Researcher profile

Yuta Michimura

Yuta Michimura contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
16works
0followers
8topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

16 published item(s)

preprint2022arXiv

Angular trapping of a linear-cavity mirror with an optical torsional spring

Optomechanical systems have been attracting intensive attention in various physical experiments. With an optomechanical system, the displacement of or the force acting on a mechanical oscillator can be precisely measured by utilizing optical interferometry. As a mechanical oscillator, a suspended mirror is often used in over milligram scale optomechanical systems. However, the tiny suspended mirror in a linear cavity can be unstable in its yaw rotational degree of freedom due to optical radiation pressure. This instability curbs the optical power that the cavity can accumulate in it, and imposes a limitation on the sensitivity. Here, we show that the optical radiation pressure can be used to trap the rotational motion of the suspended mirror without additional active feedback control when the $g$ factors of the cavity are negative and one mirror is much heavier than the other one. Furthermore, we demonstrate experimentally the validity of the trapping. We measured the rotational stiffness of a suspended tiny mirror with various intracavity power. The result indicates that the radiation pressure of the laser beam inside the cavity actually works as a positive restoring torque. Moreover, we discuss the feasibility of observing quantum radiation pressure fluctuation with our experimental setup as an application of our trapping configuration.

preprint2022arXiv

Conceptual design and science cases of a juggled interferometer for gravitational wave detection

The Juggled interferometer (JIFO) is an earth-based gravitational wave detector using repeatedly free-falling test masses. With no worries of seismic noise and suspension thermal noise, the JIFO can have much better sensitivity at lower frequencies than the current earth-based gravitational wave detectors. The data readout method of a JIFO could be challenging if one adopts the fringe-locking method. We present a phase reconstruction method in this paper by building up a complex function which has a fringe-independent signal-to-noise ratio. Considering the displacement noise budget of the Einstein Telescope (ET), we show that the juggled test masses significantly improve the sensitivity at 0.1-2.5$\,$Hz even with discontinuous data. The science cases brought with the improved sensitivity would include detecting quasi-normal modes of black holes with $10^4-10^5\,M_{\odot}$, testing Brans-Dicke theory with black-hole and neutron-star inspirals, and detecting primordial-black-hole-related gravitational waves.

preprint2022arXiv

Displacement-noise-free neutron interferometer for gravitational wave detection using a single Mach-Zehnder configuration

The improvement of sensitivity to gravitational waves (GWs) at lower frequencies is still challenging on account of displacement noise. One of the solutions is the neutron displacement-noise-free interferometer (DFI). We focus on a simplification of the detector configuration by taking advantage of the ability to adjust the neutron speed depending on the configuration. The new configuration consists of two beamsplitters and two mirrors, which constitute a single Mach-Zehnder interferometer (MZI). It is simpler than the configuration with two MZIs in previous research. All displacement noise of mirrors and beamsplitters can be canceled in the frequency domain. This cancellation can be explained intuitively using a phasor diagram.

preprint2022arXiv

Neutron displacement noise-free interferometer for gravitational-wave detection

An interferometer design that cancels all displacement noises of its test masses and maintains a gravitational-wave (GW) signal by combining multiple detector signals is called a displacement noise-free interferometer (DFI). The idea has been considered previously for a laser interferometer. However, a limitation of a laser DFI is that its sensitive frequency band is too high for astrophysical GW sources, $\sim 10^5\,{\rm Hz}$ even for a kilometer-sized interferometer. To circumvent this limitation, in this paper, we propose a neutron DFI, in which neutrons are used instead of light. Since neutrons have velocities much lower than the speed of light, the sensitive frequency band of a neutron DFI can be lowered down to $\sim 10^{-1}\,{\rm Hz}$. Therefore, a neutron DFI can be utilized for detecting GWs that are inaccessible by an ordinary laser interferometer on the ground.

