Source author record

Y. Mei

Y. Mei appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

36works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

36 published item(s)

preprint2022arXiv

An Energy-dependent Electro-thermal Response Model of CUORE Cryogenic Calorimeter

The Cryogenic Underground Observatory for Rare Events (CUORE) is the most sensitive experiment searching for neutrinoless double-beta decay ($0νββ$) in $^{130}\text{Te}$. CUORE uses a cryogenic array of 988 TeO$_2$ calorimeters operated at $\sim$10 mK with a total mass of 741 kg. To further increase the sensitivity, the detector response must be well understood. Here, we present a non-linear thermal model for the CUORE experiment on a detector-by-detector basis. We have examined both equilibrium and dynamic electro-thermal models of detectors by numerically fitting non-linear differential equations to the detector data of a subset of CUORE channels which are well characterized and representative of all channels. We demonstrate that the hot-electron effect and electric-field dependence of resistance in NTD-Ge thermistors alone are inadequate to describe our detectors' energy dependent pulse shapes. We introduce an empirical second-order correction factor in the exponential temperature dependence of the thermistor, which produces excellent agreement with energy-dependent pulse shape data up to 6 MeV. We also present a noise analysis using the fitted thermal parameters and show that the intrinsic thermal noise is negligible compared to the observed noise for our detectors.

preprint2022arXiv

Enhanced low-energy supernova burst detection in large liquid argon time projection chambers enabled by Q-Pix

The detection of neutrinos from core-collapse supernovae may reveal important process features as well as neutrino properties. The detection of supernova neutrinos is one of the main science drivers for future kiloton-scale neutrino detectors based on liquid argon. Here we show that for such detectors the intrinsically 3D readout in Q-Pix offers numerous advantages relative to a wire-based readout, such as higher reconstruction efficiency, lower energy threshold, considerably lower data rates, and potential pointing information.

preprint2022arXiv

Optimization of the first CUPID detector module

CUPID will be a next generation experiment searching for the neutrinoless double $β$ decay, whose discovery would establish the Majorana nature of the neutrino. Based on the experience achieved with the CUORE experiment, presently taking data at LNGS, CUPID aims to reach a background free environment by means of scintillating Li$_{2}$$^{100}$MoO$_4$ crystals coupled to light detectors. Indeed, the simultaneous heat and light detection allows us to reject the dominant background of $α$ particles, as proven by the CUPID-0 and CUPID-Mo demonstrators. In this work we present the results of the first test of the CUPID baseline module. In particular, we propose a new optimized detector structure and light sensors design to enhance the engineering and the light collection, respectively. We characterized the heat detectors, achieving an energy resolution of (5.9 $\pm$ 0.2) keV FWHM at the $Q$-value of $^{100}$Mo (about 3034 keV). We studied the light collection of the baseline CUPID design with respect to an alternative configuration which features gravity-assisted light detectors' mounting. In both cases we obtained an improvement in the light collection with respect to past measures and we validated the particle identification capability of the detector, which ensures an $α$ particle rejection higher than 99.9%, fully satisfying the requirements for CUPID.

preprint2022arXiv

Recoil imaging for directional detection of dark matter, neutrinos, and physics beyond the Standard Model

Recoil imaging entails the detection of spatially resolved ionization tracks generated by particle interactions. This is a highly sought-after capability in many classes of detector, with broad applications across particle and astroparticle physics. However, at low energies, where ionization signatures are small in size, recoil imaging only seems to be a practical goal for micro-pattern gas detectors. This white paper outlines the physics case for recoil imaging, and puts forward a decadal plan to advance towards the directional detection of low-energy recoils with sensitivity and resolution close to fundamental performance limits. The science case covered includes: the discovery of dark matter into the neutrino fog, directional detection of sub-MeV solar neutrinos, the precision study of coherent-elastic neutrino-nucleus scattering, the detection of solar axions, the measurement of the Migdal effect, X-ray polarimetry, and several other applied physics goals. We also outline the R&D programs necessary to test concepts that are crucial to advance detector performance towards their fundamental limit: single primary electron sensitivity with full 3D spatial resolution at the $\sim$100 micron-scale. These advancements include: the use of negative ion drift, electron counting with high-definition electronic readout, time projection chambers with optical readout, and the possibility for nuclear recoil tracking in high-density gases such as argon. We also discuss the readout and electronics systems needed to scale-up such detectors to the ton-scale and beyond.

