Researcher profile

Xun Jia

Xun Jia contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
7works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2026arXiv

Human-like AI-based Auto-Field-in-Field Whole-Brain Radiotherapy Treatment Planning With Conversation Large Language Model Feedback

Whole-brain radiotherapy (WBRT) is a common treatment due to its simplicity and effectiveness. While automated Field-in-Field (Auto-FiF) functions assist WBRT planning in modern treatment planning systems, it still requires manual approaches for optimal plan generation including patient-specific hyperparameters definition and plan refinement based on quality feedback. This study introduces an automated WBRT planning pipeline that integrates a deep learning (DL) Hyperparameter Prediction model for patient-specific parameter generation and a large-language model (LLM)-based conversational interface for interactive plan refinement. The Hyperparameter Prediction module was trained on 55 WBRT cases using geometric features of clinical target volume (CTV) and organs at risk (OARs) to determine optimal Auto-FiF settings in RayStation treatment planning system. Plans were generated under predicted hyperparameters. For cases in which the generated plan was suboptimal, quality feedback via voice input was captured by a Conversation module, transcribed using Whisper, and interpreted by GPT-4o to adjust planning settings. Plan quality was evaluated in 15 independent cases using clinical metrics and expert review, and model explainability was supported through analysis of feature importance. Fourteen of 15 DL-generated plans were clinically acceptable. Normalized to identical CTV D95% as the clinical plans, the DL-generated and clinical plans showed no statistically significant differences in doses to the eyes, lenses, or CTV dose metrics D1% and D99%. The DL-based planning required under 1 minute of computation and achieved total workflow execution in approximately 7 minutes with a single mouse click, compared to 15 minutes for manual planning. In cases requiring adjustment, the Conversational module successfully improved dose conformity and hotspot reduction.

preprint2023arXiv

Joint k-TE Space Image Reconstruction and Data Fitting for T2 Mapping

Objectives: To develop a joint k-TE reconstruction algorithm to reconstruct the T2-weighted (T2W) images and T2 map simultaneously. Materials and Methods: The joint k-TE reconstruction model was formulated as an optimization problem subject to a self-consistency condition of the exponential decay relationship between the T2W images and T2 map. The objective function included a data fidelity term enforcing the agreement between the solution and the measured k-space data, together with a spatial regularization term on image properties of the T2W images. The optimization problem was solved using Alternating-Direction Method of Multipliers (ADMM). We tested the joint k-TE method in phantom data and healthy volunteer scans with fully-sampled and under-sampled k-space lines. Image quality of the reconstructed T2W images and T2 map, and the accuracy of T2 measurements derived by the joint k- TE and the conventional signal fitting method were compared. Results: The proposed method improved image quality with reduced noise and less artifacts on both T2W images and T2 map, and increased measurement consistency in T2 relaxation time measurements compared with the conventional method in all data sets. Conclusions: The proposed reconstruction method outperformed the conventional magnitude image-based signal fitting method in image quality and stability of quantitative T2 measurements

preprint2022arXiv

Top-level Design and Simulated Performance of the First Portable CT-MR scanner

Multi-modality imaging hardware can be integrated in a single gantry to collect diverse datasets for complementary information and spatiotemporal correlation, with excellent examples including PET-CT and PET-MRI. However, there is no CT-MRI prototype up to today due to technical challenges and associated cost-benefit considerations. Thanks to the rapid development of medical imaging, it becomes feasible now to integrate cost-effective CT and MRI imagers together for portability, popularity, and point of care. In this paper, we present the top-level design of the first portable CT-MRI system and evaluate its imaging performance via realistic numerical simulations. In this CT-MRI system, the magnet made of two NdFeB rings of about 40.0 cm radius forms a magnetic field of about 57 mT at the isocenter and has a gap of 11.3 cm to accommodate the rotating CT gantry. The targeted MR imaging field of view (FOV) is a sphere of ~15 cm in diameter and that of CT is approximately 20 cm diameter in axial direction and 5 cm in longitudinal direction. Our results show a great potential of such a hybrid system. The proposed CT-MRI system will be valuable in applications such as imaging in underdeveloped countries, disaster scenes and battle fields.

preprint2021arXiv

Noise Entangled GAN For Low-Dose CT Simulation

We propose a Noise Entangled GAN (NE-GAN) for simulating low-dose computed tomography (CT) images from a higher dose CT image. First, we present two schemes to generate a clean CT image and a noise image from the high-dose CT image. Then, given these generated images, an NE-GAN is proposed to simulate different levels of low-dose CT images, where the level of generated noise can be continuously controlled by a noise factor. NE-GAN consists of a generator and a set of discriminators, and the number of discriminators is determined by the number of noise levels during training. Compared with the traditional methods based on the projection data that are usually unavailable in real applications, NE-GAN can directly learn from the real and/or simulated CT images and may create low-dose CT images quickly without the need of raw data or other proprietary CT scanner information. The experimental results show that the proposed method has the potential to simulate realistic low-dose CT images.