preprint2022arXiv

Stochastic effects on observation of ultralight bosonic dark matter

Ultralight bosonic particles are fascinating candidates of dark matter (DM). It behaves as classical waves in our Galaxy due to its large number density. There have been various methods proposed to search for the wave-like DM, such as methods utilizing interferometric gravitational-wave detectors. Understanding the characteristics of DM signals is crucial to extract the properties of DM from data. While the DM signal is nearly monochromatic with the angular frequency of its mass, the amplitude and phase are gradually changing due to the velocity dispersion of DMs in our Galaxy halo. The stochastic amplitude and phase should be properly taken into account to accurately constrain the coupling constant of DM from data. Previous works formulated a method to obtain the upper bound on the coupling constant incorporating the stochastic effects. One of these works compared the upper bound with and without the stochastic effect in a measurement time that is much shorter than the variation time scale of the amplitude and phase. In this paper, we extend their formulation to arbitrary measurement time and evaluate the stochastic effects. Moreover, we investigate the velocity-dependent signal for dark photon DM including an uncertainly of the velocity. We demonstrate that our method accurately estimates the upper bound on the coupling constant with numerical simulations. We also estimate the expected upper bound of the coupling constant of axion DM and dark photon DM from future experiments in a semi-analytic way. The stochasticity especially affects constraints on a small mass region. Our formulation offers a generic treatment of the ultralight bosonic DM signal with the stochastic effect.

preprint2022arXiv

Wavefront Sensing with a Coupled Cavity for Torsion-Bar Antenna

Torsion-Bar Antenna (TOBA) is a ground-based gravitational wave detector using torsion pendulums. TOBA can detect intermediate-mass black hole binary mergers, gravitational wave stochastic background, and Newtonian noise, and is useful for earthquake early warning. A prototype detector Phase-III TOBA with 35 cm-scale pendulums is under development to demonstrate noise reduction. The target strain sensitivity is set to $1\times10^{-15}\,{/\sqrt{\rm Hz}}$ between 0.1 Hz--10 Hz. A new scheme of wavefront sensing with a coupled cavity was proposed to measure the pendulum rotation as low as $5\times10^{-16}\,{{\rm rad}/\sqrt{\rm Hz}}$ for Phase-III TOBA. In our method, an auxiliary cavity is used to enhance the first-order Hermite--Gaussian mode in a main cavity. Experimental demonstration is ongoing to confirm the feasibility of angular signal amplification and establish a method for locking a coupled cavity. We evaluated the performance of the coupled cavity and concluded that angular signal amplification would be feasible with this sensor. The coupled cavity was successfully locked to the resonance by the Pound--Drever--Hall technique with two modulation frequencies.

preprint2021arXiv

Dark matter Axion search with riNg Cavity Experiment DANCE: Design and development of auxiliary cavity for simultaneous resonance of linear polarizations

Axion-like particles (ALPs) are undiscovered pseudo-scalar particles that are candidates for ultralight dark matter. ALPs interact with photons slightly and cause the rotational oscillation of linearly polarized light. Dark matter Axion search with riNg Cavity Experiment (DANCE) searches for ALP dark matter by amplifying the rotational oscillation with a bow-tie ring cavity. Simultaneous resonance of linear polarizations is necessary to amplify both the carrier field and the ALP signal, and to achieve the design sensitivity. The sensitivity of the current prototype experiment DANCE Act-1 is less than expectation by around three orders of magnitude due to the resonant frequency difference between s- and p-polarization in the bow-tie ring cavity. In order to tune the resonant frequency difference, the method of introducing an auxiliary cavity was proposed. We designed an auxiliary cavity that can cancel out the resonant frequency difference and realize simultaneous resonance, considering optical loss. We also confirmed that the sensitivity of DANCE Act-1 with the auxiliary cavity can reach the original sensitivity.

preprint2021arXiv

First observation and analysis of DANCE: Dark matter Axion search with riNg Cavity Experiment

