Source author record

Brannon B. Klopfer

Brannon B. Klopfer appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
8topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2023arXiv

Nanosecond Photoemission near the Potential Barrier of a Schottky Emitter

Nanosecond electron pulses are appealing for ultrafast imaging and electron gating applications, where tunable currents and narrow energy spreads are desirable. Here, we demonstrate photoemission from a Schottky emitter triggered by nanosecond laser pulses and use a dispersive magnetic prism array to image the electron energy distributions. Using photon energies optimally tuned to the emission potential barrier, we generate pulses containing over 10$^5$ electrons with energy spreads below 1 eV with a prompt, single-photon emission process. These results are consistent with theoretical models of laser-triggered electron emission and energetic broadening during propagation and can be widely implemented.

preprint2019arXiv

Efficient wide-field FLIM

Nanosecond temporal resolution enables new methods for wide-field imaging like time-of-flight, gated detection, and fluorescence lifetime. The optical efficiency of existing approaches, however, presents challenges for low-light applications common to fluorescence microscopy and single-molecule imaging. We demonstrate the use of Pockels cells for wide-field image gating with nanosecond temporal resolution and high photon collection efficiency. Two temporal frames are obtained by combining a Pockels cell with a pair of polarizing beam-splitters. We show multi-label fluorescence lifetime imaging microscopy (FLIM), single-molecule lifetime spectroscopy, and fast single-frame FLIM at the camera frame rate with $10^3 - 10^5$ times higher throughput than single photon counting. Finally, we demonstrate a space-to-time image multiplexer using a re-imaging optical cavity with a tilted mirror to extend the Pockels cell technique to multiple temporal frames. These methods enable nanosecond imaging with standard optical systems and sensors, opening a new temporal dimension for low-light microscopy.

preprint2016arXiv

Multi-pass transmission electron microscopy

Feynman once asked physicists to build better electron microscopes to be able to watch biology at work. While electron microscopes can now provide atomic resolution, electron beam induced specimen damage precludes high resolution imaging of sensitive materials, such as single proteins or polymers. Here, we use simulations to show that an electron microscope based on a simplemulti-pass measurement protocol enables imaging of single proteins at reduced damage and at nanometer resolution, without averaging structures overmultiple images. Whilewe demonstrate the method for particular imaging targets, the approach is broadly applicable and is expected to improve resolution and sensitivity for a range of electron microscopy imaging modalities, including, for example, scanning and spectroscopic techniques. The approach implements a quantum mechanically optimal strategy which under idealized conditions can be considered interaction-free. In practice, an order-of-magnitude reduction in damage at equivalent resolution appears feasible.

preprint2015arXiv

Ultrafast time resolved photo-electric emission

The emission times of laser-triggered electrons from a sharp tungsten tip are directly characterized under ultrafast, near-infrared laser excitation at Keldysh parameters $6.6< γ< 19.1$. Emission delays up to 10 fs are observed, which are inferred from the energy gain of photoelectrons emitted into a synchronously driven microwave cavity. ~ fs timing resolution is achieved in a configuration capable of measuring timing shifts up to 55 ps. The technique can also be used to measure the microwave phase inside the cavity with a precision below 70 fs upon the energy resolved detection of a single electron.

preprint2012arXiv

Critical thickness for ferromagnetism in LaAlO3/SrTiO3 heterostructures

In heterostructures of LaAlO3 (LAO) and SrTiO3 (STO), two nonmagnetic insulators, various forms of magnetism have been observed [1-7], which may [8, 9] or may not [10] arise from interface charge carriers that migrate from the LAO to the interface in an electronic reconstruction [11]. We image the magnetic landscape [5] in a series of n-type samples of varying LAO thickness. We find ferromagnetic patches that appear only above a critical thickness, similar to that for conductivity [12]. Consequently we conclude that an interface reconstruction is necessary for the formation of magnetism. We observe no change in ferromagnetism with gate voltage, and detect ferromagnetism in a non-conducting p-type sample, indicating that the carriers at the interface do not need to be itinerant to generate magnetism. The fact that the ferromagnetism appears in isolated patches whose density varies greatly between samples strongly suggests that disorder or local strain induce magnetism in a population of the interface carriers.