Researcher profile

C. Lee

C. Lee contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
8works
0followers
11topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2022arXiv

Alpha backgrounds in the AMoRE-Pilot experiment

The Advanced Mo-based Rare process Experiment (AMoRE)-Pilot experiment is an initial phase of the AMoRE search for neutrinoless double beta decay of $^{100}$Mo, with the purpose of investigating the level and sources of backgrounds. Searches for neutrinoless double beta decay generally require ultimately low backgrounds. Surface $α$ decays on the crystals themselves or nearby materials can deposit a continuum of energies that can be as high as the $Q$-value of the decay itself and may fall in the region of interest (ROI). To understand these background events, we studied backgrounds from radioactive contaminations internal to and on the surface of the crystals or nearby materials with Geant4-based Monte Carlo simulations. In this study, we report on the measured $α$ energy spectra fitted with the corresponding simulated spectra for six crystal detectors, where sources of background contributions could be identified through high energy $α$ peaks and continuum parts in the energy spectrum for both internal and surface contaminations. We determine the low-energy contributions from internal and surface $α$ contaminations by extrapolating from the $α$ background fitting model.

preprint2022arXiv

Experimental measurement of kinetic parameters using quantum plasmonic sensing

Kinetic models are essential for describing how molecules interact in a variety of biochemical processes. The estimation of a model's kinetic parameters by experiment enables researchers to understand how pathogens, such as viruses, interact with other entities like antibodies and trial drugs. In this work, we report a simple proof-of-principle experiment that uses quantum sensing techniques to give a more precise estimation of kinetic parameters than is possible with a classical approach. The interaction we study is that of bovine serum albumin (BSA) binding to gold via an electrostatic mechanism. BSA is an important protein in biochemical research as it can be conjugated with other proteins and peptides to create sensors with a wide range of specificity. We use single photons generated via parametric down-conversion to probe the BSA-gold interaction in a plasmonic resonance sensor. We find that sub-shot-noise level fluctuations in the sensor signal allow us to achieve an improvement in the precision of up to 31.8% for the values of the kinetic parameters. This enhancement can in principle be further increased in the setup. Our work highlights the potential use of quantum states of light for sensing in biochemical research.

preprint2022arXiv

Measurement of binding kinetics using quantum plasmonic resonance sensing applied to HIV-1

The work done in this paper is an extension of the work done by Mpofu et al in [1]. The motivation for this paper is to show the potential of quantum bio-sensing techniques in applications to complex viruses like the human immunodeficiency virus (HIV) and to show it's potential in binding reactions where the signal is small and can potentially be buried in noise. In this paper we show theoretically that using quantum states of light such as the Fock state improves the precision in the estimation of kinetic parameters measured from the sensorgrams produced by the Kretschmann conguration. Though the Fock state is not the only quantum state in this study we look only at the Fock state because it has been shown to be the state which offers the best enhancement [1]. We show here that the Fock state allows us to measure the parameters more accurately in comparison to the classical (Coherent) state of light. We consider in this paper a binding reaction involving HIV type 1 (HIV-1). Specifically we look at the binding reaction between a variant of HIV-1 protease and nelnavir which is an inhibitor. Such a study is also offers value for drug discovery research as it points to the development of new technologies which can be applied to testing the efficacy of new drugs. Quantum technologies can prove to be useful in the fight against the HIV pandemic and assist in the continual research towards the development of treatments and a cure.

preprint2022arXiv

Measuring kinetic parameters using quantum plasmonic sensing

The measurement of parameters that describe kinetic processes is important in the study of molecular interactions. It enables a deeper understanding of the physical mechanisms underlying how different biological entities interact with each other, such as viruses with cells, vaccines with antibodies, or new drugs with specific diseases. In this work, we study theoretically the use of quantum sensing techniques for measuring the kinetic parameters of molecular interactions. The sensor we consider is a plasmonic resonance sensor -- a label-free photonic sensor that is one of the most widely used in research and industry. The first type of interaction we study is the antigen BSA interacting with antibody IgG1, which provides a large sensor response. The second type is the enzyme carbonic anhydrase interacting with the tumor growth inhibitor benzenesulfonamide, which produces a small sensor response. For both types of interaction we consider the use of two-mode Fock states, squeezed vacuum states and squeezed displaced states. We find that these quantum states offer an enhancement in the measurement precision of kinetic parameters when compared to that obtained with classical light. The results may help in the design of more precise quantum-based sensors for studying kinetics in the life sciences.