preprint2020arXiv

Development of a Real-time Indoor Location System using Bluetooth Low Energy Technology and Deep Learning to Facilitate Clinical Applications

An indoor, real-time location system (RTLS) can benefit both hospitals and patients by improving clinical efficiency through data-driven optimization of procedures. Bluetooth-based RTLS systems are cost-effective but lack accuracy and robustness because Bluetooth signal strength is subject to fluctuation. We developed a machine learning-based solution using a Long Short-Term Memory (LSTM) network followed by a Multilayer Perceptron classifier and a posterior constraint algorithm to improve RTLS performance. Training and validation datasets showed that most machine learning models perform well in classifying individual location zones, although LSTM was most reliable. However, when faced with data indicating cross-zone trajectories, all models showed erratic zone switching. Thus, we implemented a history-based posterior constraint algorithm to reduce the variability in exchange for a slight decrease in responsiveness. This network increases robustness at the expense of latency. When latency is less of a concern, we computed the latency-corrected accuracy which is 100% for our testing data, significantly improved from LSTM without constraint which is 96.2%. The balance between robustness and responsiveness can be considered and adjusted on a case-by-case basis, according to the specific needs of downstream clinical applications. This system was deployed and validated in an academic medical center. Industry best practices enabled system scaling without substantial compromises to performance or cost.

preprint2020arXiv

Experimental and numerical studies on kV scattered x-ray imaging for real-time image guidance in radiation therapy

Motion management is a critical component of image guidance radiotherapy for lung cancer. We previously proposed a scheme using kV scattered x-ray photons for marker-less real-time image guidance in lung cancer radiotherapy. This study reports our recently progress using the photon counting detection technique to demonstrate potential feasibility of this method and using Monte Carlo (MC) simulations and ray-tracing calculations to characterize the performance. In our scheme, a thin slice of x-ray beam was directed to the target and we measured the outgoing scattered photons using a photon counting detector with a parallel-hole collimator to establish the correspondence between detector pixels and scatter positions. Image corrections of geometry, beam attenuation and scattering angle were performed to convert the raw image to the actual image of Compton attenuation coefficient. We set up a MC simulation system using an in-house developed GPU-based MC package modeling the image formation process. We also performed ray-tracing calculations to investigate the impacts of imaging system geometry on resulting image resolution. The experiment demonstrated feasibility of using a photon counting detector to measure scattered x-ray photons and generate the proposed scattered x-ray image. After correction, x-ray scattering image intensity and Compton scattering attenuation coefficient were linearly related, with R2=0.91. Contrast to Noise Ratios of different objects were improved and the values in experimental results and MC simulation results agreed with each other. Ray-tracing calculations revealed the dependence of image resolution on imaging geometry. The image resolution increases with reduced source to object distance and increased collimator height. The study demonstrated potential feasibility of using scattered x-ray imaging as a real-time image guidance method in radiation therapy.

preprint2019arXiv

Incorporating human and learned domain knowledge into training deep neural networks: A differentiable dose volume histogram and adversarial inspired framework for generating Pareto optimal dose distributions in radiation therapy

We propose a novel domain specific loss, which is a differentiable loss function based on the dose volume histogram, and combine it with an adversarial loss for the training of deep neural networks to generate Pareto optimal dose distributions. The mean squared error (MSE) loss, dose volume histogram (DVH) loss, and adversarial (ADV) loss were used to train 4 instances of the neural network model: 1) MSE, 2) MSE+ADV, 3) MSE+DVH, and 4) MSE+DVH+ADV. 70 prostate patients were acquired, and the dose influence arrays were calculated for each patient. 1200 Pareto surface plans per patient were generated by pseudo-randomizing the tradeoff weights (84,000 plans total). We divided the data into 54 training, 6 validation, and 10 testing patients. Each model was trained for 100,000 iterations, with a batch size of 2. The prediction time of each model is 0.052 seconds. Quantitatively, the MSE+DVH+ADV model had the lowest prediction error of 0.038 (conformation), 0.026 (homogeneity), 0.298 (R50), 1.65% (D95), 2.14% (D98), 2.43% (D99). The MSE model had the worst prediction error of 0.134 (conformation), 0.041 (homogeneity), 0.520 (R50), 3.91% (D95), 4.33% (D98), 4.60% (D99). For both the mean dose PTV error and the max dose PTV, Body, Bladder and rectum error, the MSE+DVH+ADV outperformed all other models. All model's predictions have an average mean and max dose error less than 2.8% and 4.2%, respectively. Expert human domain specific knowledge can be the largest driver in the performance improvement, and adversarial learning can be used to further capture nuanced features. The real-time prediction capabilities allow for a physician to quickly navigate the tradeoff space, and produce a dose distribution as a tangible endpoint for the dosimetrist to use for planning. This can considerably reduce the treatment planning time, allowing for clinicians to focus their efforts on challenging cases.