preprint2022arXiv

Search for Majorana neutrinos exploiting millikelvin cryogenics with CUORE

The possibility that neutrinos may be their own antiparticles, unique among the known fundamental particles, arises from the symmetric theory of fermions proposed by Ettore Majorana in 1937. Given the profound consequences of such Majorana neutrinos, among which is a potential explanation for the matter-antimatter asymmetry of the universe via leptogenesis, the Majorana nature of neutrinos commands intense experimental scrutiny globally; one of the primary experimental probes is neutrinoless double beta ($0 νββ$) decay. Here we show results from the search for $0 νββ$ decay of $^{130}$Te, using the latest advanced cryogenic calorimeters with the CUORE experiment. CUORE, operating just 10 millikelvin above absolute zero, has pushed the state of the art on three frontiers: the sheer mass held at such ultra-low temperatures, operational longevity, and the low levels of ionising radiation emanating from the cryogenic infrastructure. We find no evidence for $0 νββ$ decay and set a lower bound of $T_{1/2}^{0 ν} > 2.2 \times 10^{25}$ years at a 90% credibility interval. We discuss potential applications of the advances made with CUORE to other fields such as direct dark matter, neutrino and nuclear physics searches and large-scale quantum computing, which can benefit from sustained operation of large payloads in a low-radioactivity, ultra-low temperature cryogenic environment.

preprint2022arXiv

Search for Neutrinoless $β^+EC$ Decay of $^{120}$Te with CUORE

CUORE is a large scale cryogenic experiment searching for neutrinoless double beta decay ($0νββ$) in $^{130}$Te. The CUORE detector is made of natural tellurium, providing the possibility of rare event searches on isotopes other than $^{130}$Te. In this work we describe a search for neutrinoless positron emitting electron capture ($0νβ^+EC$) decay in $^{120}$Te with a total TeO$_2$ exposure of 355.7 kg $\cdot$ yr, corresponding to 0.2405 kg $\cdot$ yr of $^{120}$Te. Albeit $0 νββ$ with two final state electrons represents the most promising channel, the emission of a positron and two 511-keV $γ$s make $0νβ^+EC$ decay signature extremely clear. To fully exploit the potential offered by the detector modularity we include events with different topology and perform a simultaneous fit of five selected signal signatures. Using blinded data we extract a median exclusion sensitivity of $3.4 \cdot 10^{22}$ yr at 90% Credibility Interval (C.I.). After unblinding we find no evidence of $0νβ^+EC$ signal and set a 90% C.I. Bayesian lower limit of $2.9 \cdot 10^{22}$ yr on $^{120}$Te half-life. This result improves by an order of magnitude the existing limit from the combined analysis of CUORE-0 and Cuoricino.

preprint2022arXiv

Snowmass 2021 White Paper: The Selena Neutrino Experiment

Imaging devices made from an ionization target layer of amorphous selenium (aSe) coupled to a silicon complementary metal-oxide-semiconductor (CMOS) active pixel array for charge readout are a promising technology for neutrino physics. The high spatial resolution in a solid-state target provides unparalleled rejection of backgrounds from natural radioactivity in the search for neutrinoless $ββ$ decay and for electron neutrino ($ν_e$) spectroscopy with $^{82}$Se. In this white paper, we summarize the broad scientific program of a large imaging detector with a 10-ton target of $^{82}$Se. We review the detector technology, and outline the ongoing research program to realize this experiment.

preprint2022arXiv

Toward CUPID-1T

Current experiments to search for broken lepton-number symmetry through the observation of neutrinoless double-beta decay ($0\mathrm{νββ}$) provide the most stringent limits on the Majorana nature of neutrinos and the effective Majorana neutrino mass ($m_{ββ}$). The next-generation experiments will focus on the sensitivity to the $0\mathrm{νββ}$ half-life of $\mathcal{O}(10^{27}$--$10^{28}$~years$)$ and $m_{ββ}\lesssim15$~meV, which would provide complete coverage of the so-called Inverted Ordering region of the neutrino mass parameter space. By taking advantage of recent technological breakthroughs, new, future calorimetric experiments at the 1-ton scale can increase the sensitivity by at least another order of magnitude, exploring the large fraction of the parameter space that corresponds to the Normal neutrino mass ordering. In case of a discovery, such experiments could provide important insights toward a new understanding of the mechanism of $0\mathrm{νββ}$. We present here a series of projects underway that will provide advancements in background reduction, cryogenic readout, and physics searches beyond $0\mathrm{νββ}$, all moving toward the next-to-next generation CUPID-1T detector.

