Researcher profile

Xuejun Gu

Xuejun Gu contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2021arXiv

Volumetric dose extension for isodose tuning

Purpose: To develop a model to generate volumetric dose distribution from two isodose surfaces (iso-surfaces), and to interactively tune dose distribution by iso-surface dragging. Methods: We model volumetric dose distribution as analytical extension of two iso-surfaces with the extension variables as distances to iso-surfaces. We built a 3D lookup table (LUT) which are generated based on clinical dose distributions. Two LUT tables store the mean and standard deviation of voxel dose values of clinical doses and binned as distance to 100% iso-surface, reference iso-surface and reference dose level. The process of interactive tuning starts from a given base plan. A user drags iso-surface for a desired carving. Our method responds with tuned dose. The derivation of tuned dose follows two steps. Dose is extended from the two user-desired iso-surfaces (eg.100% and 50%) to the whole patient volume by table lookup, using distances to two iso-surfaces and reference dose level as keys. Then we fine tune the extended dose by a correction strategy utilizing the information of base plan. Results: We validated this method on coplanar VMAT doses of post-operative prostate plans. The LUT was populated by dose distributions of 27 clinical plans. We optimized two plans with different rectum sparing for an independent case to mimic the process of dose tuning. The plan with less rectum sparing is set as base plan. The 50% iso-surface of the more-sparing plan is defined as the desired iso-surface input. The dose output by our method (expansion and correction) agrees with the more-sparing plan obtained by optimization, in terms of gamma (97.2%), DVH and profiles. The overall dose reconstruction time is within two seconds. Conclusion: We developed a distance-to-isosurface based volumetric dose reconstruction method, and applied it to interactive tuning with iso-surface dragging.

preprint2020arXiv

Breast Ultrasound Computer-Aided Diagnosis Using Structure-Aware Triplet Path Networks

Breast ultrasound (US) is an effective imaging modality for breast cancer detec-tion and diagnosis. The structural characteristics of breast lesion play an im-portant role in Computer-Aided Diagnosis (CAD). In this paper, a novel struc-ture-aware triplet path networks (SATPN) was designed to integrate classifica-tion and two image reconstruction tasks to achieve accurate diagnosis on US im-ages with small training dataset. Specifically, we enhance clinically-approved breast lesion structure characteristics though converting original breast US imag-es to BIRADS-oriented feature maps (BFMs) with a distance-transformation coupled Gaussian filter. Then, the converted BFMs were used as the inputs of SATPN, which performed lesion classification task and two unsupervised stacked convolutional Auto-Encoder (SCAE) networks for benign and malignant image reconstruction tasks, independently. We trained the SATPN with an alter-native learning strategy by balancing image reconstruction error and classification label prediction error. At the test stage, the lesion label was determined by the weighted voting with reconstruction error and label prediction error. We com-pared the performance of the SATPN with TPN using original image as input and our previous developed semi-supervised deep learning methods using BFMs as inputs. Experimental results on two breast US datasets showed that SATPN ranked the best among the three networks, with classification accuracy around 93.5%. These findings indicated that SATPN is promising for effective breast US lesion CAD using small datasets.

preprint2020arXiv

Robustness study of noisy annotation in deep learning based medical image segmentation

Partly due to the use of exhaustive-annotated data, deep networks have achieved impressive performance on medical image segmentation. Medical imaging data paired with noisy annotation are, however, ubiquitous, but little is known about the effect of noisy annotation on deep learning-based medical image segmentation. We studied the effects of noisy annotation in the context of mandible segmentation from CT images. First, 202 images of Head and Neck cancer patients were collected from our clinical database, where the organs-at-risk were annotated by one of 12 planning dosimetrists. The mandibles were roughly annotated as the planning avoiding structure. Then, mandible labels were checked and corrected by a physician to get clean annotations. At last, by varying the ratios of noisy labels in the training data, deep learning-based segmentation models were trained, one for each ratio. In general, a deep network trained with noisy labels had worse segmentation results than that trained with clean labels, and fewer noisy labels led to better segmentation. When using 20% or less noisy cases for training, no significant difference was found on the prediction performance between the models trained by noisy or clean. This study suggests that deep learning-based medical image segmentation is robust to noisy annotations to some extent. It also highlights the importance of labeling quality in deep learning

preprint2019arXiv

BIRADS Features-Oriented Semi-supervised Deep Learning for Breast Ultrasound Computer-Aided Diagnosis

Breast ultrasound (US) is an effective imaging modality for breast cancer detection and diagnosis. US computer-aided diagnosis (CAD) systems have been developed for decades and have employed either conventional hand-crafted features or modern automatic deep-learned features, the former relying on clinical experience and the latter demanding large datasets. In this paper, we have developed a novel BIRADS-SDL network that integrates clinically-approved breast lesion characteristics (BIRADS features) into semi-supervised deep learning (SDL) to achieve accurate diagnoses with a small training dataset. Breast US images are converted to BIRADS-oriented feature maps (BFMs) using a distance-transformation coupled with a Gaussian filter. Then, the converted BFMs are used as the input of an SDL network, which performs unsupervised stacked convolutional auto-encoder (SCAE) image reconstruction guided by lesion classification. We trained the BIRADS-SDL network with an alternative learning strategy by balancing reconstruction error and classification label prediction error. We compared the performance of the BIRADS-SDL network with conventional SCAE and SDL methods that use the original images as inputs, as well as with an SCAE that use BFMs as inputs. Experimental results on two breast US datasets show that BIRADS-SDL ranked the best among the four networks, with classification accuracy around 92.00% and 83.90% on two datasets. These findings indicate that BIRADS-SDL could be promising for effective breast US lesion CAD using small datasets.