Source author record

Yohan Payan

Yohan Payan appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

20works
9topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

20 published item(s)

preprint2022arXiv

Biomechanical Lower Limb Model to Predict Patellar Position Alteration after Medial Open Wedge High Tibial Osteotomy

Medial open-wedge high tibial osteotomy is a surgical treatment for patients with a varus deformity and early-stage medial knee osteoarthritis. Observations suggest that this surgery can negatively affect the patellofemoral joint and change the patellofemoral kinematics. However, what causes these effects and how the correction angle can change the surgery's impact on the patellofemoral joint has not been investigated before. The objective of this study was to develop a biomechanical model that can predict the surgery's impact on the patellar position and find the correlation between the opening angles and the patellar position after the surgery. A combined finite element and multibody model of the lower limb was developed. The model's capabilities for predicting the patellofemoral kinematics were evaluated by performing a passive deep flexion simulation of the native knee and comparing the outcomes with magnetic resonance images of the study subject at various flexion angles. The model at a fixed knee flexion angle was then used to simulate the high tibial osteotomy surgery virtually. The results showed a correlation between the wedge opening angles and the patellar position in various degrees of freedom. These results indicate that larger wedge openings result in increased values of patellar distalization, lateral patellar shift, patellar rotation, and patellar internal tilt. The developed model in this study can be used in future studies to monitor the stress distribution on the patellar cartilage and connecting tissues to investigate their relationship with observations of pain and cartilage injury due to post-operative altered patellar kinematics.

preprint2014arXiv

Smart Diabetic Socks: Embedded device for diabetic foot prevention

1) Objectives Most foot ulcers are the consequence of a trauma (repetitive high stress, ill-fitting footwear, or an object inside the shoe) associated to diabetes. They are often followed by amputation and shorten life expectancy. This paper describes the prototype of the Smart Diabetic Socks that has been developed in the context of the French ANR TecSan project. The objective is to prevent pressure foot ulcers for diabetic persons. 2) Material and methods A fully wireless, customizable and washable "smart sock" has been designed. It is made of a textile which fibers are knitted in a way they provide measurements of the pressure exerted under and all around the foot in real-life conditions. This device is coupled with a subject-specific Finite Element foot model that simulates the internal strains within the soft tissues of the foot. 3) Results A number of derived stress indicators can be computed based on that analysis, such as the accumulated stress dose, high internal strains or peak pressures near bony prominences during gait. In case of risks for pressure ulcer, an alert is sent to the person and/or to the clinician. A watch, a smart-phone or a distant laptop can be used for providing such alert.

preprint2013arXiv

A biomechanical modeling study of the effects of the orbicularis oris muscle and jaw posture on lip shape

Purpose: The authors' general aim is to use biomechanical models of speech articulators to explore how possible variations in anatomical structure contribute to differences in articulatory strategies and phone systems across human populations. Specifically, they investigated 2 issues: (a) the link between lip muscle anatomy and variability in lip gestures and (b) the constraints of coupled lip/jaw biomechanics on jaw posture in labial sounds. Method: The authors used a model coupling the jaw, tongue, and face. First, the influence of the orbicularis oris (OO) anatomical implementation was analyzed by assessing how changes in depth (from epidermis to the skull) and peripheralness (proximity to the lip horn center) affected lip shaping. Second, the capability of the lip/jaw system to generate protrusion and rounding, or labial closure, was evaluated for different jaw heights. Results: Results showed that a peripheral and moderately deep OO implementation is most appropriate for protrusion and rounding; a superficial implementation facilitates closure; protrusion and rounding require a high jaw position; and closure is achievable for various jaw heights. Conclusions: Models provide objective information regarding possible links between anatomical and speech production variability across humans. Comparisons with experimental data will illustrate how motor control and cultural factors cope with these constraints.

preprint2013arXiv

Effect of saccades in tongue electrotactile stimulation for vision substitution applications