preprint2021arXiv

New results from the CUORE experiment

The Cryogenic Underground Observatory for Rare Events (CUORE) is the first cryogenic experiment searching for neutrinoless double-beta ($0νββ$) decay that has been able to reach the one-ton scale. The detector, located at the Laboratori Nazionali del Gran Sasso in Italy, consists of an array of 988 TeO$_2$ crystals arranged in a compact cylindrical structure of 19 towers. Following the completion of the detector construction in August 2016, CUORE began its first physics data run in 2017 at a base temperature of about 10 mK. Following multiple optimization campaigns in 2018, CUORE is currently in stable operating mode. In 2019, CUORE released its 2\textsuperscript{nd} result of the search for $0νββ$ with a TeO$_2$ exposure of 372.5 kg$\cdot$yr and a median exclusion sensitivity to a $^{130}$Te $0νββ$ decay half-life of $1.7\cdot 10^{25}$ yr. We find no evidence for $0νββ$ decay and set a 90\% C.I. (credibility interval) Bayesian lower limit of $3.2\cdot 10^{25}$ yr on the $^{130}$Te $0νββ$ decay half-life. In this work, we present the current status of CUORE's search for $0νββ$, as well as review the detector performance. Finally, we give an update of the CUORE background model and the measurement of the $^{130}$Te two neutrino double-beta ($2νββ$) decay half-life.

preprint2020arXiv

Neutrinoless Double Beta Decay with $^{82}$SeF$_6$ and Direct Ion Imaging

We present a new neutrinoless double beta decay concept: the high pressure selenium hexafluoride gas time projection chamber. Combining techniques pioneered in high pressure xenon gas such as topological discrimination, with the high Q-value afforded by double beta decay isotope $^{82}$Se, a promising new detection technique is outlined. Lack of free electrons in SeF$_6$ mandates the use of an ion TPC. The microphysics of ion production and drift, which have many nuances, are explored. Background estimates are produced suggesting such a detector may achieve background indices of better than 1 count per ton per year in the region of interest at the 100~kg scale, and still better at the ton-scale.

preprint2020arXiv

The spatial distribution of quasi-biennial oscillations in the high-latitude solar activity

Quasi-biennial oscillations (QBOs) are considered as a fundamental mode of solar magnetic activity at low latitudes ($\leq50^\circ$). However, the evolutionary aspect and the hemispheric distribution of solar QBOs at high latitudes ($\geq60^\circ$) are rarely studied. Here, a relatively novel time-frequency analysis technique, named the synchrosqueezed wavelet transform, is applied to extract the main components of the polar faculae in the northern and southern hemispheres for the time interval from August 1951 to December 1998. It is found as the following: (1) Apart from the 22-year Hale cycle, the 17-year extended activity cycle, and the 11-year Schwabe cycle, the QBOs have been estimated as a prominent timescale of solar magnetic activity at high latitudes; (2) the QBOs of the polar faculae are coherent in the two hemispheres, but the temporal (phase) and the spatial (amplitude) variations of solar QBOs occur unevenly on both hemispheres; and (3) for the 11-year period mode, the northern hemisphere begins three months earlier than that in the southern one. Moreover, the spatial and temporal distributions of the hemispheric QBOs differ from those of the 11-year Schwabe cycle mode in the two hemispheres. Our findings could be helpful to improve our knowledge on the physical origin of the spatial distribution of solar QBOs at high latitudes, and could also provide more constraints on solar dynamo models introduced to characterize the different components of the solar magnetic activity cycle.

preprint2019arXiv

Improved Limit on Neutrinoless Double-Beta Decay in $^{130}$Te with CUORE

We report new results from the search for neutrinoless double-beta decay in $^{130}$Te with the CUORE detector. This search benefits from a four-fold increase in exposure, lower trigger thresholds and analysis improvements relative to our previous results. We observe a background of $(1.38\pm0.07)\cdot10^{-2}$ counts$/($keV$\cdot$kg$\cdot$yr$)$ in the $0νββ$ decay region of interest and, with a total exposure of 372.5 kg$\cdot$yr, we attain a median exclusion sensitivity of $1.7\cdot10^{25}$ yr. We find no evidence for $0νββ$ decay and set a $90\%$ CI Bayesian lower limit of $3.2\cdot10^{25}$ yr on the $^{130}$Te half-life for this process. In the hypothesis that $0νββ$ decay is mediated by light Majorana neutrinos, this results in an upper limit on the effective Majorana mass of 75-350 meV, depending on the nuclear matrix elements used.

preprint2019arXiv

Systematic Regularity of Solar Coronal Rotation During the Time Interval 1939-2019