Dark matter Axion search with riNg Cavity Experiment (DANCE) was proposed to search for axion dark matter [Phys. Rev. Lett. 121, 161301 (2018)]. We aim to detect the rotation and oscillation of optical linear polarization caused by axion-photon coupling with a bow-tie cavity. DANCE can improve the sensitivity to axion-photon coupling constant $g_{a γ}$ for axion mass $m_a < 10^{-10}~\rm{eV}$ by several orders of magnitude compared to the best upper limits at present. A prototype experiment DANCE Act-1 is ongoing to demonstrate the feasibility of the method and to investigate technical noises. The optics was assembled and the performance of the cavity was evaluated. The first 12-day observation was successfully performed in May 2021. We reached $3 \times 10^{-6}~\rm{rad/\sqrt{Hz}}$ at $10~\rm{Hz}$ in the one-sided amplitude spectral density of the rotation angle of linear polarization.

preprint2021arXiv

Improvement of the target sensitivity in DECIGO by optimizing its parameters for quantum noise including the effect of diffraction loss

DECIGO is the future Japanese gravitational wave detector in outer space. We previously set the default design parameters to provide a good target sensitivity to detect the primordial gravitational waves (GWs). However, the updated upper limit of the primordial GWs by the Planck observations motivated us for further optimization of the target sensitivity. Previously, we had not considered optical diffraction loss due to the very long cavity length. In this paper, we optimize various DECIGO parameters by maximizing the signal-to-noise ratio (SNR), for the primordial GWs to quantum noise including the effects of diffraction loss. We evaluated the power spectrum density for one cluster in DECIGO utilizing the quantum noise of one differential Fabry-Perot interferometer. Then we calculated the SNR by correlating two clusters in the same position. We performed the optimization for two cases: the constant mirror-thickness case and the constant mirror-mass case. As a result, we obtained the SNR dependence on the mirror radius, which also determines various DECIGO parameters. This result is the first step toward optimizing the DECIGO design by considering the practical constraints on the mirror dimension and implementing other noise sources.

preprint2021arXiv

Ultralight dark matter searches with KAGRA gravitational wave telescope

Among various dark matter candidates, bosonic ultralight fields with masses below 1~eV are well motivated. Recently, a number of novel approaches have been put forward to search for ultralight dark matter candidates using laser interferometers at various scales. Those include our proposals to search for axion-like particles (ALPs) and vector fields with laser interferometric gravitational wave detectors. ALPs can be searched for by measuring the oscillating polarization rotation of laser light. Massive vector fields weakly coupled to the standard model sector can also be searched for by measuring the oscillating forces acting on the suspended mirrors of the interferometers. In this paper, the current status of the activities to search for such ultralight dark matter candidates using a gravitational wave detector in Japan, KAGRA, is reviewed. The analysis of data from KAGRA&#39;s observing run in 2020 to search for vector dark matter, and the installation of polarization optics to the arm cavity transmission ports of the interferometer to search for ALPs in future observing runs are underway.

preprint2020arXiv

Atto-Nm Torque Sensing with a Macroscopic Optomechanical Torsion Pendulum

Precise measurements of the displacement of, and force acting on, a mechanical oscillator can be performed by coupling the oscillator to an optical cavity. Brownian thermal forces represent a fundamental limit to measurement sensitivity which impedes the ability to use precise force measurements as a tool of fundamental enquiry, particularly in the context of macroscopic quantum measurements and table-top gravitational experiments. A torsion pendulum with a low mechanical resonant frequency can be limited by very small thermal forces - from its suspensions - at frequencies above resonance. Here, we report torque sensing of a 10-mg torsion pendulum formed by a bar mirror, using two optical cavities on either edge. The rotational mode was measured by subtracting the two signals from the cavities, while intracavity radiation pressure forces were used to trap the torsional mode with a 1 kHz optical spring. The resulting torque sensitivity of 20 aNm/$\sqrt{\rm Hz}$ is a record for a milligram scale torsion pendulum. Such a massive optomechanical device featuring high sensitivity can shed light on macroscopic quantum mechanics and gravitational physics.