preprint2022arXiv

The LUX-ZEPLIN (LZ) radioactivity and cleanliness control programs

LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above $1.4 \times 10^{-48}$ cm$^{2}$ for a WIMP mass of 40 GeV/c$^{2}$ and a 1000 d exposure. LZ achieves this sensitivity through a combination of a large 5.6 t fiducial volume, active inner and outer veto systems, and radio-pure construction using materials with inherently low radioactivity content. The LZ collaboration performed an extensive radioassay campaign over a period of six years to inform material selection for construction and provide an input to the experimental background model against which any possible signal excess may be evaluated. The campaign and its results are described in this paper. We present assays of dust and radon daughters depositing on the surface of components as well as cleanliness controls necessary to maintain background expectations through detector construction and assembly. Finally, examples from the campaign to highlight fixed contaminant radioassays for the LZ photomultiplier tubes, quality control and quality assurance procedures through fabrication, radon emanation measurements of major sub-systems, and bespoke detector systems to assay scintillator are presented.

preprint2020arXiv

A free-floating or wide-orbit planet in the microlensing event OGLE-2019-BLG-0551

High-cadence observations of the Galactic bulge by the microlensing surveys led to the discovery of a handful of extremely short-timescale microlensing events that can be attributed to free-floating or wide-orbit planets. Here, we report the discovery of another strong free-floating planet candidate, which was found from the analysis of the gravitational microlensing event OGLE-2019-BLG-0551. The light curve of the event is characterized by a very short duration (<3 d) and a very small amplitude (< 0.1 mag). From modeling of the light curve, we find that the Einstein timescale, tE = 0.381 +/- 0.017 d, is much shorter, and the angular Einstein radius, thetaE = 4.35 +/- 0.34 uas, is much smaller than those of typical lensing events produced by stellar-mass lenses (tE ~ 20 d, thetaE ~ 0.3 mas), indicating that the lens is very likely to be a planetary-mass object. We conduct an extensive search for possible signatures of a companion star in the light curve of the event, finding no significant evidence for the putative host star. For the first time, we also demonstrate that the angular Einstein radius of the lens does not depend on blending in the low-magnification events with strong finite source effects.

preprint2019arXiv

Enhanced negative nonlocal conductance in an interacting quantum dot connected to two ferromagnetic leads and one superconducting lead

In this paper, we investigate the electronic transport properties of a quantum dot (QD) connected to two ferromagnetic leads and one superconductor lead in the Kondo regime by means of the finite-$U$ slave boson mean field approach and nonequilibrium Green function technique. In this three-terminal hybrid nano-device, we will focus our attention on the joint effects of the Konod correlation, superconducting proximity pairing, and spin polarization of leads. It is found that: the superconducting proximity effect will suppress the linear local conductance (LLC) stemming from the weakened Kondo peak, and when its coupling $Γ_s$ is bigger than the tunnel-coupling $Γ$ of two normal leads, the linear cross conductance (LCC) becomes negative in the Kondo region; for antiparallel configuration, increasing spin polarization further suppresses LLC but enhances LCC, i.e. causing larger negative values of LCC, since it is benefit for emergence of cross Andreev reflection; On the contrary, for parallel configuration, with increasing spin polarization, the LLC descends and greatly widens with the appearance of shoulders, and eventually splits into four peaks, and meanwhile the LCC reduces relatively rapidly to the normal conductance.

preprint2019arXiv

Extending light WIMP searches to single scintillation photons in LUX

We present a novel analysis technique for liquid xenon time projection chambers that allows for a lower threshold by relying on events with a prompt scintillation signal consisting of single detected photons. The energy threshold of the LUX dark matter experiment is primarily determined by the smallest scintillation response detectable, which previously required a 2-fold coincidence signal in its photomultiplier arrays, enforced in data analysis. The technique presented here exploits the double photoelectron emission effect observed in some photomultiplier models at vacuum ultraviolet wavelengths. We demonstrate this analysis using an electron recoil calibration dataset and place new constraints on the spin-independent scattering cross section of weakly interacting massive particles (WIMPs) down to 2.5 GeV/c$^2$ WIMP mass using the 2013 LUX dataset. This new technique is promising to enhance light WIMP and astrophysical neutrino searches in next-generation liquid xenon experiments.