Abstract
We report on a design of a compact laser system composed of an extended cavity diode laser with high passive stability and a pre-filter Fabri-Perot cavity. The laser is frequency stabilized relative to the cavity using a serrodyne technique with a correction bandwidth of MHz and a dynamic range of MHz. The free running laser system has a power spectral density (PSD) Hz/Hz centered mainly in the acoustic frequency range. A highly tunable, GHz copy of the spectrally pure output beam is provided, which can be used for further stabilization of the laser system to an ultra-stable reference. We demonstrate a simple one-channel lock to such a reference that brings down the PSD to the sub-Hz level. The tuning, frequency stabilization and sideband imprinting is achieved by a minimum number of key elements comprising a fibered EOM (electro-optic modulator), AOM (acousto-optic modulator) and a NLTL (non-linear transmission line). The system is easy to operate, scalable, and highly applicable to atomic/molecular experiments demanding high spectral purity, long-term stability, and robustness.