Researcher profile

Dino Di Carlo

Dino Di Carlo contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
6works
0followers
9topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2021arXiv

The Evolution of Flow and Mass Transport in 3D Confined Cavities

Flow in channels and ducts with adjoining cavities are common in natural and engineered systems. Here we report numerical and experimental results of 3D confined cavity flow, identifying critical conditions in the recirculating flow formation and mass transport over a range of channel flow properties ($0.1\leq Re \leq 300$) and cavity aspect ratio ($0.1 \leq H/X_{s} \leq1$). In contrast to 2D systems, a mass flux boundary is not formed in 3D confined cavity-channel flow. Streamlines directly enter a recirculating vortex in the cavity and exit to the main channel leading to an exponential increase in the cavity mass flux when the recirculating vortex fills the cavity volume. These findings extend our understanding of flow entry and exit in cavities and suggest conditions where convective mass transport into and out of cavities would be amplified and vortex particle capture reduced.

preprint2020arXiv

An Automated, Cost-Effective Optical System for Accelerated Anti-microbial Susceptibility Testing (AST) using Deep Learning

Antimicrobial susceptibility testing (AST) is a standard clinical procedure used to quantify antimicrobial resistance (AMR). Currently, the gold standard method requires incubation for 18-24 h and subsequent inspection for growth by a trained medical technologist. We demonstrate an automated, cost-effective optical system that delivers early AST results, minimizing incubation time and eliminating human errors, while remaining compatible with standard phenotypic assay workflow. The system is composed of cost-effective components and eliminates the need for optomechanical scanning. A neural network processes the captured optical intensity information from an array of fiber optic cables to determine whether bacterial growth has occurred in each well of a 96-well microplate. When the system was blindly tested on isolates from 33 patients with Staphylococcus aureus infections, 95.03% of all the wells containing growth were correctly identified using our neural network, with an average of 5.72 h of incubation time required to identify growth. 90% of all wells (growth and no-growth) were correctly classified after 7 h, and 95% after 10.5 h. Our deep learning-based optical system met the FDA-defined criteria for essential and categorical agreements for all 14 antibiotics tested after an average of 6.13 h and 6.98 h, respectively. Furthermore, our system met the FDA criteria for major and very major error rates for 11 of 12 possible drugs after an average of 4.02 h, and 9 of 13 possible drugs after an average of 9.39 h, respectively. This system could enable faster, inexpensive, automated AST, especially in resource limited settings, helping to mitigate the rise of global AMR.

preprint2019arXiv

Shape-design for stabilizing micro-particles in inertial microfluidic flows

Design of microparticles which stabilize at the centerline of a channel flow when part of a dilute suspension is examined numerically for moderate Reynolds numbers ($10 \le Re \le 80$). Stability metrics for particles with arbitrary shapes are formulated based on linear-stability theory. Particle shape is parametrized by a compact, Non-Uniform Rational B-Spline (NURBS)-based representation. Shape-design is posed as an optimization problem and solved using adaptive Bayesian optimization. We focus on designing particles for maximal stability at the channel-centerline robust to perturbations. Our results indicate that centerline-focusing particles are families of characteristic "fish"/"bottle"/"dumbbell"-like shapes, exhibiting fore-aft asymmetry. A parametric exploration is then performed to identify stable particle-designs at different k's (particle chord-to-channel width ratio) and Re's ($0.1 \le k \le 0.4, 10 \le Re \le 80$). Particles at high-k's and Re's are highly stabilized when compared to those at low-k's and Re's. A comparison of the modified dumbbell designs from the current framework also shows better performance to perturbations in Fluid-Structure Interaction (FSI) when compared to the rod-disk model reported previously (Uspal & Doyle 2014) for low-Re Hele-Shaw flow. We identify basins of attraction around the centerline, which span larger release-angle-ranges and lateral locations (tending to the channel width) for narrower channels, which effectively standardizes the notion of global focusing in such configurations using the current stability-paradigm. The present framework is illustrated for 2D cases and is potentially generalizable to stability in 3D flow-fields. The current formulation is also agnostic to Re and particle/channel geometry which indicates substantial potential for integration with imaging flow-cytometry tools and microfluidic biosensing-assays.

preprint2019arXiv

Spectro-temporal encoded Multiphoton Microscopy

Two-Photon Microscopy has become an invaluable tool for biological and medical research, providing high sensitivity, molecular specificity, inherent three-dimensional sub-cellular resolution and deep tissue penetration. In terms of imaging speeds, however, mechanical scanners still limit the acquisition rates to typically 10-100 frames per second. Here we present a high-speed non-linear microscope achieving kilohertz frame rates by employing pulse-modulated, rapidly wavelength-swept lasers and inertia-free beam steering through angular dispersion. In combination with a high bandwidth, single-photon sensitive detector, we achieve recording of fluorescent lifetimes at unprecedented speeds of 88 million pixels per second. We show diffraction-limited, multi-modal, Two-Photon fluorescence and fluorescence lifetime (FLIM), microscopy and imaging flow cytometry with a digitally reconfigurable laser, imaging system and data acquisition system. These unprecedented speeds should enable high-speed and high-throughput image-assisted cell sorting.

preprint2013arXiv

Lateral migration of living cells in inertial microfluidic systems explored by fully three-dimensional numerical simulation

The effects of cell size and deformability on the lateral migration and deformation of living cells flowing through a rectangular microchannel has been numerically investigated and compared with the inertial-microfluidics data on detection and separation of cells. The results of this work indicate that the cells move closer to the centerline if they are bigger and/or more deformable and that their equilibrium position is largely determined by the solvent (cytosol) viscosity, which is much less than the polymer (cytoskeleton) viscosity measured in most rheological systems. Simulations also suggest that decreasing channel dimensions leads to larger differences in equilibrium position for particles of different viscoelastic properties, giving design guidance for the next generation of microfluidic cell separation chips.

preprint2011arXiv

Inertially-induced secondary flow in microchannels

We report a novel technique to passively create strong secondary flows at moderate to high flow rates in microchannels, accurately control them and finally, due to their deterministic nature, program them into microfluidic platforms. Based on the flow conditions and due to the presence of the pillars in the channel, the flow streamlines will lose their fore-aft symmetry. As a result of this broken symmetry the fluid is pushed away from the pillar at the center of the channel (i.e. central z-plane). As the flow needs to maintain conservation of mass, the fluid will laterally travel in the opposite direction near the top and bottom walls. Therefore, a NET secondary flow will be created in the channel cross-section which is depicted in this video. The main platform is a simple straight channel with posts (i.e. cylindrical pillars - although other pillar cross-sections should also function) placed along the channel. Channel measures were 200 \mum\times50 \mum, with pillars of 100 \mum in diameter. Positioning the pillars in different locations within the cross-section of the channel will result in induction of different secondary flow patterns, which can be carefully engineered. The longitudinal spacing of the pillars is another design parameter (600 \mum spacing was used for this video). The device works over a wide range (moderate to high) flow rates. We used 150 \muL/min in this experiment. The device has 3 inlets where a dye stream is co-flowed between two water streams. In this video, one can see the effect of the net secondary flow created by inertia in the microchannel by visualizing the cross-section of the fluorescently labeled stream. Confocal images are sequentially taken at the inlet and after 49 consecutive pillars.