Temporal variation of the solar coronal rotation appears to be very complex and its relevances to the eleven-year solar activity cycle are still unclear. Using the modified coronal index for the time interval from 1939 January 1 to 2019 May 31, the systematic regularities of the solar coronal rotation are investigated. Our main findings are as follows: (1) from a global point of view, the synodic coronal rotation period with a value of 27.5 days is the only significant period at the periodic scales shorter than 64 days; (2) the coronal rotation period exhibit an obviously decreasing trend during the considered time interval, implying the solar corona accelerates its global rotation rate in the long run; (3) there exist significant periods of 3.25, 6.13, 9.53, and 11.13 years in the period length of the coronal rotation, providing an evidence that the coronal rotation should be connected with the quasi-biennial oscillation, the eleven-year solar cycle, and the 22-year Hale cycle (or the magnetic activity reversal); and (4) the phase relationship between the coronal rotation period and the solar magnetic activity is not only time-dependent but also frequency-dependent. For a small range around the 11- year cycle band, there is a systematic trend in the phase, and the small mismatch in this band brings out the phase to drift. The possible mechanism for the above analysis results is discussed.

preprint2018arXiv

Double-beta decay of ${}^{130}$Te to the first $0^+$ excited state of ${}^{130}$Xe with CUORE-0

We report on a search for double beta decay of $^{130}$Te to the first $0^{+}$ excited state of $^{130}$Xe using a 9.8 kg$\cdot$yr exposure of $^{130}$Te collected with the CUORE-0 experiment. In this work we exploit different topologies of coincident events to search for both the neutrinoless and two-neutrino double-decay modes. We find no evidence for either mode and place lower bounds on the half-lives: $τ^{0ν}_{0^+}>7.9\cdot 10^{23}$ yr and $τ^{2ν}_{0^+}>2.4\cdot 10^{23}$ yr. Combining our results with those obtained by the CUORICINO experiment, we achieve the most stringent constraints available for these processes: $τ^{0ν}_{0^+}>1.4\cdot 10^{24}$ yr and $τ^{2ν}_{0^+}>2.5\cdot 10^{23}$ yr.

preprint2016arXiv

Analysis Techniques for the Evaluation of the Neutrinoless Double-Beta Decay Lifetime in $^{130}$Te with CUORE-0

We describe in detail the methods used to obtain the lower bound on the lifetime of neutrinoless double-beta ($0νββ$) decay in $^{130}$Te and the associated limit on the effective Majorana mass of the neutrino using the CUORE-0 detector. CUORE-0 is a bolometric detector array located at the Laboratori Nazionali del Gran Sasso that was designed to validate the background reduction techniques developed for CUORE, a next-generation experiment scheduled to come online in 2016. CUORE-0 is also a competitive $0νββ$ decay search in its own right and functions as a platform to further develop the analysis tools and procedures to be used in CUORE. These include data collection, event selection and processing, as well as an evaluation of signal efficiency. In particular, we describe the amplitude evaluation, thermal gain stabilization, energy calibration methods, and the analysis event selection used to create our final $0νββ$ decay search spectrum. We define our high level analysis procedures, with emphasis on the new insights gained and challenges encountered. We outline in detail our fitting methods near the hypothesized $0νββ$ decay peak and catalog the main sources of systematic uncertainty. Finally, we derive the $0νββ$ decay half-life limits previously reported for CUORE-0, $T^{0ν}_{1/2}>2.7\times10^{24}$ yr, and in combination with the Cuoricino limit, $T^{0ν}_{1/2}>4.0\times10^{24}$ yr.

preprint2016arXiv

CUORE-0 detector: design, construction and operation

The CUORE experiment will search for neutrinoless double-beta decay of $^{130}$Te with an array of 988 TeO$_2$ bolometers arranged in 19 towers. CUORE-0, the first tower assembled according to the CUORE procedures, was built and commissioned at Laboratori Nazionali del Gran Sasso, and took data from March 2013 to March 2015. In this paper we describe the design, construction and operation of the CUORE-0 experiment, with an emphasis on the improvements made over a predecessor experiment, Cuoricino. In particular, we demonstrate with CUORE-0 data that the design goals of CUORE are within reach.

preprint2016arXiv

Distributed Data-Processing Pipeline for Mingantu Ultrawide Spectral Radioheliograph

