Researcher profile

Xavier Garcia-Santiago

Xavier Garcia-Santiago contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - Baseline
5works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2021arXiv

Bayesian optimization with improved scalability and derivative information for efficient design of nanophotonic structures

We propose the combination of forward shape derivatives and the use of an iterative inversion scheme for Bayesian optimization to find optimal designs of nanophotonic devices. This approach widens the range of applicability of Bayesian optmization to situations where a larger number of iterations is required and where derivative information is available. This was previously impractical because the computational efforts required to identify the next evaluation point in the parameter space became much larger than the actual evaluation of the objective function. We demonstrate an implementation of the method by optimizing a waveguide edge coupler.

preprint2021arXiv

On enhanced sensing of chiral molecules in optical cavities

The differential response of chiral molecules to incident left- and right- handed circularly polarized light is used for sensing the handedness of molecules. Currently, significant effort is directed towards enhancing weak differential signals from the molecules, with the goal of extending the capabilities of chiral spectrometers to lower molecular concentrations or small analyte volumes. Previously, optical cavities for enhancing vibrational circular dichroism have been introduced. Their enhancements are mediated by helicity-preserving cavity modes which maintain the handedness of light due to their degenerate TE and TM components. In this article, we simplify the design of the cavity, and numerically compare it with the previous one using an improved model for the response of chiral molecules. We use parameters of molecular resonances to show that the cavities are capable of bringing the vibrational circular dichroism signal over the detection threshold of typical spectrometers for concentrations that are one to three orders of magnitude smaller than those needed without the cavities, for a fixed analyte volume. Frequency resolutions of current spectrometers result in enhancements of more than one order (two orders) of magnitude for the new (previous) design. With improved frequency resolution, the new design achieves enhancements of three orders of magnitude. We show that the TE/TM degeneracy in perfectly helicity preserving modes is lifted by factors that are inherent to the cavities. More surprisingly, this degeneracy is also lifted by the molecules themselves due to their lack of electromagnetic duality symmetry, that is, due to the partial change of helicity during the light-molecule interactions.

preprint2020arXiv

Achiral, Helicity Preserving, and Resonant Structures for Enhanced Sensing of Chiral Molecules

We derive a set of design requirements that lead to structures suitable for molecular circular dichroism (CD) enhancement. Achirality of the structure and two suitably selected sequentially incident beams of opposite helicity ensures that the CD signal only depends on the chiral absorption properties of the molecules, and not on the achiral ones. Under this condition, a helicity preserving structure, which prevents the coupling of the two polarization handednesses, maximizes the enhancement of the CD signal for a given ability of the structure to enhance the field. When the achirality and helicity preservation requirements are met, the enhancement of the CD signal is directly related to the enhancement of the field. Next, we design an exemplary structure following the requirements. The considered system is a planar array of silicon cylinders under normally incident plane-wave illumination. Full-wave numerical calculations show that the enhancement of the transmission CD signal is between 6.5 and 3.75 for interaction lengths between 1.25 and 3 times the height of the cylinders.

preprint2020arXiv

Helicity-preserving optical cavity modes for enhanced sensing of chiral molecules

Researchers routinely sense molecules by their infrared vibrational "fingerprint" absorption resonances. In addition, the dominant handedness of chiral molecules can be detected by circular dichroism (CD), the normalized difference between their optical response to incident left- and right- handed circularly polarized light. Here, we introduce a cavity composed of two parallel arrays of helicity-preserving silicon disks that allows to enhance the CD signal by more than two orders of magnitude for a given molecule concentration and given thickness of the cell containing the molecules. The underlying principle is first-order diffraction into helicity-preserving modes with large transverse momentum and long lifetimes. In sharp contrast, in a conventional Fabry-Perot cavity, each reflection flips the handedness of light, leading to large intensity enhancements inside the cavity, yet to smaller CD signals than without the cavity.

preprint2018arXiv

Role of Geometric Shape in Chiral Optics

The distinction of chiral and mirror symmetric objects is straightforward from a geometrical point of view. Since the biological as well as the optical activity of molecules strongly depend on their handedness, chirality has recently attracted high interest in the field of nano-optics. Various aspects of associated phenomena including the influences of internal and external degrees of freedom on the optical response have been discussed. Here, we propose a constructive method to evaluate the possibility of observing any chiral response from an optical scatterer. Based on solely the T-matrix of one enantiomer, planes of minimal chiral response are located and compared to geometric mirror planes. This provides insights into the relation of geometric and optical properties and enables identifying the potential of chiral scatterers for nano-optical experiments.