Researcher profile

Noriaki Ohmae

Noriaki Ohmae contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
7works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2016arXiv

Continuous-wave, single-frequency 229 nm laser source for laser cooling of cadmium atoms

Continuous-wave output at 229 nm for the application of laser cooling of Cd atoms was generated by the 4th harmonic using two successive second harmonic generation stages. Employing a single-frequency optically pumped semiconductor laser as a fundamental source, 0.56 W of output at 229 nm was observed with a 10-mm long, Brewster-cut BBO crystal in an external cavity with 1.62 W of 458 nm input. Conversion efficiency from 458 nm to 229 nm was more than 34%. By applying a tapered amplifier as a fundamental source, we demonstrated magneto-optical trapping of all stable Cd isotopes including isotopes $^{111}$Cd and $^{113}$Cd, which are applicable to optical lattice clocks.

preprint2016arXiv

Frequency ratio of Yb and Sr clocks with $5 \times 10^{-17}$ uncertainty at 150 s averaging time

Transition frequencies of atoms and ions are among the most accurately accessible quantities in nature, playing important roles in pushing the frontiers of science by testing fundamental laws of physics, in addition to a wide range of applications such as satellite navigation systems. Atomic clocks based on optical transitions approach uncertainties of $10^{-18}$, where full frequency descriptions are far beyond the reach of the SI second. Frequency ratios of such super clocks, on the other hand, are not subject to this limitation. They can therefore verify consistency and overall accuracy for an ensemble of super clocks, an essential step towards a redefinition of the second. However, with the measurement stabilities so far reported for such frequency ratios, a confirmation to $1 \times 10^{-18}$ uncertainty would require an averaging time $τ$ of multiple months. Here we report a measurement of the frequency ratio of neutral ytterbium and strontium clocks with a much improved stability of $4 \times 10^{-16} (τ/s)^{-1/2}$. Enabled by the high stability of optical lattice clocks interrogating hundreds of atoms, this marks a 90-fold reduction in the required averaging time over a previous record-setting experiment that determined the ratio of Al+ and Hg+ single-ion clocks to an uncertainty of $5.2 \times 10^{-17}$. For the Yb/Sr ratio, we find R = 1.207 507 039 343 337 749(55), with a fractional uncertainty of $4.6 \times 10^{-17}$.

preprint2016arXiv

Higher order test of Lorentz invariance with an optical ring cavity

We have developed an apparatus to search for the higher-order Lorentz violation in photons by measuring the resonant frequency difference between two counterpropagating directions of an asymmetric optical ring cavity. From the year-long data taken between 2012 and 2013, we found no evidence for the light speed anisotropy at the level of $δc/c \lesssim 10^{-15}$. Limits on the dipole components of the anisotropy are improved by more than an order of magnitude, and limits on the hexapole components are obtained for the first time. An overview of our apparatus and the data analysis in the framework of the spherical harmonics decomposition of anisotropy are presented. We also present the status of the recent upgrade of the apparatus.

preprint2016arXiv

Real-time geopotentiometry with synchronously linked optical lattice clocks

According to the Einstein's theory of relativity, the passage of time changes in a gravitational field. On earth, raising a clock by one centimetre increases its tick rate by 1.1 parts in 10$^{18}$, enabling optical clocks to perform precision geodesy. Here, we demonstrate geopotentiometry by determining the height difference of master and slave clocks separated by 15 km with uncertainty of 5 cm. The subharmonic of the master clock is delivered through a telecom fibre to phase-lock and synchronously interrogate the slave clock. This protocol rejects laser noise in the comparison of two clocks, which improves the stability of measuring the gravitational red shift. Such phase-coherently operated clocks facilitate proposals for linking clocks and interferometers. Over half a year, 11 measurements determine the fractional frequency difference between the two clocks to be $1,652.9(5.9)\times 10^{-18}$, or a height difference of 1,516(5) cm, consistent with an independent measurement by levelling and gravimetry. Our system is as a building block of an internet of clocks, consisting of a master and a number of slave clocks, which will provide "quantum benchmarks" that are height references with dynamic response.

preprint2015arXiv

Frequency Ratio of ${}^{199}$Hg and ${}^{87}$Sr Optical Lattice Clocks beyond the SI Limit

We report on a frequency ratio measurement of a ${}^{199}$Hg-based optical lattice clock referencing a ${}^{87}$Sr-based clock. Evaluations of lattice light shift, including atomic-motion-dependent shift, enable us to achieve a total systematic uncertainty of $7.2 \times 10^{-17}$ for the Hg clock. The frequency ratio is measured to be $ν_{\rm Hg}/ν_{\rm Sr}=2.629\, 314\, 209\, 898\, 909\, 60(22)$ with a fractional uncertainty of $8.4 \times 10^{-17}$, which is smaller than the uncertainty of the realization of the SI second, i.e., the SI limit.

preprint2015arXiv

Frequency ratios of Sr, Yb and Hg based optical lattice clocks and their applications

This article describes the recent progress of optical lattice clocks with neutral strontium ($^{87}$Sr), ytterbium ($^{171}$Yb) and mercury ($^{199}$Hg) atoms. In particular, we present frequency comparison between the clocks locally via an optical frequency comb and between two Sr clocks at remote sites using a phase-stabilized fibre link. We first review cryogenic Sr optical lattice clocks that reduce the room-temperature blackbody radiation shift by two orders of magnitude and serve as a reference in the following clock comparisons. Similar physical properties of Sr and Yb atoms, such as transition wavelengths and vapour pressure, have allowed our development of a compatible clock for both species. A cryogenic Yb clock is evaluated by referencing a Sr clock. We also report on a Hg clock, which shows one order of magnitude less sensitivity to blackbody radiation, while its large nuclear charge makes the clock sensitive to the variation of fine-structure constant. Connecting all three types of clocks by an optical frequency comb, the ratios of the clock frequencies are determined with uncertainties smaller than possible through absolute frequency measurements. Finally, we describe a synchronous frequency comparison between two Sr-based remote clocks over a distance of 15 km between RIKEN and the University of Tokyo, as a step towards relativistic geodesy.

preprint2013arXiv

New Limit on Lorentz Violation Using a Double-Pass Optical Ring Cavity

A search for Lorentz violation in electrodynamics was performed by measuring the resonant frequency difference between two counterpropagating directions of an optical ring cavity. Our cavity contains a dielectric element, which makes our cavity sensitive to the violation. The laser frequency is stabilized to the counterclockwise resonance of the cavity, and the transmitted light is reflected back into the cavity for resonant frequency comparison with the clockwise resonance. This double-pass configuration enables a null experiment and gives high common mode rejection of environmental disturbances. We found no evidence for odd-parity anisotropy at the level of $δc /c \lesssim 10^{-14}$. Within the framework of the Standard Model Extension, our result put more than 5 times better limits on three odd-parity parameters $\tildeκ^{JK}_{o+}$ and a 12 times better limit on the scalar parameter $\tildeκ_{\tr}$ compared with the previous best limits.