The Chinese Spectral RadioHeliograph (CSRH) is a synthetic aperture radio interferometer built in Inner Mongolia, China. As a solar-dedicated interferometric array, CSRH is capable of producing high quality radio images at frequency range from 400 MHz to 15 GHz with high temporal, spatial, and spectral resolution.To implement high cadence imaging at wide-band and obtain more than 2 order higher multiple frequencies, the implementation of the data processing system for CSRH is a great challenge. It is urgent to build a pipeline for processing massive data of CSRH generated every day. In this paper, we develop a high performance distributed data processing pipeline (DDPP) built on the OpenCluster infrastructure for processing CSRH observational data including data storage, archiving, preprocessing, image reconstruction, deconvolution, and real-time monitoring. We comprehensively elaborate the system architecture of the pipeline and the implementation of each subsystem. The DDPP is automatic, robust, scalable and manageable. The processing performance under multi computers parallel and GPU hybrid system meets the requirements of CSRH data processing. The study presents an valuable reference for other radio telescopes especially aperture synthesis telescopes, and also gives an valuable contribution to the current and/or future data intensive astronomical observations.

preprint2015arXiv

CUORE-0 results and prospects for the CUORE experiment

With 741 kg of TeO2 crystals and an excellent energy resolution of 5 keV (0.2%) at the region of interest, the CUORE (Cryogenic Underground Observatory for Rare Events) experiment aims at searching for neutrinoless double beta decay of 130Te with unprecedented sensitivity. Expected to start data taking in 2015, CUORE is currently in an advanced construction phase at LNGS. CUORE projected neutrinoless double beta decay half-life sensitivity is 1.6E26 y at 1 sigma (9.5E25 y at the 90% confidence level), in five years of live time, corresponding to an upper limit on the effective Majorana mass in the range 40-100 meV (50-130 meV). Further background rejection with auxiliary bolometric detectors could improve CUORE sensitivity and competitiveness of bolometric detectors towards a full analysis of the inverted neutrino mass hierarchy. CUORE-0 was built to test and demonstrate the performance of the upcoming CUORE experiment. It consists of a single CUORE tower (52 TeO2 bolometers of 750 g each, arranged in a 13 floor structure) constructed strictly following CUORE recipes both for materials and assembly procedures. An experiment its own, CUORE-0 is expected to reach a sensitivity to the neutrinoless double beta decay half-life of 130Te around 3E24 y in one year of live time. We present an update of the data, corresponding to an exposure of 18.1 kg y. An analysis of the background indicates that the CUORE performance goal is satisfied while the sensitivity goal is within reach.

preprint2015arXiv

Search for Neutrinoless Double-Beta Decay of $^{130}$Te with CUORE-0

We report the results of a search for neutrinoless double-beta decay in a 9.8~kg$\cdot$yr exposure of $^{130}$Te using a bolometric detector array, CUORE-0. The characteristic detector energy resolution and background level in the region of interest are $5.1\pm 0.3{\rm~keV}$ FWHM and $0.058 \pm 0.004\,(\mathrm{stat.})\pm 0.002\,(\mathrm{syst.})$~counts/(keV$\cdot$kg$\cdot$yr), respectively. The median 90%~C.L. lower-limit sensitivity of the experiment is $2.9\times 10^{24}~{\rm yr}$ and surpasses the sensitivity of previous searches. We find no evidence for neutrinoless double-beta decay of $^{130}$Te and place a Bayesian lower bound on the decay half-life, $T^{0ν}_{1/2}>$~$ 2.7\times 10^{24}~{\rm yr}$ at 90%~C.L. Combining CUORE-0 data with the 19.75~kg$\cdot$yr exposure of $^{130}$Te from the Cuoricino experiment we obtain $T^{0ν}_{1/2} > 4.0\times 10^{24}~\mathrm{yr}$ at 90%~C.L.~(Bayesian), the most stringent limit to date on this half-life. Using a range of nuclear matrix element estimates we interpret this as a limit on the effective Majorana neutrino mass, $m_{ββ}< 270$ -- $760~\mathrm{meV}$.

preprint2015arXiv

Searching for neutrinoless double-beta decay of $^{130}$Te with CUORE

Neutrinoless double-beta ($0νββ$) decay is a hypothesized lepton-number-violating process that offers the only known means of asserting the possible Majorana nature of neutrino mass. The Cryogenic Underground Observatory for Rare Events (CUORE) is an upcoming experiment designed to search for $0νββ$ decay of $^{130}$Te using an array of 988 TeO$_2$ crystal bolometers operated at 10 mK. The detector will contain 206 kg of $^{130}$Te and have an average energy resolution of 5 keV; the projected $0νββ$ decay half-life sensitivity after five years of live time is $1.6\times 10^{26}$ y at $1σ$ ($9.5\times10^{25}$ y at the 90% confidence level), which corresponds to an upper limit on the effective Majorana mass in the range 40--100 meV (50--130 meV). In this paper we review the experimental techniques used in CUORE as well as its current status and anticipated physics reach.

preprint2015arXiv

Status of the CUORE and results from the CUORE-0 neutrinoless double beta decay experiments