The visual substitution paradigm aims to facilitate the life of blind people. Generally one uses electro-stimulating devices where electrodes are arranged into arrays to stimulate the skin or the tongue mucosa to send signals of visual type to the subjects. When an electro-stimulation signal is applied continuously (e.g. when static visual scenes are displayed for a long period of time), the receptors of the affected region can get saturated and the patient may lose the displayed information. We propose here some mechanisms that ameliorate the quality of perception of the electro-stimulation information. The electrical signal is encoded as 2D scenes projected onto the tongue via a Tongue Display Unit, i.e. an electro-tactile stimulator formed by a 12x12 matrix of electrodes. We propose to apply stochastic saccades on this signal. Our assumption is that this eye-inspired mechanism should make the visual substitution more efficient (by improving the perception) because of the reduction of the tactile receptors saturation. The influence of saccades was evaluated by a series of experiments. Results revealed a benefit on the persistence of perception due to saccades. This work helps to prevent the saturation of receptors on the tongue. Therefore increasing the quality of vision by the way of the electro-stimulation. It allows new enhancement features to retinal prosthesis devices which suffer from the same phenomenon.

preprint2013arXiv

Electrotactile vision substitution for 3D trajectory following

Navigation for blind persons represents a challenge for researchers in vision substitution. In this field, one of the used techniques to navigate is guidance. In this study, we develop a new approach for 3D trajectory following in which the requested task is to track a light path using computer input devices (keyboard and mouse) or a rigid body handled in front of a stereoscopic camera. The light path is visualized either on direct vision or by way of a electro-stimulation device, the Tongue Display Unit, a 12x12 matrix of electrodes. We improve our method by a series of experiments in which the effect of the modality of perception and that of the input device. Preliminary results indicated a close correlation between the stimulated and recorded trajectories.

preprint2010arXiv

A fast and robust patient specific Finite Element mesh registration technique: application to 60 clinical cases

Finite Element mesh generation remains an important issue for patient specific biomechanical modeling. While some techniques make automatic mesh generation possible, in most cases, manual mesh generation is preferred for better control over the sub-domain representation, element type, layout and refinement that it provides. Yet, this option is time consuming and not suited for intraoperative situations where model generation and computation time is critical. To overcome this problem we propose a fast and automatic mesh generation technique based on the elastic registration of a generic mesh to the specific target organ in conjunction with element regularity and quality correction. This Mesh-Match-and-Repair (MMRep) approach combines control over the mesh structure along with fast and robust meshing capabilities, even in situations where only partial organ geometry is available. The technique was successfully tested on a database of 5 pre-operatively acquired complete femora CT scans, 5 femoral heads partially digitized at intraoperative stage, and 50 CT volumes of patients' heads. The MMRep algorithm succeeded in all 60 cases, yielding for each patient a hex-dominant, Atlas based, Finite Element mesh with submillimetric surface representation accuracy, directly exploitable within a commercial FE software.

preprint2007arXiv

A 3D biomechanical vocal tract model to study speech production control: How to take into account the gravity?

This paper presents a modeling study of the way speech motor control can deal with gravity to achieve steady-state tongue positions. It is based on simulations carried out with the 3D biomechanical tongue model developed at ICP, which is now controlled with the Lambda model (Equilibrium-Point Hypothesis). The influence of short-delay orosensory feedback on posture stability is assessed by testing different muscle force/muscle length relationships (Invariant Characteristics). Muscle activation patterns necessary to maintain the tongue in a schwa position are proposed, and the relations of head position, tongue shape and muscle activations are analyzed.

preprint2007arXiv

Guiding the surgical gesture using an electro-tactile stimulus array on the tongue: A feasibility study

Under conventional "open-" surgery, the physician has to take care of the patient, interact with other clinicians and check several monitoring devices. Nowadays, the Computer Assisted Surgery proposes to integrate 3D cameras in the operating theatre in order to assist the surgeon in performing minimal-invasive surgical punctures. The cameras localize the needle and the computer guides the surgeon towards an intracorporeal clinically-defined target. A visualization system (screen) is employed to provide the surgeon with indirect visual spatial information about the intracorporeal positions of the needle. The present work proposes to use another sensory modality to guide the surgeon thus keeping the visual modality fully dedicated to the surgical gesture. For this, the sensory substitution paradigm using the Bach-y-Rita's "Tongue Display Unit" (TDU) is exploited to provide to the surgeon information of the position tool. The TDU device is composed of a 6x6 matrix of electrodes transmitting electrotactile information on the tongue surface. The underlying idea consists in transmitting information about the deviation of the needle movement with regard to a pre-planned "optimal" trajectory. We present an experiment assessing the guidance effectiveness of an intracorporeal puncture under TDU guidance with respect to the performance evidenced under a usual visual guidance system.

