the nonperturbatively stable vacuum unlike its bosonic counterparts, and therefore it provides a complete constructive formulation of string theory. Our data with the matrix size ranging from 8 to 512 show a clear scaling behavior, which enables us to extract the double scaling limit accurately. The ``specific heat'' obtained in this way agrees nicely with the known result obtained by solving the Painleve-II equation with appropriate boundary conditions.