CUORE is a 741 kg array of TeO2 bolometers for the search of neutrinoless double beta decay of 130Te. The detector is being constructed at the Laboratori Nazionali del Gran Sasso, Italy, where it will start taking data in 2015. If the target background of 0.01 counts/keV/kg/y will be reached, in five years of data taking CUORE will have a 1 sigma half life sensitivity of 10E26 y. CUORE-0 is a smaller experiment constructed to test and demonstrate the performances expected for CUORE. The detector is a single tower of 52 CUORE-like bolometers that started taking data in spring 2013. The status and perspectives of CUORE will be discussed, and the first CUORE-0 data will be presented.

preprint2015arXiv

The CUORE and CUORE-0 Experiments at Gran Sasso

The Cryogenic Underground Observatory for Rare Events (CUORE) is an experiment to search for neutrinoless double beta decay ($0νββ$) in $^{130}$Te and other rare processes. CUORE is a cryogenic detector composed of 988 TeO$_2$ bolometers for a total mass of about 741 kg. The detector is being constructed at the Laboratori Nazionali del Gran Sasso, Italy, where it will start taking data in 2015. If the target background of 0.01 counts/(keV$\cdot$kg$\cdot$y) will be reached, in five years of data taking CUORE will have an half life sensitivity around $1\times 10^{26}$ y at 90\% C.L. As a first step towards CUORE a smaller experiment CUORE-0, constructed to test and demonstrate the performances expected for CUORE, has been assembled and is running. The detector is a single tower of 52 CUORE-like bolometers that started taking data in spring 2013. The status and perspectives of CUORE will be discussed, and the first CUORE-0 data will be presented.

preprint2014arXiv

CeLAND: search for a 4th light neutrino state with a 3 PBq 144Ce-144Pr electron antineutrino generator in KamLAND

The reactor neutrino and gallium anomalies can be tested with a 3-4 PBq (75-100 kCi scale) 144Ce-144Pr antineutrino beta-source deployed at the center or next to a large low-background liquid scintillator detector. The antineutrino generator will be produced by the Russian reprocessing plant PA Mayak as early as 2014, transported to Japan, and deployed in the Kamioka Liquid Scintillator Anti-Neutrino Detector (KamLAND) as early as 2015. KamLAND's 13 m diameter target volume provides a suitable environment to measure the energy and position dependence of the detected neutrino flux. A characteristic oscillation pattern would be visible for a baseline of about 10 m or less, providing a very clean signal of neutrino disappearance into a yet-unknown, sterile neutrino state. This will provide a comprehensive test of the electron dissaperance neutrino anomalies and could lead to the discovery of a 4th neutrino state for Delta_m^2 > 0.1 eV^2 and sin^2(2theta) > 0.05.

preprint2014arXiv

CUORE and beyond: bolometric techniques to explore inverted neutrino mass hierarchy

The CUORE (Cryogenic Underground Observatory for Rare Events) experiment will search for neutrinoless double beta decay of $^{130}$Te. With 741 kg of TeO$_2$ crystals and an excellent energy resolution of 5 keV (0.2%) at the region of interest, CUORE will be one of the most competitive neutrinoless double beta decay experiments on the horizon. With five years of live time, CUORE projected neutrinoless double beta decay half-life sensitivity is $1.6\times 10^{26}$ y at $1σ$ ($9.5\times10^{25}$ y at the 90% confidence level), which corresponds to an upper limit on the effective Majorana mass in the range 40--100 meV (50--130 meV). Further background rejection with auxiliary light detector can significantly improve the search sensitivity and competitiveness of bolometric detectors to fully explore the inverted neutrino mass hierarchy with $^{130}$Te and possibly other double beta decay candidate nuclei.

preprint2014arXiv

Exploring the Neutrinoless Double Beta Decay in the Inverted Neutrino Hierarchy with Bolometric Detectors

Neutrinoless double beta decay (0nubb) is one of the most sensitive probes for physics beyond the Standard Model, providing unique information on the nature of neutrinos. In this paper we review the status and outlook for bolometric 0nubb decay searches. We summarize recent advances in background suppression demonstrated using bolometers with simultaneous readout of heat and light signals. We simulate several configurations of a future CUORE-like bolometer array which would utilize these improvements and present the sensitivity reach of a hypothetical next-generation bolometric 0nubb experiment. We demonstrate that a bolometric experiment with the isotope mass of about 1 ton is capable of reaching the sensitivity to the effective Majorana neutrino mass (|mee|) of order 10-20 meV, thus completely exploring the so-called inverted neutrino mass hierarchy region. We highlight the main challenges and identify priorities for an R&D program addressing them.