preprint2020arXiv

Current status of space gravitational wave antenna DECIGO and B-DECIGO

Deci-hertz Interferometer Gravitational Wave Observatory (DECIGO) is the future Japanese space mission with a frequency band of 0.1 Hz to 10 Hz. DECIGO aims at the detection of primordial gravitational waves, which could be produced during the inflationary period right after the birth of the universe. There are many other scientific objectives of DECIGO, including the direct measurement of the acceleration of the expansion of the universe, and reliable and accurate predictions of the timing and locations of neutron star/black hole binary coalescences. DECIGO consists of four clusters of observatories placed in the heliocentric orbit. Each cluster consists of three spacecraft, which form three Fabry-Perot Michelson interferometers with an arm length of 1,000 km. Three clusters of DECIGO will be placed far from each other, and the fourth cluster will be placed in the same position as one of the three clusters to obtain the correlation signals for the detection of the primordial gravitational waves. We plan to launch B-DECIGO, which is a scientific pathfinder of DECIGO, before DECIGO in the 2030s to demonstrate the technologies required for DECIGO, as well as to obtain fruitful scientific results to further expand the multi-messenger astronomy.

preprint2020arXiv

Prospects for improving the sensitivity of the cryogenic gravitational wave detector KAGRA

Upgrades to improve the sensitivity of gravitational wave detectors enable more frequent detections and more precise source parameter estimation. Unlike other advanced interferometric detectors such as Advanced LIGO and Advanced Virgo, KAGRA requires different approach for the upgrade since it is the only detector which employs cryogenic cooling of the test masses. In this paper, we describe possible KAGRA upgrades with technologies focusing on different detector bands, and compare the impacts on the detection of compact binary coalescences. We show that either fivefold improvement in the $100 M_{\odot}$--$100 M_{\odot}$ binary black hole range, a factor of 1.3 improvement in the binary neutron star range, or a factor of 1.7 improvement in the sky localization of binary neutron stars is well feasible with upgrades that do not require changes in the existing cryogenic or vacuum infrastructure. We also show that twofold broadband sensitivity improvement is possible by applying multiple upgrades to the detector.

preprint2020arXiv

Quantum sensing with milligram scale optomechanical systems

Probing the boundary between classical and quantum mechanics has been one of the central themes in modern physics. Recently, experiments to precisely measure the force acting on milligram scale oscillators with optical cavities are attracting interest as promising tools to test quantum mechanics, decoherence mechanisms, and gravitational physics. In this paper, we review the present status of experiments using milligram scale optomechanical systems. We compare the feasibility of reaching the quantum regime with a pendulum, torsion pendulum, and optically levitated mirror. Considerations for designing a high $Q$ pendulum, condition for torsion pendulums to have better force sensitivity than pendulums, and constraints in designing optical levitation of a mirror are presented.

preprint2019arXiv

DANCE: Dark matter Axion search with riNg Cavity Experiment

We have proposed a new approach to search for axion dark matter with an optical ring cavity [Phys. Rev. Lett. 121, 161301 (2018)]. The coupling of photons to axions or axion-like particles makes a modulated difference in the phase velocity between left- and right-handed photons. Our method is to measure this phase velocity difference with a ring cavity, by measuring the resonant frequency difference between two circular polarizations. Our estimation shows that the sensitivity to axion-photon coupling constant $g_{a γ}$ for axion mass $m \lesssim 10^{-10}$ eV can be improved by several orders of magnitude compared with the current best limits. In this paper, we present the principles of the Dark matter Axion search with riNg Cavity Experiment (DANCE) and the status of the prototype experiment, DANCE Act-1.

preprint2019arXiv

Influence of non-uniformity in sapphire substrates for a gravitational wave telescope

Construction of a large-scale cryogenic gravitational-wave telescope KAGRA has been completed and the four sapphire test masses have been installed in cryostat vacuum chambers. It recently turned out that a sapphire substrate used for one of the input test masses shows a characteristic strcuture in its transmission map due to non-uniformity of the crystal. We performed an interferometer simulation to see the influence of the non-uniformity using measured transmission/reflection maps.