Source author record

Christian Hagemann

Christian Hagemann appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2014arXiv

A strontium lattice clock with $3 \times 10^{-17}$ inaccuracy and its frequency

We have measured the absolute frequency of the optical lattice clock based on $^{87}$Sr at PTB with an uncertainty of $3.9\times 10^{-16}$ using two caesium fountain clocks. This is close to the accuracy of today's best realizations of the SI second. The absolute frequency of the 5s$^2$ $^1$S$_0$-5s5p $^3$P$_0$ transition in $^{87}$Sr is 429,228,004,229,873.13(17) Hz. Our result is in excellent agreement with recent measurements performed in different laboratories worldwide. We improved the total systematic uncertainty of our Sr frequency standard by a factor of five and reach $3\times 10^{-17}$, opening new prospects for frequency ratio measurements between optical clocks for fundamental research, geodesy, or optical clock evaluation.

preprint2014arXiv

Ultra-stable laser with average fractional frequency drift rate below $5\times10^{-19}/\mathrm{s}$

Cryogenic single-crystal optical cavities have the potential to provide highest dimensional stability. We have investigated the long-term performance of an ultra-stable laser system which is stabilized to a single-crystal silicon cavity operated at 124 K. Utilizing a frequency comb, the laser is compared to a hydrogen maser that is referenced to a primary caesium fountain standard and to the $^{87}\mathrm{Sr}$ optical lattice clock at PTB. With fractional frequency instabilities of $σ_y(τ)\leq2\times10^{-16}$ for averaging times of $τ=60\mathrm{~s}$ to $1000\mathrm{~s}$ and $σ_y(1 \mathrm{d})\leq 2\times10^{-15}$ the stability of this laser, without any aid from an atomic reference, surpasses the best microwave standards for short averaging times and is competitive with the best hydrogen masers for longer times of one day. The comparison of modeled thermal response of the cavity with measured data indicates a fractional frequency drift below $5\times 10^{-19}/\mathrm{s}$, which we do not expect to be a fundamental limit.