preprint2014arXiv

Initial performance of the CUORE-0 experiment

CUORE-0 is a cryogenic detector that uses an array of tellurium dioxide bolometers to search for neutrinoless double-beta decay of ^{130}Te. We present the first data analysis with 7.1 kg y of total TeO_2 exposure focusing on background measurements and energy resolution. The background rates in the neutrinoless double-beta decay region of interest (2.47 to 2.57 MeV) and in the α background-dominated region (2.70 to 3.90 MeV) have been measured to be 0.071 \pm 0.011 and 0.019 \pm 0.002 counts/keV/kg/y, respectively. The latter result represents a factor of 6 improvement from a predecessor experiment, Cuoricino. The results verify our understanding of the background sources in CUORE-0, which is the basis of extrapolations to the full CUORE detector. The obtained energy resolution (full width at half maximum) in the region of interest is 5.7 keV. Based on the measured background rate and energy resolution in the region of interest, CUORE-0 half-life sensitivity is expected to surpass the observed lower bound of Cuoricino with one year of live time.

preprint2013arXiv

Sensitivity and Discovery Potential of CUORE to Neutrinoless Double-Beta Decay

We present a study of the sensitivity and discovery potential of CUORE, a bolometric double-beta decay experiment under construction at the Laboratori Nazionali del Gran Sasso in Italy. Two approaches to the computation of experimental sensitivity for various background scenarios are presented, and an extension of the sensitivity formulation to the discovery potential case is also discussed. Assuming a background rate of 10^-2 cts/(keV kg y), we find that, after 5 years of live time, CUORE has a 1 sigma sensitivity to the neutrinoless double-beta decay half-life of T_1/2(1 sigma) = 1.6 \times 10^26 y and thus a potential to probe the effective Majorana neutrino mass down to 40-100 meV; the sensitivity at 1.64 sigma, which corresponds to 90% C.L., will be T_1/2(1.64 sigma) = 9.5 \times 10^25 y. This range is compared with the claim of observation of neutrinoless double-beta decay in 76Ge and the preferred range of the neutrino mass parameter space from oscillation results.

preprint2013arXiv

Study of the electromagnetic background in the XENON100 experiment

The XENON100 experiment, located at the Laboratori Nazionali del Gran Sasso (LNGS), aims to directly detect dark matter in the form of Weakly Interacting Massive Particles (WIMPs) via their elastic scattering off xenon nuclei. We present a comprehensive study of the predicted electronic recoil background coming from radioactive decays inside the detector and shield materials, and intrinsic contamination. Based on GEANT4 Monte Carlo simulations using a detailed geometry together with the measured radioactivity of all detector components, we predict an electronic recoil background in the WIMP-search energy range (0-100 keV) in the 30 kg fiducial mass of less than 10e-2 events/(kg-day-keV), consistent with the experiment's design goal. The predicted background spectrum is in very good agreement with the data taken during the commissioning of the detector, in Fall 2009.

preprint2012arXiv

Bending and wrinkling as competing relaxation pathways for strained free-hanging films

An equilibrium phase diagram for the shape of compressively strained free-hanging films is developed by total strain energy minimization. For small strain gradients Δε, the film wrinkles, while for sufficiently large Δε, a phase transition from wrinkling to bending occurs. We consider competing relaxation mechanisms for free-hanging films, which have rolled up into tube structures, and we provide an upper limit for the maximum achievable number of tube rotations.

preprint2012arXiv

The distributed Slow Control System of the XENON100 Experiment

The XENON100 experiment, in operation at the Laboratori Nazionali del Gran Sasso (LNGS) in Italy, was designed to search for evidence of dark matter interactions inside a volume of liquid xenon using a dual-phase time projection chamber. This paper describes the Slow Control System (SCS) of the experiment with emphasis on the distributed architecture as well as on its modular and expandable nature. The system software was designed according to the rules of Object-Oriented Programming and coded in Java, thus promoting code reusability and maximum flexibility during commissioning of the experiment. The SCS has been continuously monitoring the XENON100 detector since mid 2008, remotely recording hundreds of parameters on a few dozen instruments in real time, and setting emergency alarms for the most important variables.