preprint2006arXiv

3D Meshes Registration : Application to statistical skull model

In the context of computer assist surgical techniques, a new elastic registration method of 3D meshes is presented. In our applications, one mesh is a high density mesh (30000 vertexes), the second is a low density one (1000 vertexes). Registration is based upon the minimisation of a symmetric distance between both meshes, defined on the vertexes, in a multi resolution approach. Results on synthetic images are first presented. Then, thanks to this registration method, a statistical model of the skull is build from Computer Tomography exams collected for twelve patients.

preprint2006arXiv

3D statistical facial reconstruction

The aim of craniofacial reconstruction is to produce a likeness of a face from the skull. Few works in computerized assisted facial reconstruction have been done in the past, due to poor machine performances and data availability, and major works are manually reconstructions. In this paper, we present an approach to build 3D statistical models of the skull and the face with soft tissues from the skull of one individual. Results on real data are presented and seem promising.

preprint2006arXiv

A non-invasive device to measure mechanical interaction between tongue, palate and teeth during speech production

This paper describes an original experimental procedure to measure the mechanical interaction between the tongue and teeth and palate during speech production. It consists in using edentulous people as subjects and to insert pressure sensors in the structure of their complete dental prosthesis. Hence, there is no perturbation of the vocal tract cavity due to the sensors themselves. Several duplicates are used with transducers situated at different locations of the complete denture according to palatography's results, in order to carefully analyze the production of specific sounds such as stop consonants.. It is also possible to measure the contact pressure at different locations on the palate for the same sound.

preprint2006arXiv

A simulator for maxillo-facial surgery integrating cephalometry and orthodontia

Objectives : This paper presents a new simulator for maxillo-facial surgery, that gathers the dental and the maxillo-facial analyses together into a single computer-assisted procedure. The idea is first to propose a repositioning of the maxilla, via the introduction of a 3D cephalometry, applied to a 3D virtual model of the patient's skull. Then, orthodontic data are integrated into this model, thanks to optical measurements of teeth plaster casts. Materials and Methods : The feasibility of the maxillo-facial demonstrator was first evaluated on a dry skull. To simulate malformations (and thus to simulate a "real" patient), the skull was modified and manually cut by the surgeon, in order to generate a given maxillo-facial malformation (with asymmetries in the sagittal, frontal and axial planes). Results : The validation of our simulator consisted in evaluating its ability to propose a bone repositioning diagnosis that will put the skull as it was in its original configuration. A first qualitative validation is provided in this paper, with a 1.5-mm error in the repositioning diagnosis. Conclusions : These results mainly validate the concept of a maxillo-facial numerical simulator that integrates 3D cephalometry and guarantees a correct dental occlusion.

preprint2006arXiv

Control of Surgical Gesture under Lingual Electro-Tactile Stimulation

Performing minimal-invasive surgical punctures require guiding a needle toward an intracorporeal clinically-defined target. As this technique does not involve cutting the body open, a visualization system is employed to provide the surgeon with indirect visual spatial information about the intracorporeal positions of the tool. One may consider that such systems reduce the ergonomics of the situation as they generate a decorrelation between the actual movement of the needle and the displayed information about this movement. The present study aims at assessing the guidance of an intracorporeal puncture under a lingual electrotactile sensory substitution device - the Tongue Display Unit (TDU) - with respect to the performance evidenced under a computer-rendered visualization system. The TDU device provides information about the deviation of the needle movement with regard to a pre-planned "optimal" trajectory. Experimental results show that - (1) the stimulations furnished by the TDU are efficient enough to guide accurately one's puncture, - and (2) that previous training using the visualization system does not improve performances obtained under subsequent TDU guidance. Finally, results are discussed in terms of efficiency and usability of the TDU in the context of guiding minimally-invasive surgical gesture.

preprint2006arXiv

Evaluation of a lingual interface as a passive surgical guiding system

Under conventional "open-" surgery, the physician has to take care of the patient, interact with other clinicians and check several monitoring devices. Nowadays, the Computer Assisted Surgery proposes to integrate 3D cameras in the operating theatre in order to assist the surgeon in performing minimal-invasive surgical punctures. The cameras localize the needle and the computer guides the surgeon towards an intracorporeal clinically-defined target. A visualization system (screen) is employed to provide the surgeon with indirect visual spatial information about the intracorporeal positions of the needle. The present work proposes to use another sensory modality to guide the surgeon thus keeping the visual modality fully dedicated to the surgical gesture. For this, the sensory substitution paradigm using the Bach-y-Rita's "Tongue Display Unit" (TDU) is exploited to provide to the surgeon information of the position tool. The TDU device is composed of a 6x6 matrix of electrodes transmitting electrotactile information on the tongue surface. The underlying idea consists in transmitting information about the deviation of the needle movement with regard to a pre-planned "optimal" trajectory.