preprint2012arXiv

The XENON100 Dark Matter Experiment

The XENON100 dark matter experiment uses liquid xenon (LXe) in a time projection chamber (TPC) to search for Xe nuclear recoils resulting from the scattering of dark matter Weakly Interacting Massive Particles (WIMPs). In this paper we present a detailed description of the detector design and present performance results, as established during the commissioning phase and during the first science runs. The active target of XENON100 contains 62 kg of LXe, surrounded by an LXe veto of 99 kg, both instrumented with photomultiplier tubes (PMTs) operating inside the liquid or in Xe gas. The LXe target and veto are contained in a low-radioactivity stainless steel vessel, embedded in a passive radiation shield. The experiment is installed underground at the Laboratori Nazionali del Gran Sasso (LNGS), Italy and has recently published results from a 100 live-days dark matter search. The ultimate design goal of XENON100 is to achieve a spin-independent WIMP-nucleon scattering cross section sensitivity of σ= 2x10^-45 cm^2 for a 100 GeV/c^2 WIMP.

preprint2011arXiv

Dark Matter Results from 100 Live Days of XENON100 Data

We present results from the direct search for dark matter with the XENON100 detector, installed underground at the Laboratori Nazionali del Gran Sasso of INFN, Italy. XENON100 is a two-phase time projection chamber with a 62 kg liquid xenon target. Interaction vertex reconstruction in three dimensions with millimeter precision allows to select only the innermost 48 kg as ultra-low background fiducial target. In 100.9 live days of data, acquired between January and June 2010, no evidence for dark matter is found. Three candidate events were observed in a pre-defined signal region with an expected background of 1.8 +/- 0.6 events. This leads to the most stringent limit on dark matter interactions today, excluding spin-independent elastic WIMP-nucleon scattering cross-sections above 7.0x10^-45 cm^2 for a WIMP mass of 50 GeV/c^2 at 90% confidence level.

preprint2011arXiv

First Dark Matter Results from the XENON100 Experiment

The XENON100 experiment, in operation at the Laboratori Nazionali del Gran Sasso in Italy, is designed to search for dark matter WIMPs scattering off 62 kg of liquid xenon in an ultra-low background dual-phase time projection chamber. In this letter, we present first dark matter results from the analysis of 11.17 live days of non-blind data, acquired in October and November 2009. In the selected fiducial target of 40 kg, and within the pre-defined signal region, we observe no events and hence exclude spin-independent WIMP-nucleon elastic scattering cross-sections above 3.4 x 10^-44 cm^2 for 55 GeV/c^2 WIMPs at 90% confidence level. Below 20 GeV/c^2, this result constrains the interpretation of the CoGeNT and DAMA signals as being due to spin-independent, elastic, light mass WIMP interactions.

preprint2011arXiv

Implications on Inelastic Dark Matter from 100 Live Days of XENON100 Data

The XENON100 experiment has recently completed a dark matter run with 100.9 live-days of data, taken from January to June 2010. Events in a 48kg fiducial volume in the energy range between 8.4 and 44.6 keVnr have been analyzed. A total of three events have been found in the predefined signal region, compatible with the background prediction of (1.8 \pm 0.6) events. Based on this analysis we present limits on the WIMP-nucleon cross section for inelastic dark matter. With the present data we are able to rule out the explanation for the observed DAMA/LIBRA modulation as being due to inelastic dark matter scattering off iodine at a 90% confidence level.

preprint2011arXiv

Likelihood Approach to the First Dark Matter Results from XENON100

Many experiments that aim at the direct detection of Dark Matter are able to distinguish a dominant background from the expected feeble signals, based on some measured discrimination parameter. We develop a statistical model for such experiments using the Profile Likelihood ratio as a test statistic in a frequentist approach. We take data from calibrations as control measurements for signal and background, and the method allows the inclusion of data from Monte Carlo simulations. Systematic detector uncertainties, such as uncertainties in the energy scale, as well as astrophysical uncertainties, are included in the model. The statistical model can be used to either set an exclusion limit or to make a discovery claim, and the results are derived with a proper treatment of statistical and systematic uncertainties. We apply the model to the first data release of the XENON100 experiment, which allows to extract additional information from the data, and place stronger limits on the spin-independent elastic WIMP-nucleon scattering cross-section. In particular, we derive a single limit, including all relevant systematic uncertainties, with a minimum of 2.4x10^-44 cm^2 for WIMPs with a mass of 50 GeV/c^2.

preprint2011arXiv

Material screening and selection for XENON100

Results of the extensive radioactivity screening campaign to identify materials for the construction of XENON100 are reported. This Dark Matter search experiment is operated underground at Laboratori Nazionali del Gran Sasso (LNGS), Italy. Several ultra sensitive High Purity Germanium detectors (HPGe) have been used for gamma ray spectrometry. Mass spectrometry has been applied for a few low mass plastic samples. Detailed tables with the radioactive contaminations of all screened samples are presented, together with the implications for XENON100.