preprint2006arXiv

Reproduction of hypopnea phenomenon using a physical and numerical model

Obstructive sleep apnea syndrome is now considered as a major health care topic. An in-vitro setup which reproduces and simplifies upper airway geometry has been the basis to study the fluid/walls interaction that leads to an apnea. It consists of a rigid pipe (the pharynx) in contact with a deformable latex cylinder filled with water (the tongue). Air flows out of the rigid pipe and induces pressure forces on the cylinder. We present a numerical model of this setup: a finite element model of the latex cylinder is in interaction with a fluid model. Simulation of an hypopnea (partial collapsus of the airway) has been possible and in agreement with observations from the in-vitro setup. The same phenomenon has been simulated on a soft palate model obtained from a patient sagittal radiography. These first results encourage us to improve the model so as it could reproduce the complete apnea phenomenon, and be used for a planification purpose in sleep apnea surgery.

preprint2006arXiv

Statistical skull models from 3D X-ray images

We present 2 statistical models of the skull and mandible built upon an elastic registration method of 3D meshes. The aim of this work is to relate degrees of freedom of skull anatomy, as static relations are of main interest for anthropology and legal medicine. Statistical models can effectively provide reconstructions together with statistical precision. In our applications, patient-specific meshes of the skull and the mandible are high-density meshes, extracted from 3D CT scans. All our patient-specific meshes are registrated in a subject-shared reference system using our 3D-to-3D elastic matching algorithm. Registration is based upon the minimization of a distance between the high density mesh and a shared low density mesh, defined on the vertexes, in a multi resolution approach. A Principal Component analysis is performed on the normalised registrated data to build a statistical linear model of the skull and mandible shape variation. The accuracy of the reconstruction is under the millimetre in the shape space (after rigid registration). Reconstruction errors for Scan data of tests individuals are below registration noise. To take in count the articulated aspect of the skull in our model, Kernel Principal Component Analysis is applied, extracting a non-linear parameter associated with mandible position, therefore building a statistical articulated 3D model of the skull.

preprint2006arXiv

The mesh-matching algorithm: an automatic 3D mesh generator for Finite element structures

Several authors have employed Finite Element Analysis (FEA) for stress and strain analysis in orthopaedic biomechanics. Unfortunately, the use of three-dimensional models is time consuming and consequently the number of analysis to be performed is limited. The authors have investigated a new method allowing automatically 3D mesh generation for structures as complex as bone for example. This method called Mesh-Matching (M-M) algorithm generated automatically customized 3D meshes of bones from an already existing model. The M-M algorithm has been used to generate FE models of ten proximal human femora from an initial one which had been experimentally validated. The new meshes seemed to demonstrate satisfying results.

preprint2006arXiv

Utilisation de la substitution sensorielle par électro-stimulation linguale pour la prévention des escarres chez les paraplégiques. Etude préliminaire

Pressure ulcers are recognized as a major health issue in individuals with spinal cord injuries and new approaches to prevent this pathology are necessary. An innovative health strategy is being developed through the use of computer and sensory substitution via the tongue in order to compensate for the sensory loss in the buttock area for individuals with paraplegia. This sensory compensation will enable individuals with spinal cord injuries to be aware of a localized excess of pressure at the skin/seat interface and, consequently, will enable them to prevent the formation of pressure ulcers by relieving the cutaneous area of suffering. This work reports an initial evaluation of this approach and the feasibility of creating an adapted behavior, with a change in pressure as a response to electro-stimulated information on the tongue. Obtained during a clinical study in 10 healthy seated subjects, the first results are encouraging, with 92% success in 100 performed tests. These results, which have to be completed and validated in the paraplegic population, may lead to a new approach to education in health to prevent the formation of pressure ulcers within this population. Keywords: Spinal Cord Injuries, Pressure Ulcer, Sensory Substitution, Health Education, Biomedical Informatics.